Outback Power Systems FX 2024 T Torque Requirements, Connection Torque in Pound Measures

Page 15

TORQUE REQUIREMENTS

CONNECTION

TORQUE IN POUND MEASURES

 

 

AC and PV breakers

to 22 inch-lbs = 2.48 Nm

 

 

DC shunt

to 15 foot-lbs = 20.4 Nm

 

 

DC battery connections

to 10 foot-lbs = 13.6 Nm

 

 

FX’s DC Terminals

to 10 foot-lbs = 13.6 Nm

 

 

FX’s AC Terminals

to 30 inch-lbs = 3.38 Nm

 

 

Table 1 Torque Values for Installation

12

Image 15
Contents FX and VFX Series INVERTER/CHARGER Page Warranty Introduction Table of Contents FX Series Inverter/Charger Models Initial Inspection Important Safety InstructionsGenerate Explosive Gases During Normal Operation Personal PrecautionsSystem Protection DC Wiring OriginationAC Wiring Compartment Board AC Wiring OriginationAC and DC Grounding Requirements AC Conduit Plate Battery Terminal Covers Turbo FAN Cover FX-DCC DC Compartment CoverFX-DCA DC Conduit Adapter Mounting LOW Voltage Terminals Control Terminal Wiring Block JumperFollow these steps to wire the FX to your system Wire ConnectionsConnection Torque in Pound Measures Torque RequirementsChassis Ground AC Wiring Notes for the NON-MOBILE FXAC HOT OUT AC Neutral OUT/AC NeutralAC Neutral OUT/AC Neutral AC Wiring Notes for the Mobile FXInverter and ON/OFF LOW-VOLTAGE WiringAuxiliary Output AUX + / AUX RJ-45 jack connects Mate or HUB to FX using CAT5 cable RTS, MATE/HUB WiringSingle FX System Sample InstallationsSeries or SERIES/PARALLEL Dual FX Configuration Series/Parallel Using Two FXs Series/Parallel Using Four FXs Paralleled Dual FX System SERIES/PARALLEL Quad FX System Phase FX System Three-Phase System Generator Auto Start Mobile FX Information GENMate HUB Installation Check ListMaximum DC Input Current Appendix RatingsNominal AC Output Voltage of AN FX System Recommended FX DC Voltage RangeMaximum AC Input Current Maximum Current for Battery ChargerRated DC Input Current AC Input Operating Voltage RangeMaximum Continuous Output Power AC Input Frequency RangeMaximum AC Output Current Maximum Overcurrent Protection Ampacity Wire SizesMaintenance OutBack Power Systems Two Year Limited Warranty WarrantyProduct Registration Extended Warranty Application U.S. and Canada only