Craftsman 919.166442 To Replace Regulator, Gauges Safety Valve Quick Connect Regulator Manifold

Page 17

To Replace Regulator

1.Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section.

2.Unplug unit.

3.Using an adjustable wrench or specified wrench remove the gauges (7/16" wrench), quick connect (13/16" wrench), and safety valve (9/16" wrench) from the regulator manifold.

Gauges

Safety Valve

Quick

Connect

Regulator

Manifold

4.Remove the hose by removing the hose clamp. NOTE: The hose clamp is not reusable. You must purchase a new hose clamp, see the Parts List Manual or purchase a standard hose clamp at a local hardware store.

Regulator

Manifold

Hose Clamp

5.Remove pump mounting screws securing pump (one on each side).

6.Carefully slide pump from brackets and out of the way.

7.Using an adjustable wrench or 5/8" wrench remove the regulator manifold.

Pump Mounting Screw

8.Apply pipe sealant to new regulator manifold and assemble, tighten with wrench.

9.Reapply pipe sealant to gauges, quick connect, and safety valve.

10.Reassemble all components in reverse order of removal. Make sure to orient gauges to read correctly and use wrenches to tighten all components.

17- ENG

A13640

Image 17
Contents AIR Compressor Table of Contents Important Safety Instructions Specification ChartSafety Guidelines Definitions Location away from compressor Spray area. An additional length of hoseExplosion May be required To alter the factory set operating pressures What Could HappenYour specific application To human consumptionResult in serious burns Or attempt maintenance until unit hasHot for several minutes after operation Do not reach around protective shroudsFire, Inhalation, Damage to Vehicle Surfaces Accessories AccessoriesGlossary Duty CycleInstallation AssemblyUnpacking Location of the Air CompressorVoltage and Circuit Protection Extension CordsKnow Your Air Compressor OperationDescription of Operation Drain ValveBefore Starting How to StopBefore Each Start-Up Risk of Bursting. Too much airHow to Start To Check Safety Valve MaintenanceCustomer Responsibilities To Drain TankTo Replace or Clean Check Valve Service and AdjustmentsOutlet Tube Nut Check Valve Screwdriver Open position nothing is visibleTo Replace Regulator Gauges Safety Valve Quick Connect Regulator ManifoldRegulator Manifold Hose Clamp Pump Mounting ScrewStorage Troubleshooting Being used Problem Cause Correction Garantía Total DE UN AÑO ContenidoGarantía Modelo Nº Definiciones DE Normas DE Seguridad919.166442 Lesiones serias Resultar en lesiones menores o ModeradasCómo prevenirlo Instrucciones Importantes DE SeguridadGuarde Estas Instrucciones Qué puede occurrir Cómo prevenirlo Advertencia Riesgo de ExplosiónA13640 30- SP Advertencia Riesgo de Caída Qué puede occurrir Advertencia Riesgo de Quemaduras Qué puede occurrirAdvertencia Riesgo de Operación Lasegura Qué puede occurrir Accesorios GlosarioCiclo DE Servicio AccesoriosInstalación EnsambladoCómo Preparar LA Unidad DesempaqueProtección del voltaje y del circuito Cables de extensión eléctricaDescripción de operaciones OperaciónConozca su compresor de aire Antes de poner en marcha Cómo utilizar su unidadCómo detenerla Procedimiento para el asentamientoResponsabilidades del cliente MantenimientoCómo verificar la válvula de seguridad Cómo drenar el tanqueTubo de salida Tuerca Servicio Y AjustesPara reemplazar o limpiar la válvula de retención Para reemplazar el regulador Almacenaje Problema Causa Corrección Guía DE Diagnóstico DE ProblemasSe utiliza un El motor no funciona 45- SP A13640 A13640 46- SP Contratos de Protección Maestra Master Protection AgreementsSears Parts and Repair Center MY-HOMECanada SU-HOGARSM