12
D1.8 Seismic Supplement Welding Manual
Structural Detailers.
Table 2 provides a list of references to specific D1.8 code provisions of particular interest to the structural detailer:
| TABLE 2: SPECIFIC D1.8 CODE PROVISIONS | |
|
| |
Structural Detail | D1.8 Coverage | |
|
| |
Access Holes | 1.2.1(9), 6.9 | |
|
| |
1.2.1(5), 6.7, 6.8 | ||
|
| |
1.2.1(6), 6.12 | ||
|
| |
Contouring Fillet Welds | 1.2.1(8), 6.8 | |
|
| |
Corner Clips | 4.1 | |
|
| |
Demand Critical Welds | 1.2.1(4), 3.2 | |
|
| |
End Dams | 6.11 | |
|
| |
3.6, 4.1 | ||
|
| |
Protected Zone | 1.2.1(3), 3.3, 6.6, 6.15 | |
|
| |
Reinforcing Fillet Welds | See Contouring Fillet Welds | |
|
| |
Seismic Force Resisting System (SFRS) | 1.2.1(2), 3.1 | |
|
|
|
Tabs |
| 1.2.1(7), 6.10 |
|
| |
Tack Welds | 6.6, 6.16 | |
|
|
|
Tension | Transition Butt Joints | 1.2.1(11) |
|
|
|
Fabricators and Erectors.
Much of D1.8 is directed to the Contractor performing the welding. The various provisions directed toward the Contractor can be grouped into these major categories:
Welder Qualification
Welding Procedure Specifications (WPSs) Filler Metals
Techniques
Welder Qualification
Clause 5 and Annex D of D1.8 are devoted to welder qualification. In addition to meeting the welder qualification requirements of D1.1, welders performing work under D1.8 are required to take the Supplemental Welder Qualification for Restricted Access Welding Test, as prescribed in Annex D, when the production weld involves all of the following:
www.lincolnelectric.com