7

The AISC’s Prequalified Connections document prescribes prequalified structural connections (beam-to-column connections, for example, not to be confused with AWS prequalified welding procedure specifications, or with prequalified joint details). As part of connection prequalification, welding-related issues such as backing removal, weld tab removal, weld metal properties and inspection requirements are prescribed.

AWS D1.8 and Other AWS Standards.

AWS D1.8 supplements AWS D1.1 Structural Welding Code—Steel6. D1.8 does not replace D1.1, and except as modified by D1.8, all of D1.1 still applies when D1.8 is specified. See D1.8, clause 1.1.

AWS D1.8 is intended to be used on steel structures, where D1.1 applies. D1.8 should not, for example, be used to supplement AWS D1.6 Structural Welding Code—Stainless Steel7. See D1.8, clause 1.3.

AWS D1.8 references the AWS A5 Filler Metal Specifications. Of particular interest is the reference to AWS A5.20: 20058 since this specification has incorporated a new supplemental electrode designator, the “-D” suffix. This suffix reflects a concept contained in both FEMA 353 and D1.8, that of high-low heat input testing, discussed later in this manual. It is expected that future editions of AWS A5.29 will include a similar supplemental designator.

AWS D1.8 and Contract Documents .

Contract Documents are used to specify requirements that may modify provisions contained within codes. In the case of D1.8, Contract Documents play an especially important role, since many provisions typically required for buildings designed to resist seismic loading are not specified in D1.8. Rather, D1.8 requires that when such provisions are to apply, the Engineer must specify them in the Contract Documents. Thus, Contract Documents may be used to “customize” requirements around a specific project. The implication is that one project governed by D1.8 may have significantly different requirements from another, because the Contract Documents for the two projects are different.

AWS D1.8 and FEMA 353.

D1.8 and FEMA 353 are totally separate documents, and it would be impossible to impose both provisions to govern a project without creating significant conflict and contradictions. However, qualifications and various tests done to meet the criteria of FEMA 353 may be used to meet similar or identical requirements in D1.8.

Accordingly, such transfer of results is encouraged in D1.8, subject to the Engineer’s approval. For example, the welder qualification test as prescribed in FEMA 353, Appendix B is similar to that specified in D1.8 Annex D, and the D1.8 commentary specifically encourages the Engineer to accept previous welder qualification testing done to FEMA 353 requirements.

www.lincolnelectric.com

Image 7
Contents D1.8 Seismic Supplement Welding Manual Introduction Table of ContentsCustomer Assistance Policy Document UpdatesBackground D1.8 Seismic Supplement Welding Manual Purpose and Use of This Manual SpecificationsAWS D1.8 and Other Specifications AWS D1.8 and Aisc SpecificationsAWS D1.8 and Contract Documents AWS D1.8 and Other AWS StandardsAWS D1.8 and Fema Overview of D1.8 ContentNew Terminology Three Kinds of Welds See D1.8, clauseDifferences between AWS D1.8/D1.8M2005 and AWS D1.8/D1.8M Differences between Fema 353 and AWS D1.8Engineers User’s Guide to AWS D1.8Fabricators and Erectors Structural DetailersWelder Qualification D1.8 Seismic Supplement Welding Manual Filler Metals General Welding Procedure Specifications WPSsFiller Metals Demand Critical Welds Filler Metals All D1.8 WeldsSee D1.8, clause Techniques Regarding Production Welding InspectorsRegarding Welder Qualification Regarding Filler MetalsRegarding the Protected Zone Regarding Structural DetailsLincoln Electric Products D1.8 Seismic Supplement Welding Manual Heat Input Limits for Demand Critical Welds Exposure TestingHeat Input Limits for Demand Critical Welds cont’d Appendices Smaw and Gmaw Certificates of Conformance Additional Certificates Available OnlineMetal-Cored Wire Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Appendix B Intermix Testing D1.8 Seismic Supplement Welding Manual Appendix C Alternative To Production Lot Testing D1.8 Seismic Supplement Welding Manual D1.8 Seismic Supplement Welding Manual D1.8 Seismic Supplement Welding Manual District Sales Offices Automation Division