Videk 2030 manual Introduction, Dot

Page 25

2.1 - Introduction

The VS 2030 comes pre-configured with Dynamic Optimization Technology (DOT), a revolutionary adaptive read technique that eliminates the need to manually set most individual parameters. From the moment you turn on your VS 2030, you are taking full advantage of the dual path 1.3 megapixel imager, the 400 MHz processor, and DOT.

DOT continuously adapts the resolution, illumination, and image field for optimized automatic symbology identification. DOT achieves decoding speeds for 2D codes that are similar to speeds usually only seen in 1D readers. VS 2030 units are able to read a wide range of symbology types and sizes, as well as a variety of printed media, within a wide range of environmental factors including light (natural or ambient lighting).

By defining if you are scanning large, small, or different sizes of multiple types of codes, types of sym- bologies), (1D or 2D) and densities of the codes, the VS 2030 offers options for set up that will maximize decoding speed.

The chart below shows options that will improve performance based on parameters listed in each box.

DOT

The VS 2030 is easily customizable; each trigger can be independently programmed for different behavior. With DOT, optimizing the VS 2030 is as simple as deciding which Field of View is best and what type and size of symbologies are being scanned.

Near Field (NF): The nearest field of the VS 2030’s two image fields. The Near Field has the highest resolu- tion (1024 x 640 DPI). It has an optimal focal point of 4” (101.6 mm) away from the lens of the reader. It has a maximum focal distance of 8.5” with a 3” field of view at the farthest point. It has an overall viewing angle of 21º by 12 º.

Save Settings

K11020 VisionSensor™ 2030 User Manual, Rev. E, Software ver. 3.1.1000, August 3, 2007 - 19

 

 

 

Image 25
Contents Part Number K11020, Rev. E, August 3 Laser/LED Radiation Statement of Agency ComplianceSave Settings Table of Contents UPC/EAN/JAN VS 2030 Programming Symbology Settings Appendix a Reader Specifications  Getting Started Introduction Unpacking Powering On/Off ReaderDescription of Button Function Keypad/Icon OverviewIcon Description Power IconsBatch Operation RS232 Batch Cable-Detect DefaultIntroduction RS232 ConsiderationsIntroduction Cabled OperationUSB Cable Installation Guide USB Virtual COM 1 Way Mode USB Keyboard Default USB DownloaderRS232 One Way Mode Save Settings RS232 Cable Installation GuideMode RS232 One Way Mode Baud RateStop Bits Default Data Bits Data Bits Default1200 2400 4800 9600 19200 38400 Default 115200 Even Odd None DefaultCabled 2 hours Cabled Always Default Cabled Reader Time Out SettingsRS232 Reader Feedback GuideTargeting and Reading Techniques To read a symbol with the VSImager Field of View and Resolution Decode Zone Removing and Attaching Handle Optimization and Trigger Programming DOT IntroductionGlobal Trigger Optimization Matrix Left Trigger Optimization Matrix Read Codes with Both Imagers DefaultLeft Trigger Programming Read with Near-Field Imager onlyRight Trigger Programming Right Trigger Optimization MatrixRead Code with Near-Field Imager only Handle Trigger Programming Handle Optimization MatrixContinuous Trigger Optimization Matrix Far Field Only On Off DefaultContinuous Scan Both Near & Far Field OnMotion Detection Scan Settings Continuous Scan SettingsSeconds Default VS 2030 Programming Symbology Settings Codabar Symbology Aztec SymbologyCode 11 Symbology Codablock F SymbologyCode 39 Symbology Codablock F On Codablock F Off DefaultCode 128 Symbology Code 93 SymbologyCode 93 On Default Code 93 Off Sample Trioptic CodeData Matrix Symbology Composite SymbologiesComposite On Composite Off Default Maxicode Symbology Interleaved 2 of 5 SymbologyMSI Plessy Symbology Matrix 2 of 5 SymbologyMSI Plessy On MSI Plessy Off Default Sample MSI Plessy NEC 2 of 5 On NEC 2 of 5 Off Default NEC 2 of 5 SymbologyPharmacode Postal Symbologies UK ID Tag On Default UK ID Tag Off Advanced Postal SymbologiesRSS Symbology QR Code SymbologyUPC/EAN/JAN Telepen SymbologyReader Feedback and Special Settings Off Default Low Medium Volume and Vibration SettingsCode Readability Index Vibrate On / Beep On Vibrate On / Beep OffReadability Index Output Disable Backlight Intensity SettingsLow Med Default High Laser Settings Backlight Timeout SettingsReader Power Off Settings Reader Settings Locked Reader Settings LockReader ID and Firmware Version Reader ID and FirmwareUS English Default US English Leading Time Stamp SettingsKeyboard Support No Leading French GermanAdvanced Decode Performance Continuous Illumination Enable Continuous IlluminationSet Targeting Zone Tolerances 100 125Medium Code Windowing Small Code Windowing WindowingLarge 2-Dimensional Codes 640 x 640 pixels Codes Enable Sxga 1024 x VGA & Megapixel SettingsEnable VGA 640 x Mirror DecodingAdding a Prefix or Suffix and Reader Text Commands Suffix Settings Prefix SettingsPrefix Comma Prefix Space Reader Text Commands Erase Prefix and Suffix SettingsReader Text Commands On Erase Prefix & Suffix DataVS 2030 Maintenance and Troubleshooting General Safety Information Reset Reader to Factory DefaultsLimited Warranty WarrantyTerms of Warranty Warranty Coverage and ProcedureGeneral VS 2030 Accessories TroubleshootingCleaning the VS 2030 Window VS 2030 MaintenanceTechnical Support and Returns Appendix a Reader Specifications Performance Characteristics Physical CharacteristicsUser Environment Appendix B Mechanical & Electrical Specifications Dimensions USB Connector Pin Out Diagram Pin DIN Connector Pin Out Diagram RS232 Connector Pin Out Diagram Appendix C Pharmacode Settings Pharmacode Settings Pharmacode Settings con’t Appendix D Factory Default Settings Symbology Defaults Default SettingsControl Setting Defaults Batch Mode Setting Defaults RS-232 Interface Setting DefaultsAppendix E Programming Codes Appendix E Table of Contents Left Trigger Optimization and Settings Global All Trigger Optimization and SettingsRight Trigger Optimization and Settings Handle Trigger Optimization and SettingsSymbologies Continous Trigger Optimization and SettingsCode 39 On Default Reader Feedback Symbol Readability IndexLaser Settings Backlight SettingsIllumination Settings Keypad VolumeReader Settings Locked Reader Text CommandsMiscellaneous Settings Targeting Zone TolerancesVS 2030 Programming Codes Batch Log Only Mode Batch Send & Log ModeSuffix Erase/None Default RS232 Interface Baud Rate Suffix Tab USB Keyboard Mode only RS232 Interface Baud RateRS232 Interface Baud RateVS 2030 Programming Codes Handle Trigger Optimization Continous Trigger Digit Digit & Strip from Result Code 39 Off Code 39 Enable 5 with Control Character Stripped Allow ALL Data Matrix Codes DefaultAllow only Programming Data Matirx Codes Postal Codes Postnet On Japan Post On ID Tag/S18D Off UK ID Tag On Default UK ID Tag Off QR Code Inverse On QR & Micro QR Code On QR Code On QR Code Off Default QR Code EnableRSS Expanded On UPC Off UPC Extension Off Backlight Intensity Low Vibrate On Beep On Vibrate On Beep OffBacklight Intensity High Backlight OffKeypad Volume High Default Reader Power Off 1 HourMirroring Off Default Continous IlluminationUS English ctrl + char Lockout Link Mode