Milwaukee 5223, 5211, 5243 manual Functional Description Grounding, Specifications, Symbology

Page 4

FUNCTIONAL DESCRIPTION

GROUNDING

 

 

7

 

 

Cat. No. 5211

 

 

3"

1

 

6

 

 

2

 

 

 

3

 

 

 

5

 

7

4

 

 

 

 

6

 

 

Cat. No. 5223

1

 

5"

2

 

 

3

 

 

4

 

8

 

 

7

 

 

6

1

 

Cat. No. 5243

1. Trigger

 

6"

2.Motor housing

3.Spindle housing 2 (insulated handle)

WARNING

Improperly connecting the grounding wire can result in the risk of electric shock. Check with a qualified electri- cian if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the tool. Never remove the grounding prong from the plug. Do not use the tool if the cord or plug is damaged. If damaged, have it repaired by a MILWAUKEE service facility before use. If the plug will not fit the outlet, have a proper outlet installed by a qualified electrician.

Grounded Tools:

Tools with Three Prong Plugs

Tools marked “Grounding Required” have a three wire cord and three prong grounding plug. The plug must be connected to a prop- erly grounded outlet (See Figure A). If the tool should electrically malfunction or break down, grounding provides a low resistance path to carry electricity away from the user, reducing the risk of electric shock.

The grounding prong in the plug is connected through the green wire inside the cord to the grounding system in the tool. The green wire in the cord must be the only wire con- nected to the tool's grounding system and must never be attached to an electrically “live” terminal.

Your tool must be plugged into an appropri- ate outlet, properly installed and grounded in accordance with all codes and ordinances. The plug and outlet should look like those in Figure A.

Double Insulated Tools:

Tools with Two Prong Plugs

Tools marked “Double Insulated” do not require grounding. They have a special double insulation system which satisfies OSHA requirements and complies with the applicable standards of Underwriters Laboratories, Inc., the Canadian Standard Association and the National Electrical Code. Double Insulated tools may be used in either of the 120 volt outlets shown in Figures B and C.

4.

Guard assembly clamp

3

 

5.

Faceplate

4

5

 

 

6.Guard assembly

7.Tool rest

8.Spindle Nut

Specifications

Cat.

Volts

Grounding Req. or

No Load

Arbor Size

Wheel Size

Diameter,

Thickness,

No.

AC/DC

Double Insulated

RPM

Threads

Diameter

5211

120

Double Insulated

14500

3/8" - 24

1/2" x 3"

5223

120

Double Insulated

7000

5/8" - 11

1" x 5"

5243

120

Grounding Required

5700

5/8" - 11

1" x 6"

 

 

 

 

 

 

Fig. A

Fig. B

Fig. C

 

Symbology

 

Double Insulated

 

Volts Alternating Current/

 

 

Direct Current

 

 

 

 

 

 

 

 

Underwriters Laboratories, Inc.,

 

No Load Revolutions per

 

United States and Canada

 

Minute (RPM)

 

 

 

 

 

Amps

 

Mexican Safety

 

 

Standards

 

 

 

 

 

 

 

6

7

Image 4
Contents Operators Manual General Power Tool Safety Warnings Work Area Safety Personal Safety Power Tool USE and CareSpecific Safety Rules Electrical SafetyLead from lead-based paint Functional Description Grounding SymbologySpecifications Tool Assembly Extension CordsInstalling Grinding Wheels and Acces- sories Cat. No only Using the Trigger Lock MechanismOperation GrindingMaintenance Five Year Tool Limited Warranty AccessoriesCleaning Maintaining ToolsSécurité DU Lieu DE Travail Sécurité ÉlectriqueSécurité Individuelle Utilisation ET Entretien DE L’OUTIL ÉlectriqueUne certaine distance du lieu de travail immédiat ’assurer que personne ne se tientRègles de sécurité supplémentaires Pictographie Description Fonctionnelle Mise a LA TerreSpécifications Cordons DE Rallonge Montage DE LoutilInstallation des meules et des acces- soires No de cat seul ManiementMeulage Démarrage et arrêt de l’outilAccesoires Avertissement Entretien de l’outilNettoyage RéparationsSeguridad EN EL Área DE Trabajo Seguridad EléctricaSeguridad Personal USO Y Cuidado DE LAS Herramientas EléctricasContragolpe Y Advertencias Relacionadas Especificaciones Descripcion FuncionalSimbología Tierra Extensiones Electricas Advertencia Guías para el uso de cables de exten- siónEnsamblaje DE LA Herramienta Advertencia Operacion Advertencia Arranque y paro de la herramientaCómo usar el mecanismo de bloqueo del gatillo EsmeriladoMantenimiento Garantía Limitada DE Cinco Años Advertencia Accesorios AdvertenciaMantenimiento de las herramientas ReparacionesCanada Service Milwaukee Milwaukee800.729.3878 800.729.3878 fax