INSTALLATION

A-2

 

 

 

SAFETY PRECAUTIONS

WARNING

Do not attempt to use this equipment until you have thoroughly read the engine manufacturer’s manual supplied with your welder. It includes important safety precautions, detailed engine starting, operating and maintenance instructions, and parts lists.

------------------------------------------------------------------------

ELECTRIC SHOCK can kill.

Do not touch electrically live parts or electrode with skin or wet clothing.

Insulate yourself from work and ground

Always wear dry insulating gloves.

------------------------------------------------------------------------

ENGINE EXHAUST can kill.

• Use in open, well ventilated areas or vent exhaust outside.

------------------------------------------------------------------------

MOVING PARTS can injure.

Do not operate with doors open or guards off.

Stop engine before servicing.

Keep away from moving parts.

------------------------------------------------------------------------

See additional warning information at front of this operator’s manual.

Only qualified personnel should install, use, or service this equipment.

LOCATION AND VENTILATION

The welder should be located to provide an unrestrict- ed flow of clean, cool air to the cooling air inlets and to avoid restricting the cooling air outlets. Also, locate the welder so that the engine exhaust fumes are prop- erly vented to an outside area.

CAUTION

DO NOT MOUNT OVER COMbUSTIbLE SURFACES Where there is a combustible surface directly under stationary or fixed electrical equipment, that surface should be covered with a steel plate at least .06”(1.6mm) thick, which should extend not less than 5.90”(150mm) beyond the equipment on all sides.

------------------------------------------------------------------------

STORING

1.Store the machine in a cool, dry place when it is not in use. Protect it from dust and dirt. Keep it where it can’t be accidentally damaged from con- struction activities, moving vehicles, and other hazards.

2.Drain the engine oil and refill with fresh 10W30 oil. Run the engine for about five minutes to cir- culate oil to all the parts. See the MAINTE- NANCE section of this manual for details on changing oil.

3.Remove the battery, recharge it, and adjust the electrolyte level. Store the battery in a dry, dark place.

STACKING

AIR VANTAGE® 500 CUMMINS machines cannot be stacked.

ANGLE OF OPERATION

To achieve optimum engine performance the Air Vantage 500 CUMMINS should be run in a level posi- tion. The maximum angle of operation for the VMAC Compressor and CUMMINS engine is 20 degrees continues in all directions and 30 degrees intermittent (less than 10 minutes). When operating the welder at an angle, provisions must be made for checking and maintaining the oil level at the normal (FULL) oil capacity. Also the effective fuel capacity will be slightly less than the specified 25 gal.(94.6 ltrs.).

AIR VANTAGE® 500 CUMMINS

Image 12
Contents Safety Depends on You 11651Safety California Proposition 65 WarningsIiSAFETY IiiSAFETY IiiIvSAFETY Précautions DE SûretéElectromagnetic Compatibility EMC Methods of Reducing Emissions Mains Supply Vii Please Examine Carton and Equipment For Damage ImmediatelyOn-Line Product Registration TAbLE of Contents TAbLE of Contents Installation Technical Specifications AIR Vantage 500 Cummins K2325-3Safety Precautions Location and VentilationStoring StackingHigh Temperature Operation LiftingHigh Altitude Operation TowingPRE-OPERATION Engine and COM- Pressor Service OILFuel USE Diesel Fuel only Fuel CAPAIR Cleaner Inlet Hood Muffler Outlet PipeSpark Arrestor Welding TerminalsRemote Control Auxiliary Power ReceptaclesSTANDbY Power Connections Company Connection of Lincoln ELEC- Tric Wire Feeders Connection of LN-15 to the AIR Vantage 500 CumminsAcross The-Arc Model Control Cable ModelConnection of the LN-25 to the AIR Vantage 500 Cummins Shut off welder before making any electrical con- nectionsOperation General DescriptionControls and Settings RUN Stop SwitchEngine Temperature Gauge Hour MeterBATTERY Charging Light Idler SwitchOIL Pressure Gauge ENGINE PROTECTIONWELD MODE SELECTOR SWITCH Welding Terminals SwitchWIRE FEEDER VOLTMETER SWITCH PIN ConnectorAIR Compressor Controls 24 Thru Engine Operation Starting the EngineCold Weather Starting Stopping the EngineWelder Operation Wire WELDING-CV ARC GougingTable b.3 Typical Current Ranges Auxiliary Power Operation Simultaneous Welding and AUXIL- Iary Power LoadsBOTH 1 and 3 Phase ParallelingAccessories Optional Field Installed AccessoriesTIG Options K2641-2 Four Wheeled STEERAbLE Yard TrailerMaintenance Compressor MaintenanceService Instructions Single- and Two-StageEngine Air CleanersFuel Filters Cooling SystemPreventing Electrical Damage Cleaning Gfci Receptacle Testing and RESET- Ting ProcedureWelder / Generator MAINTE- Nance Nameplates / Warning Decals MAIN- TenanceTROUbLESHOOTING PRObLEMS SymptomsPOSSIbLE Cause Recommended Course of ActionTROUbLESHOOTING Maintenance section of Authorized Field Service Facility Wiring Diagram Diagrams Engine Welders / K867 / K775 / LN-7 Connection Diagram To Work Electrode Cable To Wire Feed UnitDiagrams Diagrams Engine Welders / K867 / LN-8 Connection Diagram Diagrams Diagrams Diagrams Diagrams Diagrams Diagrams Dimension Print AIR Vantage 500 Cummins Precaucion Warnung

IM10065 specifications

Air Vent Inc's IM10065 is a notable product in the field of ventilation systems, designed to enhance airflow and maintain optimal indoor air quality. As part of Air Vent's commitment to innovative and effective ventilation solutions, the IM10065 model stands out due to its advanced features and technologies.

One of the primary characteristics of the IM10065 is its efficient design, tailored for use in various residential applications. This product is particularly effective in preventing moisture accumulation within attics, thereby mitigating potential mold growth and ensuring a healthier living environment. By promoting proper ventilation, it helps to regulate temperature and humidity, making it an essential component for any modern home.

The IM10065 employs a reliable polypropylene construction that ensures durability and longevity. This material is not only lightweight but also resistant to corrosion, rust, and weathering, making it suitable for a range of outdoor climates. The robust construction minimizes the risk of damage over time, ensuring that the ventilation system functions optimally throughout its lifespan.

An important aspect of the IM10065 is its installation flexibility. The device can be easily integrated into various roofing types, which simplifies the setup process for contractors and homeowners alike. Moreover, with its low profile design, the IM10065 blends seamlessly into the roofline, preserving the aesthetic appeal of residential properties.

Furthermore, the IM10065 features a unique baffle system that enhances airflow while reducing the chances of backdrafts or wind-driven rain entering the attic space. This innovative feature is pivotal in maintaining consistent airflow, which contributes to the overall energy efficiency of the home.

The IM10065 also includes mesh screening that effectively prevents insects and debris from entering the ventilation system. This protective measure ensures that the internal components remain clean and functional, thereby extending the lifespan of the ventilation system.

In summary, Air Vent Inc's IM10065 is a well-engineered product characterized by its durable materials, flexible installation options, and innovative design features. These attributes make it an excellent choice for homeowners seeking reliable ventilation solutions that promote healthier indoor environments while also contributing to energy efficiency and longevity. With its combination of quality construction and advanced technology, the IM10065 exemplifies the high standards set by Air Vent Inc in the ventilation industry.