4.Press and release the MENU button at the Standard Display and select Axis Align.
5.Select the desired axis then press button 4 to start Axis Align.
Note: Adjusting the receiver into the beam before starting the automatic Axis Alignment reduces the time needed for finishing the alignment.
Selecting the menu icon „View Axis Angle“ shows the alignment angle after an axis alignment has been completed. This function can be used to measure an angle difference between two direction hubs in a range up to max. 80° by performing two axis alignments in sequence.
The menu icon „Axis Angle Input“ selection allows to dial in an axis angle where the axis direction will be aligned too after a first axis alignment has been done. Two rows are available for typing in axis angle values.
Button 5 and 8 can be used to toggle between both rows. Changing the sign and numbers can be done using the buttons 1 and 2.
Press and release button 4 to confirm the selected axis angles. The axes will be adjusted while the display falls back to the main Menu.
Press and release button 3 (ESC) to exit the Angle functions.
Manual Spot Search mode
The Spot Search mode is used for detecting the plumb beam manually using the Spot Finder SF601 and can be activated in horizontal and vertical automatic and manual mode.
Press and release the MENU button at the Standard Display and select Spot Search.
Pressing button 4 activates the fan beam while the rotation speed changes to 900 rpm and the unit goes back to the standard display.
The 4 red LEDs around the center hole guide the user to the plumb beam‘s center position - all 4 LEDs on => confirmation the SF601 has been set to the correct center position.
Note: Manual Spot Search can also be activated any time by turning on the Spot Finder SF601. Turning Off the SF601 deactivates the Spot Search mode immediately by deactivating the fan beam.
Activating/Deactivating Standby mode
Press and release the MENU button at the Standard Display and select Standby.
Pressing and releasing button 4 activates the Standby mode.
The
To deactivate Standby mode and restore full operation of the laser, press and release button 4.