Setup
Calibration Factor
In this menu, you can recalibrate the meter for different fluids.
1.If you have not already entered the dispensing options menus, do steps 1 and 2 in Selecting Dispensing Options on page 8.
2.Press the Auto/Reset button repeatedly until CAL blinks and the current calibration factor is dis- played to indicate that you are in the Calibration menu.
3.With CAL blinking, you can press the Auto/Reset button and choose not to change the calibration factor, which advances to the Auto Preset Amount menu.
OR
You can recalibrate the meter as follows:
3a. If the unit of measurement is liters, dispense exactly one liter of fluid into a calibrated
After dispensing, the displayed number is the new calibration factor. The new calibration factor must be within 20 percent of the fac- tory default value [in the range of
The following table lists approximate calibra- tion factors for different fluids. Your calibra- tion number may vary slightly due to temper- ature or flow rate.
| Calibration Number | ||
Fluid |
|
| |
Quarts | Liters | ||
| |||
|
|
| |
oil | 368 | 389 | |
|
|
| |
gear lube | 368 | 389 | |
|
|
| |
automatic | 368 | 389 | |
transmission |
|
| |
fluid |
|
| |
|
|
| |
antifreeze | 347 | 367 | |
|
|
|
Calibration factors at 70_ F (21_ C) at 2.0 gpm (7.6 lpm).
3b. Press the Auto/Reset button to store the new calibration factor and advance to the Auto Preset Amount menu.
Auto Preset Amount
In this menu, you can specify an amount to be dis- played when you enter the Auto dispense mode. Typically, you would enter the amount you most fre- quently dispense.
1.If you have not already entered the dispensing options menus, do steps 1 and 2 in Selecting Dispensing Options on page 8.
2.Press the Auto/Reset button repeatedly until AUTO blinks and the auto preset amount in memory is displayed to indicate that you are in the Auto Preset Amount menu. This is the amount that is displayed when the Auto/Reset button is pressed during normal operation.
3.With AUTO blinking and the stored auto preset amount displayed, as shown below, do ONE of the following two options:
D Enter a new auto preset amount by pressing the 10 button to change the 10s digit,
the 1.0 button to change the 1s digit, and the 0.1 button the change the first decimal digit.
In the figure below, the arrows point from the num- bered buttons on the keypad to the corresponding digits in the display.
NOTE: If you press and hold the 10, 1.0, or 0.1 but- tons, the digits advance rapidly.
To store the displayed auto preset amount in memory and advance to the Shut-Off Default Amount menu, press the Auto/Reset button.
OR
DPress the Auto/Reset button.
The currently displayed auto preset amount is retained, and the display advances to the
GAL
AUTO
! CAUTION
To prevent overfills and spills
D Do not obstruct the trigger D Do not operate below 32_ F (0_ C) D Do not leave unattended D Read instruction manual
Maximum Working Pressure 7 MPa (70 bar, 1000 PSI)
06044A