Troubleshooting
Error Codes
Error codes are listed below. Even in an error condi- tion, the unit keeps track of the amount dispensed. With any error code displayed, as shown at right, you can
DPress the Manual/Reset button.
Error code is cleared, unit switches into Manual mode, and dispensed amount is displayed.
DPress the Auto/Reset button.
Error code is cleared, unit switches into Auto mode, and the preset amount is displayed.
! CAUTION
To prevent overfills and spills
D Do not obstruct the trigger D Do not operate below 32_ F (0_ C) D Do not leave unattended D Read instruction manual
Maximum Working Pressure 7 MPa (70 bar, 1000 PSI)
06044A
Error Code | Cause | Solution |
|
|
|
Err 1 | Flow rate is higher than 5 gpm. | Adjust the flow rate so it is not higher |
| or | than 5 gpm. |
| Air was pumped through the line. | Purge air from the line. |
|
|
|
Err 2 | Switch Error: Error occurred with | Ensure that your flow rate is not |
| higher than 5 gpm. For further assis- | |
| or | tance, contact your Graco distributor. |
|
| |
| Unit was dropped or unit encoun- | Press the Manual/Reset button at |
| tered excessive vibration during | |
| shipping. |
|
|
|
|
Err 4 | Flow has continued after it should | Check if the unit is resting on the |
| have shut off. | trigger or if an obstruction is pressing |
|
| the trigger. The unit checks for flow |
|
| every two seconds, and it beeps and |
|
| repeats the error code until the |
|
| trigger is released and the error code |
|
| cleared. |
|
|
|
Err 5 | The unit has dispensed the | Press the Manual/Reset button, and |
| default amount and has stopped | dispense again. To change the |
| fluid flow. | |
|
|
|
|
| on page 10. |
|
|
|
Err 6 | A preset dispense amount of zero | Enter an amount that is not zero. |
| was entered for the dispense or is | See the Auto Preset Amount |
| stored as the default, and a Preset | section on page 9. |
| dispense was attempted. |
|
|
|
|
309377 15