Grizzly G0503 instruction manual Rewiring to, 220V Power

Page 51

Rewiring to 440V

Converting the Model G0503 to 440V operation consists of 1) wiring the voltage transformer, 2) rewiring the main motor and the hydraulic pump motor, and 3) replacing the over-load relays with the relays included in the Model G0503 440V Conversion Kit (item #P0503909) that is sold separately.

Electrocution or fire may occur if your con- version does not comply with local and state codes. Have your wiring conversion inspected by a qualified electrician before connecting your machine to power.

To convert the Model G0503 to 440V:

1.Disconnect the resaw from the power source!

2.Open the electrical box and locate the volt- age transformer shown in Figure 68.

6.Remove the wiring covers on the main and hydraulic pump motors.

7.Wire the main and hydraulic pump drive motors as shown on the diagrams on the inside of each motor wire cover. Note—

Figures 69 & 70 are provided for reference and are current at the time that this manual was written. However, always use the dia- gram on the wire cover that comes with your motor! The circled references on the dia- grams represent the labels on the wires.

L1 L2 L3

220V POWER

Figure 69. Main motor 440V wiring.

Voltage Transformer

L1 L2 L3

440V POWER

Siemens Motor

Only

U1, U2 Orange

V1, V2 Black

W1, W2 Red

Figure 68. Inside of electrical box.

3.Move the wire from the 220V terminal on the voltage transformer to the 440V or 480V ter- minal depending on your voltage.

4.Replace the main motor relay with the 440V relay and set the dial to “30.”

5.Replace the hydraulic pump motor relay with the 440V relay and set the dial to “3.6.”

Model G0503 (Mfg. Since 12/08)

Figure 70. Elevation motor 440V wiring.

8.Replace any wire duct covers and motor caps you might have removed during this proce- dure, and close the electrical box door.

9.Have a qualified electrician inspect your work before test running the machine.

-49-

Image 51
Contents Horizontal Resaw Bandsaw Page Table of Contents Accessories Maintenance Manual Accuracy Contact Info IntroductionIdentification Main view of machine features and controlsPage Control Panel Machine Data Safety Instructions for Machinery SafetyMany Machines will Eject the Workpiecetowardtheoperator Roll up or button sleeves at the cuff Additional Safety Instructions for ResawsDepressurize for Maintenance Additional Safety Instructions for HydraulicsAmperage Draw 220V 3-Phase 440V 3-PhaseMinimum Wire Requirements Circuit RequirementsConnection Type Phase ConverterGrounding Extension CordsPiece Inventory SET UPAbout this Section UnpackingHardware Recognition Chart See For Set UpClean Up Items NeededRemoving Resaw From the Crate Pallet Site ConsiderationsMounting Conveyor Belt Mounting Resaw to FloorTo attach the hydraulic drive to the conveyor Attaching HydraulicsTo attach the handwheel handle Installing Blade CoverAttaching Handwheel Handle To attach the blade coverTo mount the return rollers Positioning Control PanelMounting To mount the control panelTo connect the resaw to a dust collector Connecting to Installing the BladePage Connecting to Power To connect the resaw to the power sourceShut off the main power at the power source circuit breaker Test Run Blade Tension To adjust the tension Disconnect the resaw from powerTo prepare the workpiece for a precision cut Operation SafetyOperations Stock PreparationBlade Height Conveyor ControlsTo operate the infeed conveyor Outfeed pressure roller Pressure RollersResawing Most common causes of blade breakage are Blade InformationAccessories G1955-OxiSolvBlade & Bit CleanerG7895-Citrus Degreaser H4876 Lenox BladesH4874 H4875H4978 T20446 H4979 P0503A17-440V Conversion KitBelts MaintenanceCleaning MiscellaneousGreasing G0503 Grease SCHEDULE/CHECK-OFF ChartCheck the hydraulic fluid level daily Hydraulic Fluid Hydraulic System Schedule Minor ServiceSupplies Needed Qty Hydraulic System Major ServiceWheel Scrapers To clean the tank screenService About ServiceTracking Page To align the guide blocks Adjusting Blade GuidesBlade Elevation Gauge Adjusting Support WheelTo adjust the support wheel To adjust the blade elevation gaugeTo check the main conveyor table alignment Adjusting Main Conveyor TablePage To set the conveyor tracking Tracking ConveyorTo replace the conveyor belts Replacing ConveyorBelt Tensioning Replacing V-Belts To adjust the V-belt tension Disconnect the resaw from power220V Power Rewiring toG0503 Control Panel Date Approximate Hours Of Use Maintenance Performed Maintenance Log101 Model G0503 Mfg. Since 12/08 302 426 Model G0503 Mfg. Since 12/08 Model G0503 Mfg. Since 12/08 Model G0503 Mfg. Since 12/08 815 901 904 905 906 903 908 910 907 FLT A01-1 A16 MOTOR/START MOTOR/STOP Description Lower Hinge Liner WAY Rear Roller ARM Bracket Symptom Possible Cause Corrective Action TroubleshootingService Log Warranty and Returns Warranty Card Grizzly INDUSTRIAL, inc Box Bellingham, WA Page Order Hours a DAY