Spectra UL633-14 manual Troubleshooting, Error codes Description Solution

Page 24

Troubleshooting

Any error message can be deleted with a short press of button 4 (OK). The table shows the related description and possible solutions. The next service center should be contacted if a different error message as shown at the table will be displayed.

Error codes

Description

Solution

 

 

 

21

Temporary EEprom problem

Repeat pairing and re-enter the

 

 

customer settings

120

HI alert - Unit Heigt changed

Check laser beam elevation after

 

 

deleting the HI alert

 

 

 

130

Mechanical Limit during Axis

Re-align the closer to the

 

Alignment, Grade Match or Spot

alignment point; check if existing

 

Match

slope is above +/-25%

 

 

 

131

Rake Angle Limit

Re-align the unit closer to the

 

 

alignment point

 

 

 

140

Laser beam blocked

Make sure there are no

 

 

obstacles between the

 

 

transmitter and the HL750 or

 

 

SF601

 

 

 

141

Time Out - Function could not be

Check radio operating range/

 

completed in the allowed time

connection; check stable laser

 

 

setup

150

No receiver - Receiver not

Make sure the receiver is on and

 

available for single axis

paired

 

automatic function

 

151

No receivers - Both receivers

Make sure both receivers are on

 

are not available for automatic

and paired

 

alignment function

 

152

No receiver - The laser searched

Check the operating range for

 

for the receiver but could not

auto function and restart the auto

 

find it

alignment

 

 

 

153

Lost Receiver - The laser

Check the operating range for

 

searched and found the receiver

auto function and restart the auto

 

but then lost it

alignment

 

 

 

160

X,Y or Z level sensor defect

Contact service center

 

 

 

19

Image 24
Contents Page Page Page Q104735 Rev. A01/12 North-Latin America Africa & Middle EastEurope Asia-PacificTable of Contents For Your Safety ComponentsHOW to USE the Laser System Powering the Laser Powering the RC603Recharging the Batteries BatteriesLaser Setup Features and FunctionsTurning On/Off the laser Standard DisplayStandard Features Z-grade entering Step and Go mode Z-grade entering Digit Select modeUsing the Rotation mode Using the Scan modeManual mode Pointing modeSpecial Menu Features Menu Functions Radio controlled Automatic PlaneLok mode Automatic Grade MatchWith the photocell on the bottom side Manual Grade Match Automatic Axis AlignmentManual Spot Search mode Activating/Deactivating Standby modeSetting Menu ServiceStart Reference Check Centering the RotorRC603 Service menu offers additional features RF IR options Special Features Vertical Setup Axis Automatic Spot AlignRF Connectivity Axis Automatic Spot Lok Axis Automatic Spot MatchPairing Pairing Mask Mode Grade Entry Grade DisplayHI-Alert Information Set Password Password On/Off Line ScanPairing the transmitter with remote control Pairing the transmitter with receiverMask mode Grade Entry Grade Display Sensitivity Selection HI-alert SelectionSet Password Password On/OffPassword on User NameCalibration Checking Calibration of the Y- and X-AxesChecking Calibration of the Z-vertical Axis Troubleshooting Error codes Description SolutionSF601 User Guide Components SF601Powering the SF601 SF601 Features and FunctionsUsing the SpotFinder SF601 for vertical UL applications SF601 Manual/Display Mode Cleaning and Maintenance Protecting the UnitProtecting the Environment Technical Data Remote Control RC603UL633 Spot Finder SF601Dayton, Ohio Declaration of Conformity ELECTRO-MAGNETIC CompatibilityTrimble Kaiserslautern GmbH UL633 and RC603/SF601