Introduction

Thank you for choosing one of the Spectra Precision Lasers from the Trimble family of precision lasers. The universal laser is an easy-to-use tool that offers accurate horizontal, vertical and sloped laser reference up to 1300 ft (400 m) away using a receiver. The plumb beam can be detected automatically and manually using the additional SpotFinder

For Your Safety

For hazardless and safe operation, read all the user guide instructions.

LASER RADIATION

AVOID DIRECT EYE

EXPOSURE CLASS 3A/3R

LASER PODUCT

Use of this product by people other than those trained on this product may result in exposure to hazardous laser light.

Do not remove warning labels from the unit.

The UL633 is Class 3A/3R (< 5mW, 600 ... 680 nm).

Never look into the laser beam or direct it to the eyes of other people.

Always operate the unit in a way that prevents the beam from getting into people‘s eyes.

If initial service is required, which results in the removal of the outer protective cover, removal must only be performed by factory-trained personnel.

Caution: Use of other than the described user and calibration tools or other procedures may result in exposure to hazardous laser light.

Caution: Using different than described at the UL633 user guide, may result in unsafe operation.

COMPONENTS

aKeypad/LCD-Display

bHandle

cRotor with fan beam lens

dSunshade

eAxes-Alignment-Marks

fSighting Guides/Scope Mounts

gBattery door

hRubber Cover/Recharge Jack

i5/8” x 11 Tripod Mounts

jRubber Feet

kTurnable Legs

lPlus and Minus Battery Diagrams

2

Image 7
Contents Page Page Page Q104735 Rev. A01/12 Asia-Pacific North-Latin AmericaAfrica & Middle East EuropeTable of Contents Components For Your SafetyBatteries HOW to USE the Laser System Powering the LaserPowering the RC603 Recharging the BatteriesStandard Display Laser SetupFeatures and Functions Turning On/Off the laserZ-grade entering Digit Select mode Standard Features Z-grade entering Step and Go modePointing mode Using the Rotation modeUsing the Scan mode Manual modeSpecial Menu Features Menu Functions Radio controlled Automatic Grade Match Automatic PlaneLok modeWith the photocell on the bottom side Automatic Axis Alignment Manual Grade MatchActivating/Deactivating Standby mode Manual Spot Search modeCentering the Rotor Setting MenuService Start Reference CheckSpecial Features Vertical Setup Axis Automatic Spot Align RC603 Service menu offers additional features RF IR optionsRF Connectivity Axis Automatic Spot Match Axis Automatic Spot LokLine Scan PairingPairing Mask Mode Grade Entry Grade Display HI-Alert Information Set Password Password On/OffPairing the transmitter with receiver Pairing the transmitter with remote controlMask mode HI-alert Selection Grade EntryGrade Display Sensitivity SelectionUser Name Set PasswordPassword On/Off Password onChecking Calibration of the Y- and X-Axes CalibrationChecking Calibration of the Z-vertical Axis Error codes Description Solution TroubleshootingComponents SF601 SF601 User GuideSF601 Features and Functions Powering the SF601Using the SpotFinder SF601 for vertical UL applications SF601 Manual/Display Mode Protecting the Unit Cleaning and MaintenanceProtecting the Environment Spot Finder SF601 Technical DataRemote Control RC603 UL633Dayton, Ohio UL633 and RC603/SF601 Declaration of ConformityELECTRO-MAGNETIC Compatibility Trimble Kaiserslautern GmbH