Spectra UL633-14 manual Manual Spot Search mode, Activating/Deactivating Standby mode

Page 15

4.Press and release the MENU button at the Standard Display and select Axis Align.

5.Select the desired axis then press button 4 to start Axis Align.

Note: Adjusting the receiver into the beam before starting the automatic Axis Alignment reduces the time needed for finishing the alignment.

Selecting the menu icon „View Axis Angle“ shows the alignment angle after an axis alignment has been completed. This function can be used to measure an angle difference between two direction hubs in a range up to max. 80° by performing two axis alignments in sequence.

The menu icon „Axis Angle Input“ selection allows to dial in an axis angle where the axis direction will be aligned too after a first axis alignment has been done. Two rows are available for typing in axis angle values.

Button 5 and 8 can be used to toggle between both rows. Changing the sign and numbers can be done using the buttons 1 and 2.

Press and release button 4 to confirm the selected axis angles. The axes will be adjusted while the display falls back to the main Menu.

Press and release button 3 (ESC) to exit the Angle functions.

Manual Spot Search mode

The Spot Search mode is used for detecting the plumb beam manually using the Spot Finder SF601 and can be activated in horizontal and vertical automatic and manual mode.

Press and release the MENU button at the Standard Display and select Spot Search.

Pressing button 4 activates the fan beam while the rotation speed changes to 900 rpm and the unit goes back to the standard display.

The 4 red LEDs around the center hole guide the user to the plumb beam‘s center position - all 4 LEDs on => confirmation the SF601 has been set to the correct center position.

Note: Manual Spot Search can also be activated any time by turning on the Spot Finder SF601. Turning Off the SF601 deactivates the Spot Search mode immediately by deactivating the fan beam.

Activating/Deactivating Standby mode

Press and release the MENU button at the Standard Display and select Standby.

Pressing and releasing button 4 activates the Standby mode.

The self-leveling will be stopped and the beam will be turned off while the HI alert is still active. The display shows the standby symbol and the Level/Standby LED flashes red every 5 seconds.

To deactivate Standby mode and restore full operation of the laser, press and release button 4.

10

Image 15
Contents Page Page Page Q104735 Rev. A01/12 Asia-Pacific North-Latin AmericaAfrica & Middle East EuropeTable of Contents Components For Your SafetyBatteries HOW to USE the Laser System Powering the LaserPowering the RC603 Recharging the BatteriesStandard Display Laser SetupFeatures and Functions Turning On/Off the laserZ-grade entering Digit Select mode Standard Features Z-grade entering Step and Go modePointing mode Using the Rotation modeUsing the Scan mode Manual modeSpecial Menu Features Menu Functions Radio controlled Automatic PlaneLok mode Automatic Grade MatchWith the photocell on the bottom side Automatic Axis Alignment Manual Grade MatchActivating/Deactivating Standby mode Manual Spot Search modeCentering the Rotor Setting MenuService Start Reference CheckRC603 Service menu offers additional features RF IR options Special Features Vertical Setup Axis Automatic Spot AlignRF Connectivity Axis Automatic Spot Match Axis Automatic Spot LokLine Scan PairingPairing Mask Mode Grade Entry Grade Display HI-Alert Information Set Password Password On/OffPairing the transmitter with remote control Pairing the transmitter with receiverMask mode HI-alert Selection Grade EntryGrade Display Sensitivity SelectionUser Name Set PasswordPassword On/Off Password onCalibration Checking Calibration of the Y- and X-AxesChecking Calibration of the Z-vertical Axis Error codes Description Solution TroubleshootingComponents SF601 SF601 User GuidePowering the SF601 SF601 Features and FunctionsUsing the SpotFinder SF601 for vertical UL applications SF601 Manual/Display Mode Cleaning and Maintenance Protecting the UnitProtecting the Environment Spot Finder SF601 Technical DataRemote Control RC603 UL633Dayton, Ohio UL633 and RC603/SF601 Declaration of ConformityELECTRO-MAGNETIC Compatibility Trimble Kaiserslautern GmbH