Porter-Cable CF6131 instruction manual How to Stop, Before Starting Before Each Start-Up

Page 11
Drain
Valve

Air Compressor Pump (not shown): Compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet.

Drain Valve: The drain valve is located at the base of the air tank and is used to drain condensation at the end of each use.

Check Valve: When the air compressor is operating, the check valve is "open", allowing compressed air to enter

the air tank. When the air compressor reaches "cut-out"

pressure, the check valve "closes", allowing air pressure to remain inside the air tank.

Motor Overload Protector (not shown): The motor has a thermal overload protector. If the motor overheats for any reason, the overload protector will shut off the motor. The motor must be allowed to cool down before restarting. To restart:

1.Set the On/Off lever to "Off" and unplug unit.

2.Allow the motor to cool.

3.Plug the power cord into the correct branch circuit receptacle.

4.Set the Auto/Off lever to "On" position.

Check Valve

How to Use Your Unit

How to Stop

Set the On/Off switch to "Off".

Before Starting

Do not operate this unit until you read this instruction manual for safety, operation and maintenance instructions.

Before Each Start-Up

1.Set the On/Off switch to "Off".

2.Plug the power cord into the correct branch circuit receptacle. (Refer to Voltage and Circuit Protection paragraph in the Installation section of this manual.)

3.Turn the regulator knob counterclockwise to set the outlet pressure to zero.

4.Attach hose and accessories.

Risk of unsafe operation. Firmly grasp air hose in hand when installing or disconnecting to prevent hose whip.

Risk of unsafe operation. Do not use damaged or worn acces-

sories.

NOTE: The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect socket.

Risk of Bursting. Too much air pressure causes a hazardous risk of bursting. Check the manufacturer’s maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.

Risk of property damage. Compressed air from the unit may contain water­ condensation and oil mist. Do not spray unfil­tered­ air at an item that could be damaged by moisture. Some air tools and accessories may require filtered air. Read the instruc­tions­ for the air tools and accessories.

11 - ENG

Image 11
Contents CF6131 Hazard Safety Guidelines DefinitionsImportant Safety Instructions Risk to Breathing Asphyxiation What can happen How to prevent itRisk of Bursting Attachments & accessoriesRisk of Electrical Shock Tires Over inflation of tires couldResult in serious injury Property damageRisk of Unsafe Operation Risk of Hot surfacesRisk from Moving Parts Model No CF6131 Risk of Falling What can happen How to prevent itRisk from noise Glossary AccessoriesAssembly InstallationVoltage and Circuit Protection Extension CordsDescription of Operation OperationKnow Your Air Compressor Before Starting Before Each Start-Up How to StopCustomer Responsibilities MaintenanceTo Check Safety Valve How to StartSee Replacement Parts in the Service sec Service and AdjustmentsTo Replace or Clean Check Valve Unplug unit Quick connect, and safety valveStorage To Replace RegulatorReplacement Parts Service and Repairs ServiceProblem Cause Correction TroubleshootingDescription Overload Protection Full One Year Warranty Risque d’explosion ou d’incendie Mesures DE Sécurité DéfinitionsConsignes DE Sécurité Importantes Indique un dangerRisque Repiratoire Asphyxie Placer par un nouveau réservoir d’air Risque d’ÉclatementBlessures graves et des Accessoires Pneus Des pneus surgonflés Pourraient provoquer desDirectives relatives à la mise Mise à la terre électrique leRisque associÉ À utilisation Risque associÉ auxPiÈces mobiles Modèle no CF6131 SpecificationsLexique Risque associÉ au bruitDéballage Cycle DE ServiceAccessoires AssemblageRallonges Directives DE Mise À LA TerreDescription du fonctionnement UtilisationProtection contre la surtension et protection du circuit Familiarisez-vous avec votre compresseur dairArrêt de lappareil Utilisation de lappareilCondensation après chaque utilisation La soupape de retenue est « ouverte », permettant àMise en marche Vidange du réservoir EntretienResponsabilités du client Vérification de la soupape de sûretéEntretien ET Réglages Remplacement ou nettoyage de la soupape de retenueVidange du réservoir de la section Pour remplacer le régulateuPièces DE Rechange Entretien ET Réparation RangementDépannage Remarque Ajustez Intitulé «Description duFonctionnement» de la Surcharge du moteur Garantie complète d’un 1 an Peligro Definiciones DE Normas DE SeguridadInstrucciones Importantes DE Seguridad Riesgo Respiratorio asfixia Elementos y accesorios Riesgo de explosiónDaño a la propiedad Neumáticos El inflado excesivo deLos neumáticos podría Causar lesiones graves yRiesgo por piezas móviles Riesgo DE superficies calientesRiesgo DE Caídas Riesgo de operación inseguraModelo Nº CF6131 Cuadro DE EspecificacionesGlosario Riesgo por ruidosInstalación Ciclo DE ServicioAccesorios EnsambladoProtección del voltaje y del circuito Cables de extensión eléctricaDescripción de operaciones OperaciónConozca su compresor de aire Antes de poner en marcha Cómo utilizar su unidadProtector de sobrecalentamiento del motor Cómo detenerlaResponsabilidades del cliente MantenimientoCómo drenar el tanque Cómo verificar la válvula de seguridadPara reemplazar el regulador Servicio Y AjustesPara reemplazar o limpiar la válvula retención Almacenaje Piezas DE Repuesto Mantenimiento Y Reparaciones ServicioCorrección Guía DE Diagnóstico DE ProblemasLas instrucciones de Sobrecalentamiento Consulte Protector deIdentificación DEL Producto Sello o firma del Distribuidor Póliza de GarantíaGarantía completa de un año Para Otras Localidades Page Page Highway 45 North Jackson, TN 888