Grizzly G0613, G0614 owner manual Service, Troubleshooting

Page 32

SECTION 7: SERVICE

Review the troubleshooting and procedures in this section to fix your machine if a problem develops. If you need replacement parts or you are unsure of your repair skills, then feel free to call our Technical Support at (570) 546-9663.

Troubleshooting

Motor & Electrical

SYMPTOM

 

POSSIBLE CAUSE

 

CORRECTIVE ACTION

Machine does not start or a

1.

E-Stop button pressed.

1.

Twist E-Stop button until it pops out.

breaker trips.

2.

Plug/receptacle is at fault or wired

2.

Test for good contacts; correct the wiring.

 

 

incorrectly.

 

 

 

3.

Start capacitor is at fault (G0613).

3.

Test/replace capacitor if faulty.

 

4.

Wall fuse/circuit breaker is blown/

4.

Ensure correct size for machine load; replace weak

 

 

tripped.

 

breaker.

 

5.

Motor connection wired incorrectly.

5.

Correct motor wiring connections.

 

6.

Power supply is at fault/switched

6.

Ensure hot lines have correct voltage on all legs and

 

 

OFF.

 

main power supply is switched ON.

 

7.

Motor ON/OFF switch is at fault.

7.

Replace faulty ON/OFF switch.

 

8.

Wiring is open/has high resistance.

8.

Check for broken wires or disconnected/corroded

 

 

 

 

connections, and repair/replace as necessary.

 

9.

Motor is at fault.

9.

Test/repair/replace.

 

 

 

 

 

Machine stalls or is under-

1.

Wrong blade for the workpiece

1.

Use blade with correct properties for your type of cut-

powered.

 

material.

 

ting.

 

2.

Wrong workpiece material.

2.

Use metal with correct properties for your type of cut-

 

 

 

 

ting.

 

3.

Feed rate/cutting speed too fast for

3.

Decrease feed rate/cutting speed.

 

 

task.

 

 

 

4.

Blade is slipping on wheels.

4.

Adjust blade guides and tension.

 

5.

Incorrect power supply voltage.

5.

Ensure hot lines have correct voltage on all legs.

 

6.

Motor bearings are at fault.

6.

Test by rotating shaft; rotational grinding/loose shaft

 

 

 

 

requires bearing replacement.

 

7.

Plug/receptacle is at fault.

7.

Test for good contacts; correct the wiring.

 

8.

Motor connection is wired incor-

8.

Correct motor wiring connections.

 

 

rectly.

 

 

 

9.

Motor has overheated.

9.

Clean off motor, let cool, and reduce workload.

 

10. Motor is at fault.

10. Test/repair/replace.

 

 

 

 

 

Machine has vibration or

1.

Motor fan is rubbing on fan cover.

1.

Replace dented fan cover; replace loose/damaged

noisy operation.

 

 

 

fan.

 

2.

Blade is at fault.

2.

Replace/resharpen blade.

 

3.

Wormgear is at fault.

3.

Rebuild gearbox for bad gear(s)/bearing(s).

 

4.

Wrong blade for material.

4.

Change blade.

 

5.

Speed is set too slow.

5.

Adjust speed as required.

 

 

 

 

 

-30-

G0613/14 Swivel Mast Metal Cutting Bandsaw

Image 32
Contents Model G0613/G0614 Swivel Mast Metal Cutting Bandsaw Page Table of Contents Contact Info IntroductionForeword Machine Data Sheet 41⁄4 Model G0614 Swivel Mast METAL-CUTTING Bandsaw ⁄ 4 x 2 3⁄ Identification Control Panel Safety Safety Instructions for MachineryAlways Lock Mobile Bases if Used Before Operating Machinery Additional Safety Instructions for Bandsaws 110/220V Single Phase G0613 Circuit Requirements220V 3-Phase G0614 GroundingSetup Safety Items Needed for SetupUnpacking Description QtyInventory Shipping Crate Figure QtyClean Up Site ConsiderationsTo assemble the cabinet Cabinet AssemblyMounting to Shop Floor Cutting Fluid System To use the cutting fluid systemFactory adjustments that should be verified Recommended Test RunTo set the angle of cut Operation Safety Cutting AngleOperations To use the vise To install the workstopWorkstopVise Page Blade Selection Blade SpeedSplash Tray Using Blade GuidesTo adjust the upper blade guide Setting Feed Rate To set the feed rateCutting Fluid Tips Operation TipsAccessories G7897-Machining FluidH1300 H1298 G7984 H2347 H0736 H1302-Standard EarmuffsH1302 H4979 H4977 Maintenance CleaningSchedule LubricationService TroubleshootingBandsaw Operations Disconnect the Bandsaw from Power Blade ChangeBlade Tension Blade tension stop boltLower blade guide limit switch Blade Guides G0613Page Upper blade guide adjustments Limit Switch Bracket Blade Guides G0614Auto stop To adjust the blade-to-vise squareness Swivel StopsTo adjust the feed stop bolt Feed StopFeed Auto Stop To set the auto stopBlade-to-Vise Squareness Checking blade squareness to vise Cap ScrewG0613 control panel wiring Electrical Components G0613Electrical Components G0614 G0614 on buttonG0614 contactors G0614 pump motor data/connection G0614 main junction G0613 220V Single-Phase Wiring Diagram G0614 220V Three-Phase Wiring Diagram Parts Headstock and Bow Breakdown G0613Parts List G0613 DescriptionHeadstock and Bow Breakdown G0614 Parts List G0614 Base Breakdown G0613 Vise JAW Adjustable ROD Base Breakdown G0614 Lever Electrical Box Breakdown G0613 Parts List G0613 Electrical Box Breakdown G0614 Electrical Mounting Plate Cabinet and Gearbox Breakdown G0613 & G01614 Front Panel Labels and Placement 401 402 404 411 405 406 410 409 408Warranty and Returns Page Page