Graco 238515, 238512 Setup, Terms, Keypad Buttons, 10, 1.0, Manual / Reset and Auto / Reset

Page 7

Setup

Terms

The following terms are shown on the display and/or used often in this instruction manual.

DR--TOTAL: resettable total

Displayed to show the cumulative amount that the dispense valve has dispensed in all modes. It can be reset to zero.

DTOTAL: non-resettable total

Displayed to show the cumulative amount that the dispense valve has dispensed in all modes for the history of the unit. It cannot be reset.

DMANUAL mode

Dispense mode in which the display counts up from zero to show the dispensed amount. In this mode, you may lock the trigger, but you must manually unlock it when the desired amount is dispensed. Memory setting also unlocks the trigger.

DAUTO mode

Dispense mode in which a preset, user-entered amount is dispensed. When the preset amount is dispensed, a beep sounds, the trigger unlocks to stop the unit from dispensing, and the amount dispensed is displayed. At this point, you may dispense more by pulling back the trigger, and the display resumes counting up in Manual mode.

DAsleep / Awake

Asleep is a battery-saving mode in which the dis- play goes blank after 45 seconds of inactivity during normal operation and 2 minutes when in the options menu. The display comes awake from sleep mode when you press the Manual/Reset or Auto/Reset button, but not when you squeeze the trigger to dispense fluid. The unit does keep track of the amount dispensed while the display is asleep.

NOTE: If the unit falls asleep after any dispense cycle, and you do wake it up by pressing the Auto/ Reset button, the previously dispensed amount is cleared, and the Auto mode dispense amount stored in memory is displayed. You will be at the beginning of an Auto mode dispense cycle.

If the unit falls asleep after any dispense cycle, and you do not wake it up by pressing the Manual/Re- set or Auto/Reset button, it will default to manual mode. When dispensing begins you will be at the beginning of a manual mode dispense cycle.

Keypad Buttons

The buttons on the keypad and their functions are as follows (see the figure below):

D10, 1.0, and 0.1

Used in Auto mode and during setup to enter dispense amounts.

DMANUAL / RESET and AUTO / RESET

Used individually to select Manual mode and Auto mode. Used together (pressed simultaneously) to access the setup menus.

For both of these buttons, the first push selects the mode, and the second push resets the display to zero.

DTOTAL

Used in any mode to see the resettable total and the non-resettable total.

NOTE: All buttons are disabled while fluid is being dispensed.

GAL

AUTO

06044A

309377 7

Image 7
Contents Important Safety instructions Instructions -- Parts ListModel 238511 shown Symbols Table of ContentsFire and Explosion Hazard Mounting bracket InstallationTypical Installations Mounting BracketSteps 2 through 6 are the Flushing Procedure Pressure Relief ProcedureInstallation Procedure Pre-Installation Procedure309377 Model shown has Bend rigid Extension GroundingKeypad Buttons SetupManual / Reset and Auto / Reset TermsSelecting Dispensing Options Resettable TotalUnits of Measurement Fluid Quarts Liters Auto Preset AmountCalibration Factor Calibration NumberThis menu, you can change the shut-off default amount Shut-Off Default AmountChecking Segments in the Display Dispensing Fluid in Manual ModeOperation Locking and Unlocking the TriggerViewing Totals Dispensing Fluid in Auto ModeReplacing the Filter on TroubleshootingProblem Cause Solution Battery onAutomatic Nozzle on Installation ProcedureSee in Installation Proce Rings. See Servicing the ValveErr Error Code Cause SolutionShut-off Default Amount section See the Auto Preset AmountReplacing the Battery ServiceReplacing the Filter Replacing the Automatic Nozzle Servicing the ValveDescription Qty Parts ListIncludes 16a to 16e, 25, Parts Drawing Meter housingTechnical Data Dimensional Drawing Graco Information Graco Standard WarrantyToll Free 612--623--6928 612--378--3590 Fax