Grizzly G0503 instruction manual Connecting to Power, To connect the resaw to the power source

Page 26

Connecting to

Power

Because of the high amperage draw from this machine, we recommend that you hardwire it directly to your circuit breaker and install a lock- ing power disconnect lever near the machine. See page 12 for wiring recommendations.

If you have performed all of the previous set up instructions, you are ready to connect the resaw to the power source.

Tools Needed

Qty

Phillips Head Screwdriver

1

Hardware Needed

Qty

Conduit (Not Included)

Varies

Power Wires (Not Included)

Varies

To connect the resaw to the power source:

1.Read through Section 2: Circuit Requirements on page 12 to double-check that your setup follows the safety and circuit requirements.

Note—When using a phase converter, the power from the manufactured power leg (sometimes called the wild wire) can fluxuate. Connect the manufactured power leg to the S terminal to pre- vent damage to the transformer. The wire from the S terminal can handle some fluxuation because it goes directly to the motor. The power going to the R and T terminals goes to the transformer and must be consistent to prevent damage.

2.Connect the power wires to the main termi- nal shown in Figure 23.

Figure 23. Main terminal.

3.Close and latch the electrical panel on the machine.

4.Shut off the main power at the power source circuit breaker.

5.Connect the conduit to the shut off lever box and the bottom of the electrical panel.

6.Install the power wires to the disconnect switch.

-24-

Model G0503 (Mfg. Since 12/08)

Image 26
Contents Horizontal Resaw Bandsaw Page Table of Contents Accessories Maintenance Introduction Manual Accuracy Contact InfoMain view of machine features and controls IdentificationPage Control Panel Machine Data Safety Safety Instructions for MachineryMany Machines will Eject the Workpiecetowardtheoperator Additional Safety Instructions for Resaws Roll up or button sleeves at the cuffAdditional Safety Instructions for Hydraulics Depressurize for MaintenanceCircuit Requirements 220V 3-Phase 440V 3-PhaseMinimum Wire Requirements Amperage DrawExtension Cords Phase ConverterGrounding Connection TypeUnpacking SET UPAbout this Section Piece InventoryHardware Recognition Chart Items Needed For Set UpClean Up SeeSite Considerations Removing Resaw From the Crate PalletMounting Resaw to Floor Mounting Conveyor BeltAttaching Hydraulics To attach the hydraulic drive to the conveyorTo attach the blade cover Installing Blade CoverAttaching Handwheel Handle To attach the handwheel handleTo mount the control panel Positioning Control PanelMounting To mount the return rollersConnecting to Installing the Blade To connect the resaw to a dust collectorPage Shut off the main power at the power source circuit breaker Connecting to PowerTo connect the resaw to the power source Test Run To adjust the tension Disconnect the resaw from power Blade TensionStock Preparation Operation SafetyOperations To prepare the workpiece for a precision cutTo operate the infeed conveyor Blade HeightConveyor Controls Pressure Rollers Outfeed pressure rollerResawing Blade Information Most common causes of blade breakage areG7895-Citrus Degreaser AccessoriesG1955-OxiSolvBlade & Bit Cleaner H4875 Lenox BladesH4874 H4876P0503A17-440V Conversion Kit H4978 T20446 H4979Miscellaneous MaintenanceCleaning BeltsG0503 Grease SCHEDULE/CHECK-OFF Chart GreasingHydraulic Fluid Hydraulic System Schedule Minor Service Check the hydraulic fluid level dailyHydraulic System Major Service Supplies Needed QtyTo clean the tank screen Wheel ScrapersTracking ServiceAbout Service Page Adjusting Blade Guides To align the guide blocksTo adjust the blade elevation gauge Adjusting Support WheelTo adjust the support wheel Blade Elevation GaugeAdjusting Main Conveyor Table To check the main conveyor table alignmentPage Tracking Conveyor To set the conveyor trackingReplacing Conveyor To replace the conveyor beltsTo adjust the V-belt tension Disconnect the resaw from power Belt Tensioning Replacing V-BeltsRewiring to 220V PowerG0503 Control Panel Maintenance Log Date Approximate Hours Of Use Maintenance Performed101 Model G0503 Mfg. Since 12/08 302 426 Model G0503 Mfg. Since 12/08 Model G0503 Mfg. Since 12/08 Model G0503 Mfg. Since 12/08 815 901 904 905 906 903 908 910 907 FLT A01-1 A16 MOTOR/START MOTOR/STOP Description Lower Hinge Liner WAY Rear Roller ARM Bracket Troubleshooting Symptom Possible Cause Corrective ActionService Log Warranty and Returns Warranty Card Grizzly INDUSTRIAL, inc Box Bellingham, WA Page Order Hours a DAY