Significant revisions in the second edition are listed below. For more revisions please see pages vii-viii in the AWS D1.8/D1.8M:2009.

Figures 4.1 and 4.2 – New figures added to illustrate detail of the transition of butt joints for unequal thicknesses.

Subclause 6.3.2 – Clarified and corrected diffusible hydrogen requirements for filler metals.

Subclause 6.3.6 – Modified to disallow exemptions from heat input envelope and classification lot testing when lowest anticipated service temperature (LAST) is less than +50°F.

Subclause CA5.2 – Removed the provision that required two passes per layer to fill the test plate. It is now deemed acceptable to use single passes per layer since achieving acceptable results under such conditions is typically more difficult than when split layers are used.

Subclause C6.13 – Revised welder identifications requirements to permit methods other than the use of stamps or marks on the piece.

A User’s Guide to AWS D1.8

Certain portions of D1.8 are more important to some parties than others, depending on their specific role in the construction process. The following is a general summary of sections of particular interest to the various participants in a construction project.

Engineers.

The primary tasks of the Engineer as they relate to D1.8 are contained in Clause 1.2.1, entitled “Engineer’s Responsibilities.” The Engineer must identify, among other items, the following:

Members that comprise the SFRS

Locations of the Protected Zones in members of the SFRS Welds that are Demand Critical

Locations where steel backing is required to be removed

Locations where fillet welds are required when backing is permitted to remain Locations where weld tabs are to be removed

Locations where fillet welds are required to reinforce groove weld, or to improve connection geometry Locations of weld access holes, and their required shape

The Engineer is also required to develop a Quality Assurance Plan (QAP) for the project. AISC Seismic Provisions Annex Q contains a recommended example of a QAP that the D1.8 commentary encourages the Engineer to adopt without modification. See D1.8, clause 1.2.1.

www.lincolnelectric.com

Image 11
Contents D1.8 Seismic Supplement Welding Manual Introduction Table of ContentsCustomer Assistance Policy Document UpdatesBackground D1.8 Seismic Supplement Welding Manual Purpose and Use of This Manual SpecificationsAWS D1.8 and Other Specifications AWS D1.8 and Aisc SpecificationsAWS D1.8 and Fema AWS D1.8 and Other AWS StandardsAWS D1.8 and Contract Documents New Terminology ContentOverview of D1.8 Three Kinds of Welds See D1.8, clauseDifferences between AWS D1.8/D1.8M2005 and AWS D1.8/D1.8M Differences between Fema 353 and AWS D1.8Engineers User’s Guide to AWS D1.8Welder Qualification Structural DetailersFabricators and Erectors D1.8 Seismic Supplement Welding Manual Filler Metals General Welding Procedure Specifications WPSsFiller Metals Demand Critical Welds Filler Metals All D1.8 WeldsSee D1.8, clause Techniques Regarding Production Welding InspectorsRegarding Welder Qualification Regarding Filler MetalsRegarding the Protected Zone Regarding Structural DetailsLincoln Electric Products D1.8 Seismic Supplement Welding Manual Heat Input Limits for Demand Critical Welds Exposure TestingHeat Input Limits for Demand Critical Welds cont’d Appendices Smaw and Gmaw Certificates of Conformance Additional Certificates Available OnlineMetal-Cored Wire Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Appendix B Intermix Testing D1.8 Seismic Supplement Welding Manual Appendix C Alternative To Production Lot Testing D1.8 Seismic Supplement Welding Manual D1.8 Seismic Supplement Welding Manual D1.8 Seismic Supplement Welding Manual District Sales Offices Automation Division