Line Scan

Line Scan centers the rotor horizontally and can be used to align the plumb beam to a desired horizontal position. Press and release the MENU button at the Standard Display and select Line Scan. Pressing and releasing button 4 activates the Line Scan mode while the rotor checks the limits of the X- axis and stops at the center position.

Pressing button 3 (ESC) stops the movement and changes the unit into manual mode. Corrections up and down can be done using button 5/8; for left/right corrections use button 6/7.

Press and release the manual button to change the unit back to full automatic mode.

Beam Plunge

Beam Plunge centers the rotor vertically and can be used to align the plumb beam to a desired vertical position, e.g., when doing Interior layout.

Press and release the MENU button at the Standard Display and select Beam Plunge. Pressing and releasing button 4 activates the Beam Plunge mode while the rotor checks the limits of the

Y- axis and stops at the center position.

Pressing button 3 (ESC) stops the movement and changes the unit into manual mode. Corrections up and down can be done using button 5/8; for left/right corrections use button 6/7.

Press and release the manual button to change the unit back to full automatic mode.

Setting Menu

Press and release the MENU button at the Standard Display and select Settings.

Press and release button 4 to open the Setting Menu; select the desired function then press button 4 to open the selected submenu function OR start the selected function.

The Setting Menu offers the following functions:

 

 

 

 

 

 

 

 

 

 

 

Pairing

Mask Mode

Grade Entry

Grade Display

Sensitivity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HI-Alert

Information

Set Password

Password On/Off

RF-Channel

Pairing

When in Settings, press and release button 4 to open the Pairing menu. The display shows the currently paired units (up to two receivers and two remote controls). If already 2 remote controls have been paired, one of them has to be deleted using button 1 (CLR).Turn on the RC603 and select the Pairing menu and press button 4.

The UL633 pairs now automatically with the new remote control.

14

Image 19
Contents Page Page Page Q104735 Rev. A01/12 Asia-Pacific North-Latin AmericaAfrica & Middle East EuropeTable of Contents Components For Your SafetyBatteries HOW to USE the Laser System Powering the LaserPowering the RC603 Recharging the BatteriesStandard Display Laser SetupFeatures and Functions Turning On/Off the laserZ-grade entering Digit Select mode Standard Features Z-grade entering Step and Go modePointing mode Using the Rotation modeUsing the Scan mode Manual modeSpecial Menu Features Menu Functions Radio controlled Automatic Grade Match Automatic PlaneLok modeWith the photocell on the bottom side Automatic Axis Alignment Manual Grade MatchActivating/Deactivating Standby mode Manual Spot Search modeCentering the Rotor Setting MenuService Start Reference CheckSpecial Features Vertical Setup Axis Automatic Spot Align RC603 Service menu offers additional features RF IR optionsRF Connectivity Axis Automatic Spot Match Axis Automatic Spot LokLine Scan PairingPairing Mask Mode Grade Entry Grade Display HI-Alert Information Set Password Password On/OffPairing the transmitter with receiver Pairing the transmitter with remote controlMask mode HI-alert Selection Grade EntryGrade Display Sensitivity SelectionUser Name Set PasswordPassword On/Off Password onChecking Calibration of the Y- and X-Axes CalibrationChecking Calibration of the Z-vertical Axis Error codes Description Solution TroubleshootingComponents SF601 SF601 User GuideSF601 Features and Functions Powering the SF601Using the SpotFinder SF601 for vertical UL applications SF601 Manual/Display Mode Protecting the Unit Cleaning and MaintenanceProtecting the Environment Spot Finder SF601 Technical DataRemote Control RC603 UL633Dayton, Ohio UL633 and RC603/SF601 Declaration of ConformityELECTRO-MAGNETIC Compatibility Trimble Kaiserslautern GmbH