SECTION 3: CIRCUIT REQUIREMENTS
Voltage & Amperage
Draw
The following list outlines the voltage required to operate the saws, as well as the amperage draw of their motors:
G0444 |
|
|
110V (prewired) | 18 | Amps |
220V | 9 | Amps |
G0444Z |
|
|
110V | 24 | Amps |
220V (prewired) | 12 | Amps |
Circuit Breaker
Use the following guidelines when choosing a cir- cuit breaker (circuit breakers rated any higher are not adequate to protect the circuit):
G0444 |
|
|
110V (prewired) | 20 Amp, 1 Pole | |
220V | 10 Amp, 2 Pole | |
G0444Z |
|
|
110V | 25 Amp, 1 Pole | |
220V (prewired) | 15 Amp, 2 Pole | |
|
|
|
|
|
|
|
|
|
|
|
|
Plug & Receptacle
The following list and figures outline the correct plug and receptacle to use:
G0444 |
110V (prewired)................................ NEMA |
220V................................................ NEMA |
*Not Included |
Figure 4. NEMA 5-15 plug and receptacle.
Figure 5. NEMA 6-15 plug and receptacle.
G0444/G0444Z 10" Table Saw |