Powering the SF601

1.Open the battery door pulling the battery door latch.

The SF601will be shipped with alkaline batteries.

Rechargeable batteries can be used optional but need to be charged externally

2.Insert four AA batteries noting the plus (+) and minus (-) diagrams inside on the battery door.

3.Close the battery door. Push down until it “clicks” into the locked position.

SF601 - Features and Functions

1. Power/Mode Button: Press and release the power button to turn ON the SF601. All display LED’s will light for 1.0 sec.

Press and hold power button for >1 sec. to turn OFF the SF601. After 1 sec. all display LED’s will light 1.0 sec.

Note: Wurde der SF601 eingeschaltet, wird durch kurzes Drücken der Ein-Aus-Taste die Fanbeam-Linse aktiviert/deaktiviert (eine vorher gestartete Automatikfunktion wird sofort gestoppt).

LED’s:

2. LED1:

solid green when SF601 is on and battery OK blinking red if battery voltage is 3,8V<V bat <4V solid red if battery voltage is <3,8V;

4

SF601 turns off automatically after 5 min.

3. Mode LED2:

yellow solid: automatic mode

flashing: none or lost signal

off: manual mode

3

1

4. Direction LEDs red:

2

 

Manual mode: pointing towards the center of the plumb beam.

All 4 LEDs are solid red when the beam is centered.

Automatic Spot Lock mode: solid for 5 min., then LED’s flash every 5 seconds.

Using the SpotFinder SF601 for vertical UL applications

With the UL633 using IR connection, the SF601 can be used in three different automatic modes Automatic- Spot Alignment, SpotLok and Spot-Match and in addition in a manual/display (Spot Search) mode to detect the plumb beam (fan beam).

Automatic-Spot Alignment: SF601 guides the beam to the target point in the horizontal axis, while the Z-axis grade value will be maintained. Used for first and second day alignment (pipe laying applications).

21

Image 26
Contents Page Page Page Q104735 Rev. A01/12 Europe North-Latin AmericaAfrica & Middle East Asia-PacificTable of Contents For Your Safety ComponentsRecharging the Batteries HOW to USE the Laser System Powering the LaserPowering the RC603 BatteriesTurning On/Off the laser Laser SetupFeatures and Functions Standard DisplayStandard Features Z-grade entering Step and Go mode Z-grade entering Digit Select modeManual mode Using the Rotation modeUsing the Scan mode Pointing modeSpecial Menu Features Menu Functions Radio controlled With the photocell on the bottom side Automatic PlaneLok modeAutomatic Grade Match Manual Grade Match Automatic Axis AlignmentManual Spot Search mode Activating/Deactivating Standby modeStart Reference Check Setting MenuService Centering the RotorRF Connectivity RC603 Service menu offers additional features RF IR optionsSpecial Features Vertical Setup Axis Automatic Spot Align Axis Automatic Spot Lok Axis Automatic Spot MatchHI-Alert Information Set Password Password On/Off PairingPairing Mask Mode Grade Entry Grade Display Line ScanMask mode Pairing the transmitter with remote controlPairing the transmitter with receiver Sensitivity Selection Grade EntryGrade Display HI-alert SelectionPassword on Set PasswordPassword On/Off User NameChecking Calibration of the Z-vertical Axis CalibrationChecking Calibration of the Y- and X-Axes Troubleshooting Error codes Description SolutionSF601 User Guide Components SF601Using the SpotFinder SF601 for vertical UL applications Powering the SF601SF601 Features and Functions SF601 Manual/Display Mode Protecting the Environment Cleaning and MaintenanceProtecting the Unit UL633 Technical DataRemote Control RC603 Spot Finder SF601Dayton, Ohio Trimble Kaiserslautern GmbH Declaration of ConformityELECTRO-MAGNETIC Compatibility UL633 and RC603/SF601