Grizzly G0503 instruction manual Grounding, Phase Converter, Extension Cords, Connection Type

Page 15

Connection Type

Because of the high amperage draw from this machine, we recommend that you hardwire it directly to your circuit breaker and install a locking shut-off lever (see Figure 4) near the machine as a way to quickly disconnect the power and prevent accidental starting. We DO NOT recom- mend using an extension cord with this machine.

Figure 4. A power disconnect is preferable to

high current plugs and receptacles.

Your Shop Circuit Capacity

Always check to see if the wires in your circuit are capable of handling the amperage draw from your machine, as well as any other machines that could be operating on the same circuit. If you are unsure, consult a qualified electrician.

Grounding

In the event of an electrical short, grounding reduces the risk of electric shock by providing a path of least resistance to disperse electric cur- rent. This machine must be equipped with an electric cord that has an equipment grounding conductor. This conductor must be grounded in accordance with all local codes and ordinances.

Improper connections of the electrical-grounding conductor increases the risk of electric shock. Check with a qualified electrician or one of our service personnel if you do not understand the grounding instructions, or if you doubt the machine is properly grounded.

Electrocution or fire could result if this machine is not grounded correctly or if your electrical con- figuration does not com- ply with local and state codes. Ensure compliance by checking with a quali- fied electrician!

Phase Converter

When using a phase converter, the power from the manufactured power leg (sometimes called the wild wire) can fluxuate. Connect the manu- factured power leg to the S terminal to prevent damage to the transformer. The wire from the S terminal can handle some fluxuation because it goes directly to the motor. The power going to the R and T terminals goes to the transformer and must be consistent to prevent damage.

Extension Cords

Because of the high amperage draw from this machine, we do not recommend the use of exten- sion cords. Instead, position your equipment near installed wiring to eliminate the need for exten- sion cords.

Model G0503 (Mfg. Since 12/08)

-13-

Image 15
Contents Horizontal Resaw Bandsaw Page Table of Contents Accessories Maintenance Manual Accuracy Contact Info IntroductionIdentification Main view of machine features and controlsPage Control Panel Machine Data Safety Instructions for Machinery SafetyMany Machines will Eject the Workpiecetowardtheoperator Roll up or button sleeves at the cuff Additional Safety Instructions for ResawsDepressurize for Maintenance Additional Safety Instructions for HydraulicsAmperage Draw 220V 3-Phase 440V 3-PhaseMinimum Wire Requirements Circuit RequirementsConnection Type Phase ConverterGrounding Extension CordsPiece Inventory SET UPAbout this Section UnpackingHardware Recognition Chart See For Set UpClean Up Items NeededRemoving Resaw From the Crate Pallet Site ConsiderationsMounting Conveyor Belt Mounting Resaw to FloorTo attach the hydraulic drive to the conveyor Attaching HydraulicsTo attach the handwheel handle Installing Blade CoverAttaching Handwheel Handle To attach the blade coverTo mount the return rollers Positioning Control PanelMounting To mount the control panelTo connect the resaw to a dust collector Connecting to Installing the BladePage Connecting to Power To connect the resaw to the power sourceShut off the main power at the power source circuit breaker Test Run Blade Tension To adjust the tension Disconnect the resaw from powerTo prepare the workpiece for a precision cut Operation SafetyOperations Stock PreparationBlade Height Conveyor ControlsTo operate the infeed conveyor Outfeed pressure roller Pressure RollersResawing Most common causes of blade breakage are Blade InformationAccessories G1955-OxiSolvBlade & Bit CleanerG7895-Citrus Degreaser H4876 Lenox BladesH4874 H4875H4978 T20446 H4979 P0503A17-440V Conversion KitBelts MaintenanceCleaning MiscellaneousGreasing G0503 Grease SCHEDULE/CHECK-OFF ChartCheck the hydraulic fluid level daily Hydraulic Fluid Hydraulic System Schedule Minor ServiceSupplies Needed Qty Hydraulic System Major ServiceWheel Scrapers To clean the tank screenService About ServiceTracking Page To align the guide blocks Adjusting Blade GuidesBlade Elevation Gauge Adjusting Support WheelTo adjust the support wheel To adjust the blade elevation gaugeTo check the main conveyor table alignment Adjusting Main Conveyor TablePage To set the conveyor tracking Tracking ConveyorTo replace the conveyor belts Replacing ConveyorBelt Tensioning Replacing V-Belts To adjust the V-belt tension Disconnect the resaw from power220V Power Rewiring toG0503 Control Panel Date Approximate Hours Of Use Maintenance Performed Maintenance Log101 Model G0503 Mfg. Since 12/08 302 426 Model G0503 Mfg. Since 12/08 Model G0503 Mfg. Since 12/08 Model G0503 Mfg. Since 12/08 815 901 904 905 906 903 908 910 907 FLT A01-1 A16 MOTOR/START MOTOR/STOP Description Lower Hinge Liner WAY Rear Roller ARM Bracket Symptom Possible Cause Corrective Action TroubleshootingService Log Warranty and Returns Warranty Card Grizzly INDUSTRIAL, inc Box Bellingham, WA Page Order Hours a DAY