Z-axis Automatic Spot Lok

Automatic SpotLok (like PlaneLok) can be used to align and hold the plumb beam automatically to the SF601’s center point and continuously adjusting the Z- and X- axis until exiting this mode. The UL looks always to the center position of the SF601 and re-adjusts the beam immediately to the center to avoid any setup/alignment drift caused by vibrations or temperature influences (e.g. when working on concrete pads, facade applications). Using Spot Lok, the plumb beam can be aligned automatically to one direction hub (up to 80 m (260 ft) located in front of the plumb beam.

1.Set up the laser over the start point.

2.Place the SF601 Spot Finder at the second reference point.

3.Press and release the MENU button at the Standard Display, select Spot Lok and start the function using button

4 (fan beam will be activated).

Note: Spot Lok can also be started via infrared using the

RC603.

Note: The display falls back to the standard display while a Spot Finder and lock icon is flashing. The plumb beam will be automatically aligned to the center of the SF601.

4.After Spot Lok is complete all 4 red LEDs at the SF601 are on and the icons stop flashing. The transmitter‘s plumb beam is always checking for perfect alignment to the center of the SF601. All 4 LEDs flash every 5 seconds to confirm the correct alignment.

Note: Automatic Spot Lok can be exited any time by pressing and releasing button 3 (ESC).

Z-axis Automatic Spot Match

Automatic-Spot-Matchcan be used for measuring an unknown grade value between two existing elevations e. g., in an existing pipe which needs to be replaced or an open trench with an unknown grade value.

The plumb beam will be automatically aligned to the SF601 center point (Z- and X- axis) and switches back to automatic Z-axis grade mode while displaying the measured Z-grade value.

Using Spot Match, the plumb beam can be aligned automatically to one direction hub (up to 80 m (260 ft) located in front of the plumb beam..

1.Set up the laser over the start point, e.g., at the first pipe or trench start point.

2.Place the SF601 Spot Finder at the last pipe or end of the trench.

3.Press and release the MENU button at the Standard Display, select Spot Match and start the function using button 4 (fan beam will be activated)..

Note: Spot Match can also be started via infrared using the RC603.

Note: The display falls back to the standard display while a Spot Finder and angle symbol is flashing. The plumb beam will be automatically aligned to the center of the SF601.

4.When Spot Match has been completed, the fan beam will be turned off and the UL calculates the grade value between both elevation points. The calculated grade value will be displayed at the UL‘s and RC‘s display.

Note: Automatic Spot Match can be exited any time by pressing and releasing button 3 (ESC).

13

Image 18
Contents Page Page Page Q104735 Rev. A01/12 Europe North-Latin AmericaAfrica & Middle East Asia-PacificTable of Contents For Your Safety ComponentsRecharging the Batteries HOW to USE the Laser System Powering the LaserPowering the RC603 BatteriesTurning On/Off the laser Laser SetupFeatures and Functions Standard DisplayStandard Features Z-grade entering Step and Go mode Z-grade entering Digit Select modeManual mode Using the Rotation modeUsing the Scan mode Pointing modeSpecial Menu Features Menu Functions Radio controlled Automatic PlaneLok mode Automatic Grade MatchWith the photocell on the bottom side Manual Grade Match Automatic Axis AlignmentManual Spot Search mode Activating/Deactivating Standby modeStart Reference Check Setting MenuService Centering the RotorRC603 Service menu offers additional features RF IR options Special Features Vertical Setup Axis Automatic Spot AlignRF Connectivity Axis Automatic Spot Lok Axis Automatic Spot MatchHI-Alert Information Set Password Password On/Off PairingPairing Mask Mode Grade Entry Grade Display Line ScanPairing the transmitter with remote control Pairing the transmitter with receiverMask mode Sensitivity Selection Grade EntryGrade Display HI-alert SelectionPassword on Set PasswordPassword On/Off User NameCalibration Checking Calibration of the Y- and X-AxesChecking Calibration of the Z-vertical Axis Troubleshooting Error codes Description SolutionSF601 User Guide Components SF601Powering the SF601 SF601 Features and FunctionsUsing the SpotFinder SF601 for vertical UL applications SF601 Manual/Display Mode Cleaning and Maintenance Protecting the UnitProtecting the Environment UL633 Technical DataRemote Control RC603 Spot Finder SF601Dayton, Ohio Trimble Kaiserslautern GmbH Declaration of ConformityELECTRO-MAGNETIC Compatibility UL633 and RC603/SF601