Section 5 • Maintenance/Service
compressor shaft.
12. Remove hub and key from compressor shaft.
INSTALLATION
13.Install key and hub on compressor shaft as noted during removal.
14.Install set screw in compressor hub to secure key in keyway, see Table
15.Install clamping bolts to secure hub on compressor shaft. Tighten clamping bolts, see Table
16.Install key and hub on motor shaft as noted during removal. Allow gap to install coupling sleeve.
17.Install coupling sleeve on hubs. Position hub on motor shaft on coupling sleeve as noted during removal.
18.Install set screw in compressor hub to secure key in keyway. Tighten set screw, see Table
19.Install clamping bolts to secure hub to motor shaft. Tighten clamping bolts, see Table
Compressor Replacement
Notify Vilter prior to performing a compressor replace- ment. See Warranty instructions in Section 7.
REMOVAL
To replace a compressor on a unit, proceed with the fol- lowing steps:
NOTICE
Dispose of the oil in a appropriate manner following all Local, State and Federal ordinances regarding the disposal of used oil.
1.Shut down and isolate the compressor unit, see Compressor Unit Isolation for Maintenance and Service procedure.
NOTE
Note location of cables to aid in installation.
2.Disconnect all cables from sensors on compressor and actuators.
Table 5-6. Clamping Bolts and Set
Screw Torque Specifications
| Type C |
| |
Coupling | |||
Size | Clamping | Key Set | |
| Bolts | Screw | |
|
|
|
|
6 | 13 (18) |
|
|
|
|
|
|
7 | 13 (18) |
|
|
|
|
|
|
8 | 23 (31) |
| 13 (18) |
|
|
| |
9 | 23 (31) |
| |
|
|
1050 (68)
1150 (68)
3.Remove drive coupling, see appropriate Drive Coupling Replacement procedure.
4.If equipped with
5.Remove center member, see Drive Coupling Removal procedure.
6.Using appropriate drain pan, drain oil by removing drain plugs from under compressor housing and discharge manifold. Allow oil to completely drain.
7.Remove all oil lines from the compressor.
8.Support suction line with appropriate supporting equipment.
9.Remove nuts and bolts securing suction strainer/ check valve assembly to suction stop valve and compressor.
10.Using appropriate lifting device, remove suction strainer/check valve assembly from compressor.
11.Remove nuts and bolts securing discharge pipe to compressor and oil separator, see Figure
12.Remove discharge pipe and gaskets from compres- sor and oil separator.
13.Remove nuts, flat washers, lock washers and studs securing compressor to frame.
14.Remove any additional lines and/or components to allow removal of compressor as required.
15.Install appropriate lifting eyes on top of compressor.
16.Using appropriate lifting device and additional
5 – 14 | VSG/VSSG • Installation, Operation and Maintenance Manual •Vilter/Emerson • 35391SSG |