Spectra UL633-14 Using the Rotation mode, Using the Scan mode, Manual mode, Pointing mode

Page 11

Use button 1 or 2 (Plus or Minus) to set the desired digit.

The laser will self-level to the required grade position after confirming the grade change with button 4.

Note: The bubble symbols at the laser’s LCD will flash until the laser has been self-leveled to the requested grade position.

Using the Rotation mode

Repeatedly pressing the button 4 toggles through 0, 80, 200, 600, 900 rpm regardless if the unit is in automatic or manual mode.

At 0 rpm, the beam stops automatically close to the +Y- axis center position (pipe laying over the top).

When set up horizontally in automatic or grade mode, using buttons 5/8 increases/decreases rotor speed from 0 to 80 and then up to 900 rpm continuously in 10 rpm increments.

Pointing mode

At 0 rpm, buttons 6/7 move the beam to the left/right side. When set up vertically at 0 rpm, button 5/8 move the beam clockwise/counterclockwise.

Note: Press and hold button 4 for three seconds to change the unit from rotation mode (default) into scan mode.

Using the Scan mode

Press and hold button 4 at the Standard Display for three seconds to change the unit into scan mode.

Quickly press and release button 4 to toggle between the pre-selected scan sizes 5, 15, 45, 90, 180 degrees and 0; regardless if the unit is in automatic or manual mode.

When working in horizontal automatic mode, press and hold button 5/8 to increase/decrease the line size in 5 degrees increments. Press and hold button 6/7 moves the scan line to the right/left direction. When used in automatic vertical mode, pressing and holding button 5/8 moves the scan line counterclockwise/ clockwise. When set up vertical, pressing and holding button 6/7 moves the scan line into the right/left direction regardless if in automatic or manual mode.

Note: Press and hold button 4 for three seconds to change the unit back to rotation mode (default) mode.

Manual mode

Pressing and releasing button 3 at the Standard Display activates/deactivates the manual mode regardless if set up horizontal or vertical.

Manual mode is indicated by horizontal lines next to the axes symbols. An additional bubble helps to adjust the laser on the cross axis when set up vertical.

In Manual mode (horizontal), the Y-axis can be sloped by pressing the Up-(5) and Down-Arrow-(8) buttons on the laser‘s keypad or the remote control. Additionally, the X-axis can be sloped by pressing the Left-(6) and Right-(7) Arrow-buttons on the laser or remote control.

In vertical mode, the up and down arrow buttons adjust the Z-axis slope, and the left and right arrow buttons align the laser beam to the right/left side.

To resume automatic self-leveling mode, press the manual button again.

6

Image 11
Contents Page Page Page Q104735 Rev. A01/12 Asia-Pacific North-Latin AmericaAfrica & Middle East EuropeTable of Contents Components For Your SafetyBatteries HOW to USE the Laser System Powering the LaserPowering the RC603 Recharging the BatteriesStandard Display Laser SetupFeatures and Functions Turning On/Off the laserZ-grade entering Digit Select mode Standard Features Z-grade entering Step and Go modePointing mode Using the Rotation modeUsing the Scan mode Manual modeSpecial Menu Features Menu Functions Radio controlled With the photocell on the bottom side Automatic PlaneLok modeAutomatic Grade Match Automatic Axis Alignment Manual Grade MatchActivating/Deactivating Standby mode Manual Spot Search modeCentering the Rotor Setting MenuService Start Reference CheckRF Connectivity RC603 Service menu offers additional features RF IR optionsSpecial Features Vertical Setup Axis Automatic Spot Align Axis Automatic Spot Match Axis Automatic Spot LokLine Scan PairingPairing Mask Mode Grade Entry Grade Display HI-Alert Information Set Password Password On/OffMask mode Pairing the transmitter with remote controlPairing the transmitter with receiver HI-alert Selection Grade EntryGrade Display Sensitivity SelectionUser Name Set PasswordPassword On/Off Password onChecking Calibration of the Z-vertical Axis CalibrationChecking Calibration of the Y- and X-Axes Error codes Description Solution TroubleshootingComponents SF601 SF601 User GuideUsing the SpotFinder SF601 for vertical UL applications Powering the SF601SF601 Features and Functions SF601 Manual/Display Mode Protecting the Environment Cleaning and MaintenanceProtecting the Unit Spot Finder SF601 Technical DataRemote Control RC603 UL633Dayton, Ohio UL633 and RC603/SF601 Declaration of ConformityELECTRO-MAGNETIC Compatibility Trimble Kaiserslautern GmbH