SECTION 2: CIRCUIT REQUIREMENTS

220V 3-Phase

440V 3-Phase

 

 

 

Serious personal injury could occur if you connect your machine to the power source before you have completed the set up pro- cess. DO NOT connect the machine to the power source until instructed to do so.

Wiring

The Model G0503 is prewired for 220V 3-phase operation.

Amperage Draw

The Model G0503 has a 20 HP main motor and a 2 HP hydraulic pump motor that will draw the following amps at 220V 3-phase:

Main Motor

48

Amps

Hydraulic Pump Motor

6

Amps

Circuit Breaker Requirements

Install the machine on a dedicated circuit to reduce the possibility of overloading the circuit and tripping the circuit breaker. If the circuit breaker trips and the circuit is of the correct load capacity, have the circuit inspected by a qualified electrician. Never use a larger circuit breaker than stated below, or you will increase the risk of fire.

Circuit Breaker

60 Amp

Minimum Wire Requirements

 

For 220V 3-phase operation, use the following type of wire:

Wire

6 GA. Copper

We recommend running THWN/THHN grade insulated wire through rigid conduit and hardwir- ing into a locking power disconnect. Consult a qualified electrician for information on local and national electrical codes.

-12-

Serious personal injury could occur if you connect your machine to the power source before you have completed the setup pro- cess. DO NOT connect the machine to the power source until instructed to do so.

Wiring

The Model G0503 is prewired for 220V 3-phase operation. If 440 voltage is required, rewire the machine per the instructions on page 49, and fol- low the circuit requirements on this page.

Amperage Draw

The Model G0503 has a 20 HP main motor and a 2 HP hydraulic pump motor that will draw the following amps at 440V 3-phase:

Main Motor

24

Amps

Hydraulic Pump Motor

3

Amps

Circuit Breaker Requirements

Install the machine on a dedicated circuit to reduce the possibility of overloading the circuit and tripping the circuit breaker. If the circuit breaker trips and the circuit is of the correct load capacity, have the circuit inspected by a qualified electrician. Never use a larger circuit breaker than stated below, or you will increase the risk of fire.

Circuit Breaker.........................................30 Amp

Minimum Wire Requirements

For 440V 3-phase operation, use the following type of wire:

Wire

10 GA. Copper

We recommend running THWN/THHN grade insulated wire through rigid conduit and hardwir- ing into a locking power disconnect. Consult a licensed electrician for information on local and national electrical codes.

Model G0503 (Mfg. Since 12/08)

Image 14
Contents Horizontal Resaw Bandsaw Page Table of Contents Accessories Maintenance Introduction Manual Accuracy Contact InfoMain view of machine features and controls IdentificationPage Control Panel Machine Data Safety Safety Instructions for MachineryMany Machines will Eject the Workpiecetowardtheoperator Additional Safety Instructions for Resaws Roll up or button sleeves at the cuffAdditional Safety Instructions for Hydraulics Depressurize for MaintenanceCircuit Requirements 220V 3-Phase 440V 3-PhaseMinimum Wire Requirements Amperage DrawExtension Cords Phase ConverterGrounding Connection TypeUnpacking SET UPAbout this Section Piece InventoryHardware Recognition Chart Items Needed For Set UpClean Up SeeSite Considerations Removing Resaw From the Crate PalletMounting Resaw to Floor Mounting Conveyor BeltAttaching Hydraulics To attach the hydraulic drive to the conveyorTo attach the blade cover Installing Blade CoverAttaching Handwheel Handle To attach the handwheel handleTo mount the control panel Positioning Control PanelMounting To mount the return rollersConnecting to Installing the Blade To connect the resaw to a dust collectorPage Shut off the main power at the power source circuit breaker Connecting to PowerTo connect the resaw to the power source Test Run To adjust the tension Disconnect the resaw from power Blade TensionStock Preparation Operation SafetyOperations To prepare the workpiece for a precision cutTo operate the infeed conveyor Blade HeightConveyor Controls Pressure Rollers Outfeed pressure rollerResawing Blade Information Most common causes of blade breakage areG7895-Citrus Degreaser AccessoriesG1955-OxiSolvBlade & Bit Cleaner H4875 Lenox BladesH4874 H4876P0503A17-440V Conversion Kit H4978 T20446 H4979Miscellaneous MaintenanceCleaning BeltsG0503 Grease SCHEDULE/CHECK-OFF Chart GreasingHydraulic Fluid Hydraulic System Schedule Minor Service Check the hydraulic fluid level dailyHydraulic System Major Service Supplies Needed QtyTo clean the tank screen Wheel ScrapersTracking ServiceAbout Service Page Adjusting Blade Guides To align the guide blocksTo adjust the blade elevation gauge Adjusting Support WheelTo adjust the support wheel Blade Elevation GaugeAdjusting Main Conveyor Table To check the main conveyor table alignmentPage Tracking Conveyor To set the conveyor trackingReplacing Conveyor To replace the conveyor beltsTo adjust the V-belt tension Disconnect the resaw from power Belt Tensioning Replacing V-BeltsRewiring to 220V PowerG0503 Control Panel Maintenance Log Date Approximate Hours Of Use Maintenance Performed101 Model G0503 Mfg. Since 12/08 302 426 Model G0503 Mfg. Since 12/08 Model G0503 Mfg. Since 12/08 Model G0503 Mfg. Since 12/08 815 901 904 905 906 903 908 910 907 FLT A01-1 A16 MOTOR/START MOTOR/STOP Description Lower Hinge Liner WAY Rear Roller ARM Bracket Troubleshooting Symptom Possible Cause Corrective ActionService Log Warranty and Returns Warranty Card Grizzly INDUSTRIAL, inc Box Bellingham, WA Page Order Hours a DAY