Standard Features
X-Y-Z-grade entering – Step and Go mode
Quickly press and release button 2 starts the grade entering mode. Both grade values will be shown. Press/release button 1 a grade reverse Y
Press/release button 2 a grade reverse X Press/release button 3 a return to the standard display
Quickly press and release button 4 to confirm the selected grade value and return to the standard display
Press and hold button 6 or 7 (left/right) to change X- axis grade value after the comma; press and hold buttons 6 + 7 simultaneously starts
Press and hold button 5 or 8 (up/down) for changing Y/Z
Note: The speed of the grade value change increases with the amount of time the button is held down.
Note: The grade value for both axes increases in 1.00% increments. When the grade value for either axis reaches its highest amount, the grade value switches to the lowest value for that axis. For example, the value switches from +25% to
The laser will
Note: The bubble symbols at the laser’s LCD will flash until the laser has been
X-Y-Z-grade entering – Digit Select mode
Quickly press and release button 2 starts the grade entering mode. .
Both grade values will be shown.
Press/release button 1 a quick set to 0%
Press/release button 2 a change the sign in front of the grade value
Press/release button 3 a return to the standard display.
Quickly press and release button 4 to confirm the selected grade value and return to the standard display.
Press and release button 5 or 8 (down or up) to move the cursor to the X- or
5