Graco 238511, 238512, 238515 Selecting Dispensing Options, Resettable Total, Units of Measurement

Page 8

Setup

Selecting Dispensing Options

This is the procedure for setting or changing the resettable total, units of measurement, calibration factor, auto preset amount, and shut-off default amount:

1.If the display is asleep, wake it up by pressing the Manual/Reset or Auto/Reset button.

2.To enter the dispensing options menus from any mode, press and hold the Manual/Reset and Auto/Reset buttons simultaneously for four seconds.

The first menu is the Resettable Total menu, which is described in the first subsection below. You can advance through the menus by pressing the Auto/Reset button. You will know which menu you are in, because a menu indicator will be blinking in the display. The value that is displayed when you leave each menu and advance to the next is the value that gets stored.

Resettable Total

In this menu, you can reset the resettable total to zero or leave it unchanged. The resettable total accumu- lates until the next time it is manually reset.

1.If you have not already entered the dispensing options menus, do steps 1 and 2 in Selecting Dispensing Options above.

2.With R--TOTALblinking and the current resettable total displayed, as shown below, do ONE of the following two options:

DPress the Manual/Reset button.

The resettable total is set to zero, and 0 GAL or 0 LITERS is displayed.

You can press the Manual/Reset button again to toggle between zero and the previously displayed resettable total. To lock in the displayed value and advance to the Units of Measurement menu, press the Auto/Reset button.

OR

DPress the Auto/Reset button.

The currently displayed value is stored, and the display advances to the Units of Measurement menu.

GAL

R-TOTAL

! CAUTION

To prevent overfills and spills

D Do not obstruct the trigger D Do not operate below 32_ F (0_ C) D Do not leave unattended D Read instruction manual

Maximum Working Pressure 7 MPa (70 bar, 1000 PSI)

Units of Measurement

In this menu, you can set the units of measurement to quarts, gallons, pints, or liters.

1.If you have not already entered the dispensing options menus, do steps 1 and 2 in Selecting Dispensing Options above.

2.Press the Auto/Reset button repeatedly until QTS, GAL, LITERS, or PTS blinks to indicate that you are in the Units-of Measurement menu.

3.With QTS, GAL, LITERS, or PTS blinking, as shown below, do ONE of the following two options:

DPress the Manual/Reset button.

Each time you press the Manual/Reset button, the display scrolls to the next unit of measurement. To lock in the new unit of measurement and advance to the Calibration Factor menu, press the Auto/Reset button.

OR

DPress the Auto/Reset button.

The displayed unit of measurement is retained, and the display advances to the Calibration Factor menu.

GAL

! CAUTION

To prevent overfills and spills

D Do not obstruct the trigger D Do not operate below 32_ F (0_ C) D Do not leave unattended D Read instruction manual

Maximum Working Pressure 7 MPa (70 bar, 1000 PSI)

06044A

06044A

8 309377

Image 8
Contents Model 238511 shown Instructions -- Parts ListImportant Safety instructions Table of Contents SymbolsFire and Explosion Hazard Installation Typical InstallationsMounting Bracket Mounting bracketPressure Relief Procedure Installation ProcedurePre-Installation Procedure Steps 2 through 6 are the Flushing ProcedureGrounding 309377 Model shown has Bend rigid ExtensionSetup Manual / Reset and Auto / ResetTerms Keypad ButtonsUnits of Measurement Resettable TotalSelecting Dispensing Options Auto Preset Amount Calibration FactorCalibration Number Fluid Quarts LitersShut-Off Default Amount This menu, you can change the shut-off default amountDispensing Fluid in Manual Mode OperationLocking and Unlocking the Trigger Checking Segments in the DisplayDispensing Fluid in Auto Mode Viewing TotalsTroubleshooting Problem Cause SolutionBattery on Replacing the Filter onInstallation Procedure See in Installation ProceRings. See Servicing the Valve Automatic Nozzle onError Code Cause Solution Shut-off Default Amount sectionSee the Auto Preset Amount ErrReplacing the Filter ServiceReplacing the Battery Servicing the Valve Replacing the Automatic NozzleIncludes 16a to 16e, 25, Parts ListDescription Qty Meter housing Parts DrawingTechnical Data Dimensional Drawing Toll Free 612--623--6928 612--378--3590 Fax Graco Standard WarrantyGraco Information