Installation

10.Thread the sealing nut (5c, 6c, or 7c) onto the extension (5a) or street elbow (6d or 7d), thread the extension or elbow in at least three full turns, position it for proper alignment, and tighten the sealing nut. The PTFE seal on the sealing nut must face the valve housing. See Fig. 4.

NOTE: The flexible extension (6a) can also be threaded directly into the meter outlet without the street elbow or sealing nut. See the note in the Parts Drawing on page 19.

11.Thread the new nozzle (5b, 6b, or 7b) onto the extension, and, with an open-end adjustable wrench, tighten it firmly. See Fig. 4.

NOTE: Only tighten the nozzle with the wrench on the flats of the nozzle bushing. Do not disas- semble the bushing from the nozzle. Disas- sembly will affect the performance of the nozzle.

WARNING

Do not use Graco’s old nozzle (Part No. 203655) or any other manual shut-off nozzle on the PM5 extension. You must use the new automatic nozzle that is provided with the PM5, or the meter could be damaged. Do not use any sealant material.

12.Open all dispense position shut-off valves, and start the pump to pressurize the system. See the Operation section for proper operation of meter.

13.To ensure dispensing accuracy, purge all air from the fluid lines and dispense valve before you use it. Set the system flow to the desired flow rate, which is typically 1.5 gpm. Do not exceed a 5-gpm flow rate.

Slide onto hose before connecting. 4

hose fitting

3

TI0328

Fig. 3

6 309377

Model shown has

75_ bend rigid

extension

hose

4

5c

5a

nozzle bushing

Nozzle is not serviceable.

5b

TI0327

Fig. 4

Grounding

Proper grounding is an essential part of maintaining a safe system.

To reduce the risk of static sparking, ground all system components according to local and national electrical codes. Refer to the user manuals for the pump and other system components, and ground the following:

DPump: Follow the manufacturer’s recommend- ations.

DAir and Fluid hoses: Use only grounded hoses.

DAir compressor: Follow the manufacturer’s recom- mendations.

DFluid supply container: Follow the local code.

To maintain grounding continuity when flushing or relieving pressure, always hold a metal part of the valve firmly to the side of a grounded metal pail, then trigger the valve.

Image 6
Contents Instructions -- Parts List Important Safety instructionsModel 238511 shown Table of Contents SymbolsFire and Explosion Hazard Mounting Bracket InstallationTypical Installations Mounting bracketPre-Installation Procedure Pressure Relief ProcedureInstallation Procedure Steps 2 through 6 are the Flushing ProcedureGrounding 309377 Model shown has Bend rigid ExtensionTerms SetupManual / Reset and Auto / Reset Keypad ButtonsResettable Total Selecting Dispensing OptionsUnits of Measurement Calibration Number Auto Preset AmountCalibration Factor Fluid Quarts LitersShut-Off Default Amount This menu, you can change the shut-off default amountLocking and Unlocking the Trigger Dispensing Fluid in Manual ModeOperation Checking Segments in the DisplayDispensing Fluid in Auto Mode Viewing TotalsBattery on TroubleshootingProblem Cause Solution Replacing the Filter onRings. See Servicing the Valve Installation ProcedureSee in Installation Proce Automatic Nozzle onSee the Auto Preset Amount Error Code Cause SolutionShut-off Default Amount section ErrService Replacing the BatteryReplacing the Filter Servicing the Valve Replacing the Automatic NozzleParts List Description QtyIncludes 16a to 16e, 25, Meter housing Parts DrawingTechnical Data Dimensional Drawing Graco Standard Warranty Graco InformationToll Free 612--623--6928 612--378--3590 Fax