Operation
Locking and Unlocking the Trigger
The trigger on this dispense valve has a locking mech- anism. In Auto mode, the unit stops dispensing when the entered amount has been dispensed. In Manual mode, the trigger does not automatically unlock; you must unlock it manually.
To lock the trigger, press on the part of the trigger that has the textured grip (see below) until you feel it click into the locked position.
To unlock the trigger, press on the smooth part of the trigger (see below) until you feel it click out of the locked position. When you release the trigger, fluid flow stops.
Press here | Press here |
|
to lock. | to unlock. | 06227A |
Checking Segments in the Display
When you press the Manual/Reset button or the Auto/Reset button when the display is awake and in the Manual or Auto dispense mode, the Segment Check is displayed briefly. This display allows you to check for burned out segments in the display. Press the Manual/Reset or Auto/Reset button repeatedly to get a good look at each segment in the display. The Segment Check should show all of the segments shown below.
|
| PTSQTS |
, | , , | GAL |
|
| LITERS |
| AUTO | CAL |
! CAUTION
To prevent overfills and spills
D Do not obstruct the trigger D Do not operate below 32_ F (0_ C) D Do not leave unattended D Read instruction manual
Maximum Working Pressure 7 MPa (70 bar, 1000 PSI)
06044A
Dispensing Fluid in Manual Mode
1. Press the Manual/Reset button.
If the display was asleep, it wakes up and displays the amount that was displayed before it fell asleep.
If the display was awake, and the meter is in the Manual dispense mode, the meter beeps, and the display clears to 0.00.
If the display was awake, and the unit is in the View- ing Totals mode or the Auto dispense mode, the meter switches to the Manual dispense mode.
2.When the display is awake, you can dispense from zero or from the displayed amount by doing one of the following:
D Press the Manual/Reset button again to clear the display to 0.00 if it is not already at 0.00. Then go to step 3.
OR
DGo straight to step 3 to dispense from the displayed amount.
3.Squeeze the trigger. You may lock it. See Lock- ing and Unlocking the Trigger at left.
Fluid flows, and the amount displayed counts up from zero or the previously dispensed amount.
4.Release/unlock the trigger when you have dis- pensed the desired amount of fluid.
Fluid flow stops, and the amount you have dispensed is displayed.
You may press the Manual/Reset button again to reset the displayed amount to zero.
NOTE: When the trigger is released, the automatic nozzle prevents the fluid in the extension from running out.
309377 11