Lincoln Electric D1.8 manual Heat Input Limits for Demand Critical Welds cont’d

Page 23

D1.8 Seismic Supplement Welding Manual

23

TABLE 3: HEAT INPUT LIMITS FOR DEMAND CRITICAL WELDS (cont’d)

.

Product Name

Diameters . Available (in)

High Heat Input mm(in.) avg.

Low Heat Input mm (in.) avg.

Exposure Time @. 80°F / 80% Relative Humidity

Filler Metal with 70 ksi Minimum Tensile Strength Requirement per AWS

 

 

 

 

 

 

 

SuperArc® L-56

0.025

 

 

 

 

AWS ER70S-6

0.030

 

 

 

 

 

0.035

 

 

 

 

 

0.040

 

 

 

 

 

0.045

 

No heat input testing required

 

0.052

 

 

 

 

 

 

 

1/16

 

 

 

 

 

 

 

 

 

 

SuperArc® L-59

0.035

 

 

 

 

AWS ER70S-6

0.040

 

 

 

 

 

0.045

 

 

 

 

 

0.052

 

 

 

 

 

1/16

 

 

 

 

 

 

 

 

 

 

Lincolnweld® 960/L-61

1/8

65

32

 

AWS F7A2-EM12K

 

 

 

 

 

 

 

 

 

 

 

 

Filler Metal with 80 ksi Minimum Tensile Strength Requirement per AWS

 

 

 

 

 

 

 

Excalibur® 8018-C3

3/32

 

 

 

 

AWS 8018-C3 MR

1/8

 

 

 

 

 

5/32

 

No heat input testing required

 

3/16

 

 

 

 

 

7/32

 

 

 

 

 

1/4

 

 

 

 

 

 

 

 

 

 

UltraCore® 81Ni1A75-H

0.045

80

30

 

16 Weeks

AWS E81T1-Ni1M-H4

0.052

78

30

 

 

1/16

74

30

 

 

UltraCore® 81Ni1C-H

0.045

74

31

 

16 Weeks

AWS E81T1-Ni1C-H4

0.052

80

30

 

 

1/16

78

29

 

 

SuperArc® LA-75

0.035

 

 

 

 

AWS ER80S-Ni1

0.045

 

 

 

 

 

 

 

 

 

 

SuperArc® LA-90

0.035

 

 

 

 

AWS ER80S-D2, ER90S-D2

0.045

 

 

 

 

 

0.052

 

 

 

 

 

1/16

 

 

 

 

 

 

 

No heat input testing required

Pipeliner® 70S-G

0.045

 

 

 

 

 

AWS ER70S-G

 

 

 

 

 

 

 

 

 

 

 

Pipeliner® 80S-G

0.045

 

 

 

 

AWS ER80S-G

 

 

 

 

 

 

 

 

 

 

 

Pipeliner® 80Ni1

0.040

 

 

 

 

AWS ER80S-G

0.047

 

 

 

 

 

 

 

 

 

 

Lincolnweld® 960/LA-85

1/8

65

32

 

AWS F8A2-ENi5-G

 

 

 

 

 

 

 

 

 

 

 

www.lincolnelectric.com

Image 23
Contents D1.8 Seismic Supplement Welding Manual Introduction Table of ContentsCustomer Assistance Policy Document UpdatesBackground D1.8 Seismic Supplement Welding Manual Purpose and Use of This Manual SpecificationsAWS D1.8 and Other Specifications AWS D1.8 and Aisc SpecificationsAWS D1.8 and Fema AWS D1.8 and Other AWS StandardsAWS D1.8 and Contract Documents New Terminology ContentOverview of D1.8 Three Kinds of Welds See D1.8, clauseDifferences between AWS D1.8/D1.8M2005 and AWS D1.8/D1.8M Differences between Fema 353 and AWS D1.8Engineers User’s Guide to AWS D1.8Welder Qualification Structural DetailersFabricators and Erectors D1.8 Seismic Supplement Welding Manual Filler Metals General Welding Procedure Specifications WPSsFiller Metals Demand Critical Welds Filler Metals All D1.8 WeldsSee D1.8, clause Techniques Regarding Production Welding InspectorsRegarding Welder Qualification Regarding Filler MetalsRegarding the Protected Zone Regarding Structural DetailsLincoln Electric Products D1.8 Seismic Supplement Welding Manual Heat Input Limits for Demand Critical Welds Exposure TestingHeat Input Limits for Demand Critical Welds cont’d Appendices Smaw and Gmaw Certificates of Conformance Additional Certificates Available OnlineMetal-Cored Wire Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Appendix B Intermix Testing D1.8 Seismic Supplement Welding Manual Appendix C Alternative To Production Lot Testing D1.8 Seismic Supplement Welding Manual D1.8 Seismic Supplement Welding Manual D1.8 Seismic Supplement Welding Manual District Sales Offices Automation Division