Section 5 • Maintenance/Service
shaft seal cavity in the compressor housing. Apply clean compressor oil to the shaft seal seating area on input shaft.
8.Lubricate the inside area of the rotating seal with clean compressor lubricating oil, do not wipe or touch the face of the rotating portion of the seal. Align the slot in the rotating seal with the drive pin on the compressor input shaft, see Figure
Figure 5-30. Command Shaft Seal Installation
5 – 30 | VSG/VSSG • Installation, Operation and Maintenance Manual •Vilter/Emerson • 35391SSG |