PRIMING

PREPARE TO PRIME

1.Lay unit back on its handle so inlet valve is facing up. Fill inlet valve with water or light household oil.

2. Make sure Prime/Spray Knob is in Prime A position and Pressure Knob is turned to the lowest pressure. (Counter clockwise) See Figure 11. Turn unit on.

Inlet Valve Facing Up

PrimeA /Spray B

Knob

Hose Port

Figure 11 - Prime/Spray Knob

3. Increase pressure half turn.

Pressure Control

Knob

Figure 12 - Pressure Control Knob

4.Force the inlet valve to open and close by pushing on it with the eraser end of a pencil or screwdriver, it should move up and down about 1/16 inch. Continue until water or oil is sucked into unit. This will assist in wetting the moving parts and breaking loose any old paint residue. See Figure 13.

Figure 13 - Opening Inlet Valve

5.Put palm of hand over inlet valve and feel for a slight suction while increasing the pressure control to the maximum setting. See Figure 14. If suction is felt go to step 6. If no suction is felt see Cleaning and Servicing Outlet Valve. ( Repeat steps 1 through 5 if necessary.)

Figure 14 - Checking for Suction

6.Turn Pressure Control Knob to minimum pressure and shut off unit.

7. Return unit to upright position.

12

Image 12
Contents 505 Questions? ... Need Help?Specifications General DescriptionSafety Precautions Hazard Prevention Hazard Prevention Do not USE Bleach Extension Cord Grounding InstructionsPressure Relief Procedure SET-UP Assemble CartTools needed Attach TIP to GUN Correct Way Wrong WayAttach Return Hose Attach Paint Hose Attaching High Pressure Hose to GunPriming Prepare to PrimeReturn unit to upright position Attach Suction SET Prime the Pump Do Not Cross threadTurn Sprayer on Spraying Practice FirstSpraying Technique Result of Flexing Wrist While SprayingIf Spray Tip Becomes Clogged Proper Way to Trigger Spray GunTo clean the filter during the painting process Suction Set ScreenClean UP SHORT-TERM/OVERNIGHT StorageShut-down Start-upCleanup Shut DOWN/CLEAN UPCleaning Bucket Fill Inlet Valve With Oil Maintenance Cleaning ValvesRemoving and Cleaning Inlet Valve Cleaning and Servicing Outlet ValvePriming Knob Slippage Erature setOptional Hopper Assembly Cleaning Hopper UnitConverting Sprayer for Hopper Operation Trouble Shooting Problem Cause RemedyProblem Cause Remedy Parts Diagram Final Assembly Parts Diagram Paint Pump Assembly Item Part no Description QTYParts Diagram Suction Set Assembly 0270174 Parts Diagram Optional Hopper Assembly AccessoriesPart Description Number PartDescription NumberParts and Accessories Parts ListLimited Warranty Airless Paint Spray Equipment Wagner Spray Tech Corporation