Spectra UL633 manual RC603 Service menu offers additional features RF IR options, RF Connectivity

Page 17

The RC603 Service menu offers additional features:

RF IR options

Press and release button 4 to confirm the selection and select one of the following options:

RF On; IR auto => Radio on all times; IR will be activated automatically after radio connection has been lost.

RF Off; IR On => Radio turned Off; IR always activated RF On; IR Off => Radio turned On; IR always Off

RF Connectivity

Press and release button 4 to get a status of the current Radio connectivity.

Special Features - Vertical Setup

Z-Axis Automatic Spot Align

The Spot Finder SF601 guides the plumb beam to the target point in the horizontal axis, while the Z-axis grade value will be maintained. Used for first and second day alignment (pipe laying applications). Using Spot Alignment, the plumb beam can be aligned automatically to one direction hub (up to 80 m (260 ft) located in front of the plumb beam.

1.Set up the laser over the start point, e.g., at the first manhole ring.

2.Adjust the display bubble to the centered position.

3.Turn on and attach the SF601 Spot Finder at the desired direction hub.

4.Press and release the MENU button at the Standard Display; select Spot Align and start the function using button 4 (fan beam will be activated).

Note: Spot Align can also be started through the pipe using the RC603 via infrared.

Note: The display falls back to the standard display while a Spot Finder symbol is flashing.

The plumb beam will be automatically aligned to the center of the SF601.

5.After alingment is complete (all 4 red LEDs at the SF601 are on), the plumb beam will move vertically to the previous dialed in Z-axis grade value.

Note: Automatic Spot Align can be exited any time by pressing and releasing button 3 (ESC).

12

Image 17
Contents Page Page Page Q104735 Rev. A01/12 Africa & Middle East North-Latin AmericaEurope Asia-PacificTable of Contents Components For Your SafetyPowering the RC603 HOW to USE the Laser System Powering the LaserRecharging the Batteries BatteriesFeatures and Functions Laser SetupTurning On/Off the laser Standard DisplayZ-grade entering Digit Select mode Standard Features Z-grade entering Step and Go modeUsing the Scan mode Using the Rotation modeManual mode Pointing modeSpecial Menu Features Menu Functions Radio controlled With the photocell on the bottom side Automatic PlaneLok modeAutomatic Grade Match Automatic Axis Alignment Manual Grade MatchActivating/Deactivating Standby mode Manual Spot Search modeService Setting MenuStart Reference Check Centering the RotorRF Connectivity RC603 Service menu offers additional features RF IR optionsSpecial Features Vertical Setup Axis Automatic Spot Align Axis Automatic Spot Match Axis Automatic Spot LokPairing Mask Mode Grade Entry Grade Display PairingHI-Alert Information Set Password Password On/Off Line ScanMask mode Pairing the transmitter with remote controlPairing the transmitter with receiver Grade Display Grade EntrySensitivity Selection HI-alert SelectionPassword On/Off Set PasswordPassword on User NameChecking Calibration of the Z-vertical Axis CalibrationChecking Calibration of the Y- and X-Axes Error codes Description Solution TroubleshootingComponents SF601 SF601 User GuideUsing the SpotFinder SF601 for vertical UL applications Powering the SF601SF601 Features and Functions SF601 Manual/Display Mode Protecting the Environment Cleaning and MaintenanceProtecting the Unit Remote Control RC603 Technical DataUL633 Spot Finder SF601Dayton, Ohio ELECTRO-MAGNETIC Compatibility Declaration of ConformityTrimble Kaiserslautern GmbH UL633 and RC603/SF601