Lincoln Electric D1.8 manual Exposure Testing, Heat Input Limits for Demand Critical Welds

Page 22

22

D1.8 Seismic Supplement Welding Manual

Exposure Testing:

Lincoln Electric Approved Filler Metal per AWS D1.8/D1.8M:2009, Subclause 6.1.3

TABLE 3: HEAT INPUT LIMITS FOR DEMAND CRITICAL WELDS

.

Diameters .

High Heat Input

Low Heat Input

Exposure Time @.

Product Name

Available

inches avg.

inches avg.

80°F / 80% Relative Humidity

 

 

 

 

 

Filler Metal with 70 ksi Minimum Tensile Strength Requirement per AWS

 

 

 

 

 

Excalibur® 7018 MR

3/32

 

 

 

AWS E7018 H4R

1/8

 

 

 

 

5/32

 

No heat input testing required

Excalibur® 7018-1 MR

3/16

 

 

 

AWS E7018-1 H4R

7/32

 

 

 

 

1/4

 

 

 

Innershield® NR-232

0.068

74

29

1 Week

AWS E71T-8

0.072

73

31

 

5/64

76

32

 

Innershield® NR-233

1/16

74

33

8 Weeks

AWS E71T-8

0.072

67

31

 

 

5/64

86

32

1 Week

Innershield® NR-305

3/32

64

37

1 Week

AWS E70T-6

 

 

 

 

 

 

 

 

 

Innershield® NR-311 Ni

3/32

80

45

AWS E70T7-K2

 

 

 

 

 

 

 

 

 

Outershield® 71 Elite

1/16

65

30

8 Weeks

AWS E71T-1C-H8, E71T-9C-H8

 

 

 

 

 

 

 

 

 

UltraCore® 70C

1/16

79

32

8 Weeks

AWS E70T-1C-H8, E70T-9C-H8

3/32

80

38

 

5/64

80

32

 

UltraCore® 71C

0.045

80

31

8 Weeks

AWS E71T-1C-H8, E71T-9C-H8

0.052

81

28

 

1/16

82

28

8 Weeks

UltraCore® 71A85

0.045

82

28

8 Weeks

AWS E71T-1M-H8, E71T-9M-H8

0.052

81

31

 

1/16

81

28

 

Metalshield® MC-706

0.045

62

34

72 Hours

AWS E70C-6M-H4

1/16

61

34

 

SuperArc® L-50

0.030

 

 

 

AWS ER70S-3

0.035

No heat input testing required No heat input testing required

 

0.045

 

0.052

 

 

 

 

1/16

 

 

 

 

 

 

 

 

www.lincolnelectric.com

Image 22
Contents D1.8 Seismic Supplement Welding Manual Table of Contents IntroductionDocument Updates Customer Assistance PolicyBackground D1.8 Seismic Supplement Welding Manual AWS D1.8 and Aisc Specifications SpecificationsAWS D1.8 and Other Specifications Purpose and Use of This ManualAWS D1.8 and Contract Documents AWS D1.8 and Other AWS StandardsAWS D1.8 and Fema Overview of D1.8 ContentNew Terminology See D1.8, clause Three Kinds of WeldsDifferences between Fema 353 and AWS D1.8 Differences between AWS D1.8/D1.8M2005 and AWS D1.8/D1.8MUser’s Guide to AWS D1.8 EngineersFabricators and Erectors Structural DetailersWelder Qualification D1.8 Seismic Supplement Welding Manual Welding Procedure Specifications WPSs Filler Metals GeneralFiller Metals All D1.8 Welds Filler Metals Demand Critical WeldsSee D1.8, clause Techniques Regarding Filler Metals InspectorsRegarding Welder Qualification Regarding Production WeldingRegarding Structural Details Regarding the Protected ZoneLincoln Electric Products D1.8 Seismic Supplement Welding Manual Exposure Testing Heat Input Limits for Demand Critical WeldsHeat Input Limits for Demand Critical Welds cont’d Appendices Additional Certificates Available Online Smaw and Gmaw Certificates of ConformanceMetal-Cored Wire Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Appendix B Intermix Testing D1.8 Seismic Supplement Welding Manual Appendix C Alternative To Production Lot Testing D1.8 Seismic Supplement Welding Manual D1.8 Seismic Supplement Welding Manual D1.8 Seismic Supplement Welding Manual District Sales Offices Automation Division