Craftsman 919.166442 owner manual Extension Cords, Voltage and Circuit Protection

Page 11

Extension Cords

Using extension cords is not recommended. The use of extension cords will cause voltage to drop resulting in power loss to the motor and overheating.

Instead of using an extension cord, increase the working reach of the air hose by attaching another length of hose to its end. Attach additional lengths of hose as needed.

If an extension cord must be used, be sure it is:

a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle that will accept the plug on the product

in good condition

no longer than 50 feet

12 gauge (AWG) or larger. (Wire size increases as gauge number decreases. 10 AWG and 8 AWG may also be used. DO NOT USE 14 OR 16 AWG.)

Voltage and Circuit Protection

Refer to the specification chart for the voltage and minimum branch circuit requirements.

Risk of Unsafe Operation. Certain

air compressors can be operated on a 15 amp circuit if the following conditions are met.

1.Voltage supply to circuit must comply with the National Electrical Code.

2.Circuit is not used to supply any other electrical needs.

3.Extension cords comply with specifications.

4.Circuit is equipped with a

15 amp circuit breaker or 15 amp time delay fuse. NOTE: If compressor is connected to a circuit protected by fuses, use only time delay fuses. Time delay fuses should be marked "D" in Canada and "T" in the US.

If any of the above conditions cannot be met, or if operation of the compressor repeatedly causes interruption of the power, it may be necessary to operate it from a 20 amp circuit. It is not necessary to change the cord set.

11- ENG

A13640

Image 11
Contents AIR Compressor Table of Contents Important Safety Instructions Specification ChartSafety Guidelines Definitions Location away from compressor Spray area. An additional length of hoseExplosion May be required To alter the factory set operating pressures What Could HappenYour specific application To human consumptionDo not reach around protective shrouds Or attempt maintenance until unit hasResult in serious burns Hot for several minutes after operationFire, Inhalation, Damage to Vehicle Surfaces Duty Cycle AccessoriesAccessories GlossaryLocation of the Air Compressor AssemblyInstallation UnpackingVoltage and Circuit Protection Extension CordsDrain Valve OperationKnow Your Air Compressor Description of OperationRisk of Bursting. Too much air How to StopBefore Starting Before Each Start-UpHow to Start To Drain Tank MaintenanceTo Check Safety Valve Customer ResponsibilitiesScrewdriver Open position nothing is visible Service and AdjustmentsTo Replace or Clean Check Valve Outlet Tube Nut Check ValvePump Mounting Screw Gauges Safety Valve Quick Connect Regulator ManifoldTo Replace Regulator Regulator Manifold Hose ClampStorage Troubleshooting Being used Problem Cause Correction Garantía Total DE UN AÑO ContenidoGarantía Lesiones serias Resultar en lesiones menores o Moderadas Definiciones DE Normas DE SeguridadModelo Nº 919.166442Cómo prevenirlo Instrucciones Importantes DE SeguridadGuarde Estas Instrucciones Qué puede occurrir Cómo prevenirlo Advertencia Riesgo de ExplosiónA13640 30- SP Advertencia Riesgo de Caída Qué puede occurrir Advertencia Riesgo de Quemaduras Qué puede occurrirAdvertencia Riesgo de Operación Lasegura Qué puede occurrir Accesorios GlosarioAccesorios Ciclo DE ServicioDesempaque EnsambladoInstalación Cómo Preparar LA UnidadProtección del voltaje y del circuito Cables de extensión eléctricaDescripción de operaciones OperaciónConozca su compresor de aire Procedimiento para el asentamiento Cómo utilizar su unidadAntes de poner en marcha Cómo detenerlaCómo drenar el tanque MantenimientoResponsabilidades del cliente Cómo verificar la válvula de seguridadTubo de salida Tuerca Servicio Y AjustesPara reemplazar o limpiar la válvula de retención Para reemplazar el regulador Almacenaje Problema Causa Corrección Guía DE Diagnóstico DE ProblemasSe utiliza un El motor no funciona 45- SP A13640 A13640 46- SP Contratos de Protección Maestra Master Protection AgreementsSU-HOGARSM MY-HOMESears Parts and Repair Center Canada