Troubleshooting
Problem | Cause | Solution | |
|
|
| |
Meter leaks from: |
|
| |
Cover/Control | Poor swivel (3)/hose connection. | Apply PTFE tape (leave minimum 2 | |
|
| engaged threads uncovered for | |
|
| electrical continuity) or sealant to | |
|
| threads of hose and tighten the | |
|
| connection. See step 9 in | |
|
| Installation Procedure. | |
| Poor swivel (3)/meter housing | Torque the fitting to | |
| connection. |
| |
| Damaged valve stem (16) assembly. | Replace or clean valve stem and | |
|
|
| |
| Poor seal at meter housing plate. | Contact your Graco distributor for | |
| NOTE: Place a straight edge along | repairs or replacement. | |
|
| ||
| meter housing plate. If flat, plate and |
| |
| seal are ok. If plate is not flat, meter |
| |
| is damaged. |
| |
|
|
| |
Meter leaks from: |
|
| |
Automatic | Automatic nozzle (5b, 6b, or 7b) has | Replace the nozzle. See Replacing | |
nozzle | |||
a damaged seal. | the Automatic Nozzle on page 17. | ||
NOTE: It is important to dis- | |||
Valve (16) has damaged or | Replace or clean valve stem and | ||
tinguish between the two | |||
obstructed seals. |
| ||
causes of this problem. A | |||
| page 17. | ||
new nozzle will not correct a |
| ||
fluid leak caused by a faulty |
|
| |
valve. |
|
| |
|
|
| |
Meter leaks from: |
|
| |
Swivel | Poor swivel (3)/hose connection | Apply PTFE tape (leave minimum 2 | |
| |||
|
| engaged threads uncovered for elec- | |
|
| trical continuity) or sealant to threads | |
|
| of hose and tighten the connection. | |
|
| See step 9 in Installation Proce- | |
|
| dure. | |
| Poor swivel (3)/meter housing | Torque the fitting to | |
| connection. |
| |
|
|
| |
Unit does not stop dispensing | Auto amount was not entered. | Enter a preset dispense amount in | |
when assumed auto amount |
| the Auto dispense mode. AUTO | |
is dispensed. |
| must be displayed below the amount. | |
| Trigger is obstructed, or unit has | Never set the unit down resting on its | |
| been set down resting on its trigger. | trigger. | |
|
|
|
14 309377