Bryant 581B Furnace Section, Loss-Of-Charge Switch/Low-Pressure, Freeze Protection Thermostat

Page 7

Table 1 — Physical Data — 581B036-072 (cont)

UNIT SIZE 581B

 

036

048

 

060

072

FURNACE SECTION

 

 

 

 

 

 

Rollout Switch Cutout Temp (F)†

 

195

195

 

195

195

Burner Orifice Diameter (in. ...drill size)**

 

 

 

 

 

 

Natural Gas — Std

071/072

.113...33

.113...33

 

.113...33

.113...33

 

114/115

.113...33

.113...33

 

.113...33

.113...33

 

149/150

.129...30

 

.129...30

.129...30

 

060N

.102...38

.102...38

 

.102...38

 

090N

.102...38

.102...38

 

.102...38

 

120N

.116...32

 

.116...32

Liquid Propane — Alt††

071/072

.089...43

.089...43

 

.089...43

.089...43

 

114/115

.089...43

.089...43

 

.089...43

.089...43

 

149/150

.102...38

 

.102...38

.102...38

 

060N

.082...45

.082...45

 

.082...45

 

090N

.082...45

.082...45

 

.082...45

Thermostat Heat Anticipator Setting (amps)

120N

.094...42

 

.094...42

 

 

 

 

 

 

208/230/460 v

 

 

 

 

 

 

First Stage

 

.14

.14

 

.14

.14

Second Stage

 

.14

.14

 

.14

.14

Gas Input (Btuh)

 

 

 

 

 

 

First Stage/Second Stage (3-phase units)

072

50,000/ 72,000

50,000/ 72,000

 

50,000/ 72,000

50,000/ 72,000

 

115

82,000/115,000

82,000/115,000

 

82,000/115,000

82,000/115,000

 

150

120,000/150,000

 

120,000/150,000

120,000/150,000

 

071II

—/ 72,000

—/ 72,000

 

—/ 72,000

 

114II

—/115,000

—/115,000

 

—/115,000

 

149II

—/150,000

 

—/150,000

 

060N***

—/ 60,000

—/ 60,000

 

—/ 60,000

 

090N***

—/ 90,000

—/ 90,000

 

—/ 90,000

 

120N***

—/120,000

 

—/120,000

Efficiency (Steady State) (%)

072

82.8

82.8

 

82.8

82

 

115

80

81

 

81

81

 

150

80.4

 

80.4

80

 

071

82

82

 

82

 

114

80

81

 

81

 

149

80

 

80

 

060N

80.2

80.2

 

80.2

 

090N

81

81

 

81

 

120N

80.7

 

80.7

Temperature Rise Range

072

25-55

25-55

 

25-55

25-55

 

115

55-85

35-65

 

35-65

35-65

 

150

50-80

 

50-80

50-80

 

071

25-55

25-55

 

25-55

 

114

55-85

35-65

 

35-65

 

149

50-80

 

50-80

 

060N

20-50

20-50

 

20-50

 

090N

30-60

30-60

 

30-60

Manifold Pressure (in. wg)

120N

40-70

 

40-70

 

 

 

 

 

 

Natural Gas — Std

 

3.5

3.5

 

3.5

3.5

Liquid Propane — Alt††

 

3.5

3.5

 

3.5

3.5

Maximum Static Pressure (in. wg)

 

1.0

1.0

 

1.0

1.0

Field Gas Connection Size (in.)

 

1/2

1/2

 

1/2

1/2

HIGH-PRESSURE SWITCH (psig)

 

 

450 ± 50

 

 

Standard Compressor Internal Relief

 

 

 

 

Cutout

 

 

428

 

 

Reset (Auto.)

 

 

320

 

 

LOSS-OF-CHARGE SWITCH/LOW-PRESSURE

 

 

 

 

 

 

SWITCH (Liquid LIne) (psig)

 

 

7 ± 3

 

 

Cutout

 

 

 

 

Reset (Auto.)

 

 

22 ± 5

 

 

FREEZE PROTECTION THERMOSTAT

 

 

30 ± 5

 

 

Opens (F)

 

 

 

 

Closes (F)

 

 

45 ± 5

 

 

OUTDOOR-AIR INLET SCREENS

 

 

Cleanable

 

Quantity...Size (in.)

 

 

1...20 x 24 x 1

 

RETURN-AIR FILTERS

 

 

Throwaway

4...16 x 16 x 2

Quantity...Size (in.)

 

 

2...16 x 25 x 2

 

LEGEND

Bhp — Brake Horsepower

*Single phase/three phase. †Indicates automatic reset.

**60,000 and 72,000 Btuh heat input units have 2 burners. 90,000 and 120,000 Btuh heat input units have 3 burners. 115,000 Btuh heat input units and 150,000 Btuh Heat input units have 3 burners.

††An LP kit is available as an accessory. If an LP kit is used with low NOx units, one low NOx baffle must be removed and the units will no longer be classified as low NOx units.

California compliant three-phase models.

***California SCAQMD compliant low NOx models have combustion products that are controlled to 40 nanograms per joule or less.

7

Image 7
Contents Provide Unit Support ContentsSafety Considerations InstallationIII. Determine Location of Drain Line and External Trap II. Field Fabricate DuctworkCRBTMPWR003A01 Roof Curb Unit Size Accessory CRRFCURB001A01CRBTMPWR001A01 CRBTMPWR002A01 Positioning Install Flue Hood VI. Install GAS Piping IV. RIG and Place Unit060 Unit Operating Weight581B 036 048Physical Data 581B036-072 OUTDOOR-AIR Inlet Screens LOSS-OF-CHARGE SWITCH/LOW-PRESSUREFurnace Section Freeze Protection ThermostatBase Unit Dimensions 581B036-072 Steel Pipe Spacing of Supports Nominal Diameter Dimension Field Power SupplyField Control Wiring Heat Anticipator SettingsLow-Voltage Connections With or Without Economizer Power Wiring ConnectionsRLA LRA FLA MCA Mocp Power Exhaust MCA MocpFAN Motor Disconnect SIZE†FAN Motor Supply SIZE†LPS VIII. Adjust FACTORY-INSTALLED OptionsDisconnect Switch Perfect Humidity Dehumidification SystemManual Outdoor-Air Damper Damper Panel with Manual Outdoor-Air Damper InstalledOptional Manual Outdoor-Air Damper With Hood Attached EconoMi$er IV Standard Sensors Indoor Coil Access Panel RelocationBarometric Flow Capacity EconoMi$er IV Control Modes Supply Air Sensor Temperature/Resistance ValuesEconoMi$er IV Sensor Usage Return Air Temperature or Enthalpy Sensor Mounting Location Enthalpy Changeover Set Points Page 581B Fan Rpm at Motor Pulley Setting With Standard Motor IX. Adjust EVAPORATOR-FAN Speed581B Fan Rpm at Motor Pulley Setting With High-Static Motor AMP Draw Phase Continuous BHPUnit Maximum Unit Voltage 581BOutdoor Sound Power Total Unit Accessory/FIOP EconoMi$er IV Static Pressure* in. wgEvaporator-Fan Motor Data High-Static Motors 1292 1294 1175 1346 1275 1400 1147 9721265 1320 1310 1371 1419 1500 1175 1086760 666 257 778 367 871 471 952 572670 701 306 810 426 901 540 981 6511967 16491803 1470 17841049 731 967 5631008 643 805807 358 894 466 971 Rpm Bhp Watts 900 553 134782 316 870 417 948 1000 582 163740 382 643 234 762675 277 707 326919 561 800 350 904 438 999 535839 412 938 505 1030 605 879 483 974 580829 800 350 904 438 999 535 1087 640753 839 412 938 505 1030 605 1115 714General FAN Performance Notes START-UP Unit Preparation VI. Internal WiringVII. Refrigerant Service Ports PRE-START-UPXI. Main Burners CoolingXII. Heating XV. Operating Sequence XIII. Safety ReliefThermostat Input Economizer Function 581B Unit Operation Perfect Humidity Normal Design Cooling OperationVII. LOSS-OF-CHARGE Switch Service CleaningIV. ECONOMI$ER IV Adjustment VI. HIGH-PRESSURE SwitchUnit 581B To Use Cooling Charging Chart, Standard UnitLow Charge Cooling Perfect Humidity System ChargingCooling Charging Chart, Standard 581B036 Condenser FAN Must be Operating XI. COMBUSTION-AIR Blower XII. Limit SwitchXV. Replacement Parts Flue GAS PassagewaysMedium High Heat Units LOW Heat UnitsComp CAPOLR CLOLED OFF Troubleshooting Unit TroubleshootingLED Error Code Service Analysis Symptom Cause RemedyProblem Cause Remedy Heating Service AnalysisProblem Cause Remedy Cooling Service AnalysisII. ECONOMI$ER IV Troubleshooting Demand Control Enthalpy EconoMi$er IV Troubleshooting CompletionEconoMi$er IV Input/Output Logic Inputs OutputsIndex Page III. START-UP Electrical START-UP ChecklistTemperatures Preliminary Information