TROUBLESHOOTING

Risk of Unsafe Operation. Unit cycles automatically when power is on. When servicing, you may be exposed to

voltage sources, compressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.

PROBLEM

CAUSE

 

CORRECTION

Excessive tank

Pressure switch does

 

Move On/Auto/Off lever to

pressure - safety

not shut off motor when

 

the "Off" position, if the

valve pops off.

compressor reaches "cut-

 

outfit does not shut off

 

out" pressure.

 

contact a Trained Service

 

 

 

Technician.

 

Pressure switch "cut-out"

 

Contact a Trained Service

 

too high.

 

Technician.

 

 

 

 

 

 

 

Air leaks at

Tube fittings are not tight

 

Tighten fittings where air

fittings.

enough.

 

can be heard escaping.

 

 

 

Check fittings with soapy

 

 

 

water solution. Do Not

 

 

 

Overtighten.

Air leaks in air

Defective air tank.

 

Air tank must be replaced.

tank or at air

 

 

Do not repair the leak.

tank welds.

 

 

 

 

 

Risk of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bursting

 

 

 

 

 

 

 

 

 

Do not drill into, weld or

 

 

 

otherwise modify air tank

 

 

 

or it will weaken. The tank

 

 

 

can rupture or explode.

Air leaks

Leaking seal.

 

Contact a Trained Service

between head

 

 

Technician.

and valve plate.

 

 

 

 

 

 

Air leak from

Possible defect in safety

 

Operate safety valve

safety valve.

valve.

 

manually by pulling on ring.

 

 

 

If valve still leaks, it should

 

 

 

be replaced.

 

 

 

Knocking Noise.

Possible defect in safety

Operate safety valve

 

valve.

manually by pulling on ring.

 

 

If valve still leaks, it should

 

 

be replaced.

 

 

 

 

 

 

 

19- ENG

A13640

Image 19
Contents AIR Compressor Table of Contents Safety Guidelines Definitions Specification ChartImportant Safety Instructions Explosion May be required Spray area. An additional length of hoseLocation away from compressor To alter the factory set operating pressures What Could HappenYour specific application To human consumptionDo not reach around protective shrouds Or attempt maintenance until unit hasResult in serious burns Hot for several minutes after operationFire, Inhalation, Damage to Vehicle Surfaces Duty Cycle AccessoriesAccessories GlossaryLocation of the Air Compressor AssemblyInstallation UnpackingVoltage and Circuit Protection Extension CordsDrain Valve OperationKnow Your Air Compressor Description of OperationRisk of Bursting. Too much air How to StopBefore Starting Before Each Start-UpHow to Start To Drain Tank MaintenanceTo Check Safety Valve Customer ResponsibilitiesScrewdriver Open position nothing is visible Service and AdjustmentsTo Replace or Clean Check Valve Outlet Tube Nut Check ValvePump Mounting Screw Gauges Safety Valve Quick Connect Regulator ManifoldTo Replace Regulator Regulator Manifold Hose ClampStorage Troubleshooting Being used Problem Cause Correction Garantía ContenidoGarantía Total DE UN AÑO Lesiones serias Resultar en lesiones menores o Moderadas Definiciones DE Normas DE SeguridadModelo Nº 919.166442Guarde Estas Instrucciones Instrucciones Importantes DE SeguridadCómo prevenirlo Qué puede occurrir Cómo prevenirlo Advertencia Riesgo de ExplosiónA13640 30- SP Advertencia Riesgo de Caída Qué puede occurrir Advertencia Riesgo de Quemaduras Qué puede occurrirAdvertencia Riesgo de Operación Lasegura Qué puede occurrir Accesorios GlosarioAccesorios Ciclo DE ServicioDesempaque EnsambladoInstalación Cómo Preparar LA UnidadProtección del voltaje y del circuito Cables de extensión eléctricaConozca su compresor de aire OperaciónDescripción de operaciones Procedimiento para el asentamiento Cómo utilizar su unidadAntes de poner en marcha Cómo detenerlaCómo drenar el tanque MantenimientoResponsabilidades del cliente Cómo verificar la válvula de seguridadPara reemplazar o limpiar la válvula de retención Servicio Y AjustesTubo de salida Tuerca Para reemplazar el regulador Almacenaje Problema Causa Corrección Guía DE Diagnóstico DE ProblemasSe utiliza un El motor no funciona 45- SP A13640 A13640 46- SP Contratos de Protección Maestra Master Protection AgreementsSU-HOGARSM MY-HOMESears Parts and Repair Center Canada