The RC603 Service menu offers additional features:
RF IR options
Press and release button 4 to confirm the selection and select one of the following options:
RF On; IR auto => Radio on all times; IR will be activated automatically after radio connection has been lost.
RF Off; IR On => Radio turned Off; IR always activated RF On; IR Off => Radio turned On; IR always Off
RF Connectivity
Press and release button 4 to get a status of the current Radio connectivity.
Special Features - Vertical Setup
Z-Axis Automatic Spot Align
The Spot Finder SF601 guides the plumb beam to the target point in the horizontal axis, while the
1.Set up the laser over the start point, e.g., at the first manhole ring.
2.Adjust the display bubble to the centered position.
3.Turn on and attach the SF601 Spot Finder at the desired direction hub.
4.Press and release the MENU button at the Standard Display; select Spot Align and start the function using button 4 (fan beam will be activated).
Note: Spot Align can also be started through the pipe using the RC603 via infrared.
Note: The display falls back to the standard display while a Spot Finder symbol is flashing.
The plumb beam will be automatically aligned to the center of the SF601.
5.After alingment is complete (all 4 red LEDs at the SF601 are on), the plumb beam will move vertically to the previous dialed in
Note: Automatic Spot Align can be exited any time by pressing and releasing button 3 (ESC).
12