Craftsman 919.166442 owner manual How to Stop, Before Starting, Before Each Start-Up

Page 13

Air Compressor Pump (not shown): Compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet.

Check Valve:

 

When the air

 

compressor is

 

operating, the

 

check valve

 

is "open",

 

allowing

 

compressed

 

air to enter

Check Valve

the air tank.

 

When the

 

air compressor reaches "cut-out" pressure, the check valve "closes", allowing air pressure to remain inside the air tank.

How to Use Your Unit

How to Stop:

1.Set the On/Auto/Off lever to "Off".

Before Starting

Break-in instructions

Risk of Unsafe Operation. Serious

damage may result if the following break-in instructions are not closely followed.

This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced.

1.Make sure the On/Auto/Off lever is in the "Off" position.

NOTE: If quick connect is installed, pull coupler back until it clicks to prevent air from escaping through the quick connect.

2.Plug the power cord into the correct branch circuit receptacle. (Refer to "Voltage and Circuit Protection" paragraph in the Installation section of this manual.)

3.Open the drain valve fully (counter-clockwise) to permit air to escape and prevent air pressure build up in the air tank during the break-in period.

4.Move the On/Auto/Off lever to "On/Auto" position. The compressor will start.

5.Run the compressor for 15 minutes. Make sure the drain valve is open and there is minimal air pressure build-up in tank.

6.After 15 minutes, close the drain valve (clockwise). The air receiver will fill to "cut-out" pressure and the motor will stop.

The compressor is now ready for use.

Before Each Start-Up:

1.Place On/Auto/Off lever to "Off".

2.Pull regulator knob out, turn counter-clockwise until it stops. Push knob in to lock in place.

3.Attach hose and accessories. NOTE: The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect.

Risk of Bursting. Too much air

pressure causes a hazardous risk of bursting. Check the manufacturer’s maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.

13- ENG

A13640

Image 13
Contents AIR Compressor Table of Contents Safety Guidelines Definitions Specification ChartImportant Safety Instructions Explosion May be required Spray area. An additional length of hoseLocation away from compressor To alter the factory set operating pressures What Could HappenYour specific application To human consumptionResult in serious burns Or attempt maintenance until unit hasHot for several minutes after operation Do not reach around protective shroudsFire, Inhalation, Damage to Vehicle Surfaces Accessories AccessoriesGlossary Duty CycleInstallation AssemblyUnpacking Location of the Air CompressorVoltage and Circuit Protection Extension CordsKnow Your Air Compressor OperationDescription of Operation Drain ValveBefore Starting How to StopBefore Each Start-Up Risk of Bursting. Too much airHow to Start To Check Safety Valve MaintenanceCustomer Responsibilities To Drain TankTo Replace or Clean Check Valve Service and AdjustmentsOutlet Tube Nut Check Valve Screwdriver Open position nothing is visibleTo Replace Regulator Gauges Safety Valve Quick Connect Regulator ManifoldRegulator Manifold Hose Clamp Pump Mounting ScrewStorage Troubleshooting Being used Problem Cause Correction Garantía ContenidoGarantía Total DE UN AÑO Modelo Nº Definiciones DE Normas DE Seguridad919.166442 Lesiones serias Resultar en lesiones menores o ModeradasGuarde Estas Instrucciones Instrucciones Importantes DE SeguridadCómo prevenirlo Qué puede occurrir Cómo prevenirlo Advertencia Riesgo de ExplosiónA13640 30- SP Advertencia Riesgo de Caída Qué puede occurrir Advertencia Riesgo de Quemaduras Qué puede occurrirAdvertencia Riesgo de Operación Lasegura Qué puede occurrir Accesorios GlosarioCiclo DE Servicio AccesoriosInstalación EnsambladoCómo Preparar LA Unidad DesempaqueProtección del voltaje y del circuito Cables de extensión eléctricaConozca su compresor de aire OperaciónDescripción de operaciones Antes de poner en marcha Cómo utilizar su unidadCómo detenerla Procedimiento para el asentamientoResponsabilidades del cliente MantenimientoCómo verificar la válvula de seguridad Cómo drenar el tanquePara reemplazar o limpiar la válvula de retención Servicio Y AjustesTubo de salida Tuerca Para reemplazar el regulador Almacenaje Problema Causa Corrección Guía DE Diagnóstico DE ProblemasSe utiliza un El motor no funciona 45- SP A13640 A13640 46- SP Contratos de Protección Maestra Master Protection AgreementsSears Parts and Repair Center MY-HOMECanada SU-HOGARSM