Operating Instructions

Model SB3232

Operating The Tool

(Continued)

5.Always unload all fasteners before removing tool from service. Unloading is the reverse of loading, except always disconnect the air supply before unloading.

ADJUSTING THE FASTENER PENETRA- TION

1.Regulate the air pressure to 60 psi at the tool.

2.Connect the air

supply and test for penetration by driving fasteners into a sample piece of wood. If the fasteners do not achieve the desired penetration, adjust the air pressure to a higher setting until the desired penetration is achieved. Do not exceed 100 psi at the tool or durability of the tool will be reduced.

CLEARING A JAM FROM THE TOOL

1.Disconnect the air supply from

the tool.

2.Remove all fas- teners from the

magazine (see "Loading/ Unloading The

Tool"). Failure to do so will cause the fasteners to eject from the front of the tool when the nose assembly is removed.

3.Remove (3) cap nose of the tool plate, spacer and Element (WCE) fastener.

4.Reinstall nose assembly in reverse order in step #3.

5. Make sure the trig-

 

ger and Work

 

Contact Element

 

(WCE) move freely

movement

up and down with-

 

out sticking or binding.

 

Technical Support

Please call our Tool Hotline at 1-800- 543-6400 with any questions regarding the operation or repair of this tool or for additional copies of this manual.

Fastener And Replacement Parts

Use only

! WARNING genuine Campbell Hausfeld 18 gauge fasteners (or equiva- lent - see Fastener Interchange Information). Tool performance, safety and durability could be reduced if improper fasteners are used. When ordering replacement parts or fasten- ers, specify by part number.

Tool Repair

Only qualified personnel should repair the tool, and they should use genuine Campbell Hausfeld replacement parts and accessories, or parts and accessories which perform equivalently.

Assembly Procedure For Seals

When repairing a tool, the internal parts must be cleaned and lubricated. Parker O-lube or equivalent must be used on all o-rings. Each o-ring must be coated with O-lube before assembling. A small amount of oil must be used on all moving surfaces and pivots. After reassembling, a few drops of 30W non- detergent oil or equivalent, must be added through the air line before testing.

www.chpower.com

5

Image 5
Contents Description Table of ContentsGeneral Safety Information Model SB3232 Tool Components And SpecificationsAIR Inlet 1/4 NPT Magazine CapacityLubrication Operating The ToolRecommended Hookup Full Sequential Actuation Mechanism Recommended HookupChecking the Work Contact Element WCE LOADING/UNLOADING the ToolAssembly Procedure For Seals Fastener And Replacement PartsTechnical Support Tool RepairNails FastenersInterchange Information StaplesProblem Cause Solution Troubleshooting GuideWhat is not Covered Under this Warranty Limited WarrantyGénéralités sur la Sécurité Table des MatièresProposition 65 Californie Responsabilité DE L’UTILISATEURPièces Détachées et Modèle SB3232Spécifications de la Cloueuse Capacité DU ChargeurGénéralités sur la Sécurité Suite Branchement RecommandéUtilisation de l’outil Modèle SB3232Utilisation de l’outil Suite Branchement RecommandéMécanisme D’ACTIVATION À Séquence Complète Vérifier LE Mécanisme DEAttaches et Pièces de Rechange Support TechniqueAttaches et Réparation de la Cloueuse Méthode d’assemblage pour les joints d’étanchéitéClous AttachesInformation D’Interchangeabilité AgrafesGuide de Dépannage Problème Cause SolutionLA Présente Garantie NE Couvre PAS Garantie LimitéeInformaciones Generales de Seguridad ÍndiceDescripción Capacidad DEL Cargador Modelo SB3232Componentes y Especificaciones de la Clavadora Cómo usar la Herramienta Precaucion Ésto leConexión Recomendada LubricacionConexión Recomendada Precaucion ChequéeMecanismo DE Accionamiento Secuencial Total Como Chequear EL Elemento DE ContactoSujetadores y Piezas de Repuesto Servicio TécnicoPara reparar la herramienta Para colocarle los sellosClavos SujetadoresInformación de intercambio GrapasGuía de Diagnóstico de Averías Problema Causa SoluciónLO QUE no Esta Cubierto POR Esta Garantia Garantía Limitada