Table 3-2. Maximum Allowable Flange Loads
Nozzle Dia. (in.) | Fz (lbf) | Fy (lbf) | Fx | Mzz | Myy | Mxx |
|
|
|
|
|
|
|
4 | 400 | 400 | 400 | 300 | 300 | 300 |
|
|
|
|
|
|
|
6 | 600 | 600 | 600 | 500 | 500 | 500 |
|
|
|
|
|
|
|
8 | 900 | 900 | 900 | 1000 | 1000 | 1000 |
|
|
|
|
|
|
|
10 | 1200 | 1200 | 1200 | 1200 | 1200 | 1200 |
|
|
|
|
|
|
|
12 | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 |
|
|
|
|
|
|
|
14 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 |
|
|
|
|
|
|
|
|
| HANGER |
CUSTOMER SUPPORTS | 5 PIPE | DISCHARGE |
WHEN CHECK VALVE | DIAMETERS | |
IS MOUNTED HERE |
| LINE |
5 PIPE |
| |
|
| |
| DIAMETERS | |
5 PIPE |
| |
| DIAMETERS | |
DIAMETERS |
| |
|
| |
|
| CHECK |
|
| VALVE |
|
| SUCTION |
| CUSTOMER | LINE |
| SUPPORT | Y |
|
| |
| Z | X |
X
Z
CUSTOMER
SUPPORT
Y
Figure
VSG/VSSG • Installation, Operation and Maintenance Manual •Vilter/Emerson • 35391SSG | 3 – 11 |