Bryant 581B Furnace Section, Loss-Of-Charge Switch/Low-Pressure, Freeze Protection Thermostat

Page 7

Table 1 — Physical Data — 581B036-072 (cont)

UNIT SIZE 581B

 

036

048

 

060

072

FURNACE SECTION

 

 

 

 

 

 

Rollout Switch Cutout Temp (F)†

 

195

195

 

195

195

Burner Orifice Diameter (in. ...drill size)**

 

 

 

 

 

 

Natural Gas — Std

071/072

.113...33

.113...33

 

.113...33

.113...33

 

114/115

.113...33

.113...33

 

.113...33

.113...33

 

149/150

.129...30

 

.129...30

.129...30

 

060N

.102...38

.102...38

 

.102...38

 

090N

.102...38

.102...38

 

.102...38

 

120N

.116...32

 

.116...32

Liquid Propane — Alt††

071/072

.089...43

.089...43

 

.089...43

.089...43

 

114/115

.089...43

.089...43

 

.089...43

.089...43

 

149/150

.102...38

 

.102...38

.102...38

 

060N

.082...45

.082...45

 

.082...45

 

090N

.082...45

.082...45

 

.082...45

Thermostat Heat Anticipator Setting (amps)

120N

.094...42

 

.094...42

 

 

 

 

 

 

208/230/460 v

 

 

 

 

 

 

First Stage

 

.14

.14

 

.14

.14

Second Stage

 

.14

.14

 

.14

.14

Gas Input (Btuh)

 

 

 

 

 

 

First Stage/Second Stage (3-phase units)

072

50,000/ 72,000

50,000/ 72,000

 

50,000/ 72,000

50,000/ 72,000

 

115

82,000/115,000

82,000/115,000

 

82,000/115,000

82,000/115,000

 

150

120,000/150,000

 

120,000/150,000

120,000/150,000

 

071II

—/ 72,000

—/ 72,000

 

—/ 72,000

 

114II

—/115,000

—/115,000

 

—/115,000

 

149II

—/150,000

 

—/150,000

 

060N***

—/ 60,000

—/ 60,000

 

—/ 60,000

 

090N***

—/ 90,000

—/ 90,000

 

—/ 90,000

 

120N***

—/120,000

 

—/120,000

Efficiency (Steady State) (%)

072

82.8

82.8

 

82.8

82

 

115

80

81

 

81

81

 

150

80.4

 

80.4

80

 

071

82

82

 

82

 

114

80

81

 

81

 

149

80

 

80

 

060N

80.2

80.2

 

80.2

 

090N

81

81

 

81

 

120N

80.7

 

80.7

Temperature Rise Range

072

25-55

25-55

 

25-55

25-55

 

115

55-85

35-65

 

35-65

35-65

 

150

50-80

 

50-80

50-80

 

071

25-55

25-55

 

25-55

 

114

55-85

35-65

 

35-65

 

149

50-80

 

50-80

 

060N

20-50

20-50

 

20-50

 

090N

30-60

30-60

 

30-60

Manifold Pressure (in. wg)

120N

40-70

 

40-70

 

 

 

 

 

 

Natural Gas — Std

 

3.5

3.5

 

3.5

3.5

Liquid Propane — Alt††

 

3.5

3.5

 

3.5

3.5

Maximum Static Pressure (in. wg)

 

1.0

1.0

 

1.0

1.0

Field Gas Connection Size (in.)

 

1/2

1/2

 

1/2

1/2

HIGH-PRESSURE SWITCH (psig)

 

 

450 ± 50

 

 

Standard Compressor Internal Relief

 

 

 

 

Cutout

 

 

428

 

 

Reset (Auto.)

 

 

320

 

 

LOSS-OF-CHARGE SWITCH/LOW-PRESSURE

 

 

 

 

 

 

SWITCH (Liquid LIne) (psig)

 

 

7 ± 3

 

 

Cutout

 

 

 

 

Reset (Auto.)

 

 

22 ± 5

 

 

FREEZE PROTECTION THERMOSTAT

 

 

30 ± 5

 

 

Opens (F)

 

 

 

 

Closes (F)

 

 

45 ± 5

 

 

OUTDOOR-AIR INLET SCREENS

 

 

Cleanable

 

Quantity...Size (in.)

 

 

1...20 x 24 x 1

 

RETURN-AIR FILTERS

 

 

Throwaway

4...16 x 16 x 2

Quantity...Size (in.)

 

 

2...16 x 25 x 2

 

LEGEND

Bhp — Brake Horsepower

*Single phase/three phase. †Indicates automatic reset.

**60,000 and 72,000 Btuh heat input units have 2 burners. 90,000 and 120,000 Btuh heat input units have 3 burners. 115,000 Btuh heat input units and 150,000 Btuh Heat input units have 3 burners.

††An LP kit is available as an accessory. If an LP kit is used with low NOx units, one low NOx baffle must be removed and the units will no longer be classified as low NOx units.

California compliant three-phase models.

***California SCAQMD compliant low NOx models have combustion products that are controlled to 40 nanograms per joule or less.

7

Image 7
Contents Provide Unit Support ContentsSafety Considerations InstallationIII. Determine Location of Drain Line and External Trap II. Field Fabricate DuctworkCRBTMPWR003A01 Roof Curb Unit Size Accessory CRRFCURB001A01CRBTMPWR001A01 CRBTMPWR002A01Positioning Install Flue HoodVI. Install GAS Piping IV. RIG and Place Unit060 Unit Operating Weight581B 036 048Physical Data 581B036-072 OUTDOOR-AIR Inlet Screens LOSS-OF-CHARGE SWITCH/LOW-PRESSUREFurnace Section Freeze Protection ThermostatBase Unit Dimensions 581B036-072 Steel Pipe Spacing of Supports Nominal Diameter Dimension Field Power SupplyField Control Wiring Heat Anticipator SettingsLow-Voltage Connections With or Without Economizer Power Wiring ConnectionsRLA LRA FLA MCA Mocp Power Exhaust MCA MocpFAN Motor Disconnect SIZE†FAN Motor Supply SIZE†LPS VIII. Adjust FACTORY-INSTALLED OptionsDisconnect Switch Perfect Humidity Dehumidification SystemManual Outdoor-Air Damper Damper Panel with Manual Outdoor-Air Damper InstalledOptional Manual Outdoor-Air Damper With Hood Attached EconoMi$er IV Standard Sensors Indoor Coil Access Panel RelocationBarometric Flow Capacity EconoMi$er IV Control Modes Supply Air Sensor Temperature/Resistance ValuesEconoMi$er IV Sensor Usage Return Air Temperature or Enthalpy Sensor Mounting Location Enthalpy Changeover Set Points Page 581B Fan Rpm at Motor Pulley Setting With Standard Motor IX. Adjust EVAPORATOR-FAN Speed581B Fan Rpm at Motor Pulley Setting With High-Static Motor AMP Draw Phase Continuous BHPUnit Maximum Unit Voltage 581BOutdoor Sound Power Total Unit Accessory/FIOP EconoMi$er IV Static Pressure* in. wgEvaporator-Fan Motor Data High-Static Motors 1292 1294 1175 1346 1275 1400 1147 9721265 1320 1310 1371 1419 1500 1175 1086760 666 257 778 367 871 471 952 572670 701 306 810 426 901 540 981 6511967 16491803 1470 17841049 731 967 5631008 643 805807 358 894 466 971 Rpm Bhp Watts 900 553 134782 316 870 417 948 1000 582 163740 382 643 234 762675 277 707 326919 561 800 350 904 438 999 535839 412 938 505 1030 605 879 483 974 580829 800 350 904 438 999 535 1087 640753 839 412 938 505 1030 605 1115 714General FAN Performance Notes START-UP Unit Preparation VI. Internal WiringVII. Refrigerant Service Ports PRE-START-UPXI. Main Burners CoolingXII. Heating XV. Operating Sequence XIII. Safety ReliefThermostat Input Economizer Function 581B Unit Operation Perfect Humidity Normal Design Cooling OperationVII. LOSS-OF-CHARGE Switch Service CleaningIV. ECONOMI$ER IV Adjustment VI. HIGH-PRESSURE SwitchUnit 581B To Use Cooling Charging Chart, Standard UnitLow Charge Cooling Perfect Humidity System ChargingCooling Charging Chart, Standard 581B036 Condenser FAN Must be Operating XI. COMBUSTION-AIR Blower XII. Limit SwitchXV. Replacement Parts Flue GAS PassagewaysMedium High Heat Units LOW Heat UnitsComp CAPOLR CLOLED OFF Troubleshooting Unit TroubleshootingLED Error Code Service Analysis Symptom Cause RemedyProblem Cause Remedy Heating Service AnalysisProblem Cause Remedy Cooling Service AnalysisII. ECONOMI$ER IV Troubleshooting Demand Control Enthalpy EconoMi$er IV Troubleshooting CompletionEconoMi$er IV Input/Output Logic Inputs OutputsIndex Page III. START-UP Electrical START-UP ChecklistTemperatures Preliminary Information
Related manuals
Manual 40 pages 47.12 Kb Manual 64 pages 44.36 Kb

581B specifications

The Bryant 581B is an innovative and highly efficient gas furnace that stands out in the HVAC market for its remarkable performance, reliability, and advanced features. Designed to provide optimal heating comfort, the Bryant 581B is perfect for homeowners seeking both quality and energy efficiency.

One of the main features of the Bryant 581B is its impressive Annual Fuel Utilization Efficiency (AFUE) rating. With an AFUE rating of up to 80%, this gas furnace maximizes energy usage, ensuring that a significant portion of the fuel is converted into heat for your home. This efficiency not only translates into lower energy bills but also reduces the carbon footprint, making it an environmentally friendly choice.

The furnace is equipped with a multi-speed blower motor that enhances comfort by providing consistent airflow throughout the home. This technology adjusts to different heating demands, ensuring that every room reaches the desired temperature without the discomfort of hot or cold spots. The quiet operation of the blower motor also adds to the overall comfort, creating a peaceful home environment.

Another notable characteristic of the Bryant 581B is its durable construction. It features a robust heat exchanger built from high-quality materials, designed to withstand the rigors of daily use. The compact design of the furnace allows it to fit seamlessly into various spaces, making it an ideal choice for both new installations and replacement projects.

The Bryant 581B also comes with advanced safety features, including a self-diagnostic control board that monitors the system's performance. This feature allows for easy troubleshooting and maintenance, prolonging the life of the furnace. Additionally, the furnace is equipped with an induced draft blower that enhances venting efficiency and safety by ensuring that combustion gases are safely expelled from the home.

For homeowners looking for enhanced control, the Bryant 581B is compatible with a range of smart thermostats, providing the ability to monitor and adjust heating settings remotely. This integration with smart technology ensures that homeowners can maintain their desired comfort levels while maximizing efficiency.

In conclusion, the Bryant 581B gas furnace is a top-tier option that combines efficiency, durability, and modern technology. With its high AFUE rating, multi-speed blower, and advanced safety features, it promises to deliver unparalleled comfort and peace of mind for years to come. Whether for a new build or an upgrade, the Bryant 581B is an investment that pays off in both comfort and savings.