Graco 238512, 238515, 238511 Dispensing Fluid in Auto Mode, Viewing Totals

Page 12

Operation

Dispensing Fluid in Auto Mode

CAUTION

Before you begin a preset dispense cycle, make sure AUTO is displayed. If you do not see AUTO on the display, you are not in the Auto dispense mode, and fluid flow will not stop when the auto preset amount is dispensed.

1. Press the Auto/Reset button.

The display wakes up if it was asleep, and AUTO and the stored preset dispense amount are displayed. The factory default is 0.00.

NOTE: To change the stored preset dispense amount, see Auto Preset Amount on page 9.

2.You can dispense or change the displayed preset amount by doing one of the following:

DGo straight to step 3 to dispense the displayed preset amount.

OR

DTo change the displayed preset amount, you can set the display to zero by pressing the Auto/Reset button, then press the10 button to change the 10s digit, press the 1.0 button to change the 1s digit, and press the 0.1 button the change the first decimal digit. Then go to step 3.

3.Lock the trigger. See Locking and Unlocking the Trigger on page 11.

Fluid flows, and the displayed dispensed amount counts up from zero. When the preset amount is dispensed, the unit beeps, the trigger unlocks, fluid flow stops, the dispensed amount is displayed, and the meter switches to the Manual dispense mode.

If you want to stop fluid flow before the preset amount is dispensed, manually unlock the trigger. To continue the dispense, lock the trigger, and the dispensed amount resumes counting toward the preset amount.

If you want to continue dispensing after the trigger unlocks at the preset dispense amount, squeeze the trigger, and the dispensed amount resumes counting in the Manual dispense mode until you release the trig- ger.

NOTE: When the trigger unlocks, the automatic nozzle prevents the fluid in the extension from running out.

12 309377

Viewing Totals

This is the procedure for viewing the non-resettable and resettable totals. To change the resettable total, see Resettable Total on page 8.

1.If the display is blank, press the Manual/Reset or Auto/Reset button to wake it up.

2.Press the Total button to view the non-resettable total amount.

If the unit of measurement is gallons, quarts, or pints, the total is displayed in gallons, as shown below. If the unit of measurement is liters, the total is displayed in liters.

GAL

TOTAL

! CAUTION

To prevent overfills and spills

D Do not obstruct the trigger D Do not operate below 32_ F (0_ C) D Do not leave unattended D Read instruction manual

Maximum Working Pressure 7 MPa (70 bar, 1000 PSI)

06044A

3.Press the Total button again to view the resettable total amount.

If the unit of measurement is gallons, quarts, or pints, the resettable total is displayed in gallons, as shown below. If the unit of measurement is liters, the reset- table total is displayed in liters.

GAL

R-TOTAL

! CAUTION

To prevent overfills and spills

D Do not obstruct the trigger D Do not operate below 32_ F (0_ C) D Do not leave unattended D Read instruction manual

Maximum Working Pressure 7 MPa (70 bar, 1000 PSI)

06044A

Pressing the Total button repeatedly toggles between the non-resettable and resettable total.

4.Press the Manual/Reset or Auto/Reset button to return to the Manual or Auto dispensing mode.

Image 12
Contents Instructions -- Parts List Important Safety instructionsModel 238511 shown Table of Contents SymbolsFire and Explosion Hazard Installation Typical InstallationsMounting Bracket Mounting bracketPressure Relief Procedure Installation ProcedurePre-Installation Procedure Steps 2 through 6 are the Flushing ProcedureGrounding 309377 Model shown has Bend rigid ExtensionSetup Manual / Reset and Auto / ResetTerms Keypad ButtonsResettable Total Selecting Dispensing OptionsUnits of Measurement Auto Preset Amount Calibration FactorCalibration Number Fluid Quarts LitersShut-Off Default Amount This menu, you can change the shut-off default amountDispensing Fluid in Manual Mode OperationLocking and Unlocking the Trigger Checking Segments in the DisplayDispensing Fluid in Auto Mode Viewing TotalsTroubleshooting Problem Cause SolutionBattery on Replacing the Filter onInstallation Procedure See in Installation ProceRings. See Servicing the Valve Automatic Nozzle onError Code Cause Solution Shut-off Default Amount sectionSee the Auto Preset Amount ErrService Replacing the BatteryReplacing the Filter Servicing the Valve Replacing the Automatic NozzleParts List Description QtyIncludes 16a to 16e, 25, Meter housing Parts DrawingTechnical Data Dimensional Drawing Graco Standard Warranty Graco InformationToll Free 612--623--6928 612--378--3590 Fax