Grizzly G0651, G0652 owner manual Clean Up, Site Considerations, Floor Load, Placement Location

Page 22

Clean Up

The unpainted surfaces are coated with a waxy oil to prevent corrosion during shipment. Remove this protective coating with a solvent cleaner or degreaser, such as shown in Figure 9. For thor- ough cleaning, some parts must be removed.

For optimum performance, clean all moving parts or sliding contact surfaces. Avoid chlo- rine-based solvents, such as acetone or brake parts cleaner that may damage painted surfac- es. Always follow the manufacturer’s instructions when using any type of cleaning product.

Gasoline and petroleum products have low flash points and can explode or cause fire if used to clean machinery. DO NOT use these products to clean the machinery.

Many cleaning solvents are toxic if inhaled. Minimize your risk by only using these products in a well ventilated area.

G2544—Solvent Cleaner & Degreaser

A great product for removing the waxy shipping grease from your machine during clean up.

Site Considerations

Floor Load

Refer to the Machine Data Sheet for the weight and footprint specifications of your machine. Some residential floors may require additional reinforcement to support both the machine and operator.

Placement Location

Consider existing and anticipated needs, size of material to be processed through each machine, and space for auxiliary stands, work tables or other machinery when establishing a location for your new machine. See Figure 10 for the mini- mum working clearances.

,*

.&&$'

Figure 10. Minimum working clearances.

Children and visitors may be seriously injured if unsuper- vised around this machine. Lock entrances to the shop or disable start switch or power connection to prevent unsupervised use.

Figure 9. Cleaner/degreaser available from

Grizzly.

-20-

G0651/G0652 10" Extreme Series Table Saws

Image 22
Contents Extreme Series Table Saws Ss ,EAD from Leadbased PAINTS Table of Contents Contact Info IntroductionForeword Functional Overview#.% $!4 #ONSTRUCTION $%,$ %842%-%23%2%3 4!,% G0651/G0652 10 Extreme Series Table Saws Identification G0651 Identification !,7!93 53% !.3 !002/6%$$ 3!&%49 ,!33%33 7%. /0%2!4  !,7!93 53%3 %!2.2 02/4%#4/ %. /0%2!4.! -!#.%29 -!.9 -!#.%3 #!. %*%#4 7/2+0%#%3 4/7!2$ /0%2!4/2  53%3!!2/5.$%$ %84%.3/..#/2$ 2!4%$4&/2/4%-!#.%!-0%2!%2 53%3 2%#/--%.$%$- !##%33/2%3  !,7!93 ,/#+ -/,% !3%3 & 53%$ % %&/2% /0%2!4. -!#.%29#Safety Instructions for Table Saws Protecting Yourself From Kickback Preventing KickbackBelow are tips to avoid the most common causes of kickback Glossary of Terms Circuit Requirements Model G0651 OperationMinimum Cord Requirements Phase Converter PrecautionModel G0652 220/440V Operation Full Load Amp Draw440V Conversion Items Needed for Setup SetupSetup Safety UnpackingFence InventoryTable Saw Unit Fence RailExtension Table Outfeed TableHardware Recognition Chart Site Considerations Clean UpPlacement Location Floor LoadAssembly To assemble the extension table and outfeed tablesPage Page Saw Blade To install the bladeTo install the blade guard Blade Guard SplitterRiving Knife Table Insert To install the riving knifeTo install and adjust the table insert InsertOn/Off Switch Miter Gauge Fence Components Dust Collection To connect a dust collection hoseTest Run To test run the machineIncoming Power Wires Contactor Operation Safety Basic Controls OperationsCrosscut blade features Ripping blade featuresBlade Selection Laminate blade features Combination blade featuresDado Blades Non-Through Cuts Workpiece InspectionNon-Through Through Cuts Through CutsRipping Typical ripping operationCrosscutting Miter Cuts To make a crosscut using the miter gaugeTo perform a miter cut Blade Tilt/Bevel Cuts Using a Stacked or Wobble Dado BladeDado Cutting Using a Standard Saw Blade to Cut Dadoes Rabbet Cutting Cutting Rabbets with Dado BladeCuting Rabbets with Standard Blade Rabbet cutting with a standard bladeResawing Resaw Barrier Auxiliary FenceResawing Operations Components Needed for ResawingGZhVl ZcXZ 7VggZg $ -8dccZXidc H7583-Grizzly Tenoning Jig AccessoriesT20646-Zero Clearance Insert for G0651/ G0652 H9587-Table Saw FundamentalsG0638 10HP Cyclone Dust Collector G7581-Superbar G7582-Master PlateSchedule MaintenanceCleaning LubricationTroubleshooting ServiceMotor & Electrical Table Saw Operations Removing Flat Belt Replacing Flat BeltTools Needed Qty Installing New Belt Blade Tilt Stops Setting 90 Stop BoltSetting 45 Stop Bolt StepTo adjust the table tilt gear backlash Adjusting Tilt Indicator ArrowTable Tilt Handwheel Backlash Miter Slot to Blade Parallelism To adjust the blade parallel to the miter slotDigital Readout To set the digital readoutShim procedure diagram a Blade Alignment Adjusting FenceTo adjust the blade alignment by moving the table Square and HeightClamping Pressure and Parallelism Wrench 8mm Wiring Electrical Safety InstructionsG0651/G0652 Electrical Components G0651 motor junction boxSee Figure G0651 Wiring Diagram 220V, 1-PhHLI8= See Figure G0652 magnetic switch prewired to 220V, 3-phase G0652 Electrical ComponentsG0652 Wiring Diagram 220V, 3-Ph Motor DirectionG0652 Wiring Diagram 440V, 3-Ph 440 VACParts Motor and Arbor BreakdownMotor and Arbor Parts List DescriptionG0651 3HP, 220V, 1-PHASE Switch Cabinet Breakdown Cabinet Parts List DescriptionBlade Guard Breakdown Fence Assembly Breakdown Miter Gauge Breakdown Extension Table Breakdown Outfeed Table Breakdown Label Placement 22!.49 #!2$ 99.$5342!, .# 0//88 %,,.!- 7!  WARRANTY7!22!.499!AND.$$2%452RETURNS.3 #ALL 4ODAYD&ORO! &2%%