LASER SETUP
Position the laser horizontally (tripod mount and rubber feet downward!) on a stable platform, wall mount or tripod at the desired elevation.
The laser recognizes automatically whether it is used horizontally or vertically when switched on.
Turning On/Off the laser
Press the power button to turn On/Off the laser.
Note: Depending on the setup (horizontal or vertical) and if a grade value has been dialed in, the unit starts the temperature/reference check while the thermometer symbol is flashing.
When the temperature/reference check has been finished, the standard display appears and the bubble symbols flash until
If the
A bubble symbol helps to adjust the unit at the cross axis when set up vertical for automatic Spot Align or in vertical manual mode.
Features and Functions
Standard Display |
| |
The remote control mirrors the functionality of the UL keypad | HI alert function is activated | |
Battery status laser | ||
Mask selection | Battery Status Remote Control | |
Rotation speed/Scan angle | Status Radio Connectivity | |
Fan Beam is activated | ||
|
Button 1: Quickly press and release starts the MENU entry.
Button 2: Quickly press and release starts the grade entering mode.
Button 3: Quickly press and release activates/ deactivates the manual mode.
Button 4: Quickly press and release to toggle through the
Button 5, 8: up/down arrow buttons.
Button 6, 7: left/right arrow buttons.
Button 9: ON/OFF button - press for 1 second to turn on the unit; press and hold for 2 seconds to turn off the unit.
Leveling/Standby – LED (green/red)
4