Air Vent Inc IM10065 OIL Pressure Gauge, Engine Protection, BATTERY Charging Light, Idler Switch

Page 22

b-3

OPERATION

b-3

 

 

 

6. OIL PRESSURE GAUGE

The gauge displays the engine oil pressure when the engine is running.

7. ENGINE PROTECTION

The yellow engine protection light remains off with proper oil pressure and under normal oper- ating temperatures. If the light turns on, the engine protection system will stop the engine. Check for proper oil level and add oil if neces- sary. Check for loose or disconnected leads at the oil pressure sender located on the engine. The light will remain on when the engine has been shut down due to low oil pressure or over- temperature condition.

8. bATTERY CHARGING LIGHT

The yellow engine alternator light is off when bat- tery charging system is functioning normally. If light turns on the alternator or the voltage regula- tor may not be operating correctly. The light will remain on when the engine is stopped and the run/stop switch is in the run position.

9. IDLER SWITCH

Has two positions as follows:

A)In the “High” position , the engine runs at the high idle speed controlled by the governor.

B) In the “Auto”

/

position, the

idler operates as follows:

 

a. When switched from “High” to “Auto” or after starting the engine, the engine will operate at full speed for approximately 12 seconds and then go to low idle speed.

b. When the electrode touches the work or power is drawn for lights or tools (approximately 100 Watts minimum) the engine accelerates and operates at full speed.

c. When welding ceases and the AC power load is turned off, a fixed time delay of approximate- ly 12 seconds starts.

d. If the welding or AC power load is not restart- ed before the end of the time delay, the idler reduces the engine speed to low idle speed.

e. The engine will automatically return to high idle speed when the welding load or AC power load is reapplied.

Idler Operational exceptions

When the WELDING TERMINALS switch is in the “Remotely Controlled” position the idler will operate as follows:

a. When the triggering device (Amptrol, Arc Start Switch, etc.) is pressed the engine will acceler- ate and operate at full speed provided a weld- ing load is applied within approximately 12 seconds.

If the triggering device remains pressed but no welding load is applied within approximately 12 seconds the engine may return to low idle speed.

If the triggering device is released or welding ceases the engine will return to low idle speed after approximately 12 seconds.

WELDING CONTROLS (Items 10 through 19)

10. OUTPUT CONTROL:

The OUTPUT dial is used to preset the output voltage or current as displayed on the digital meters for the four welding modes. When in the

CC-STICK, DOWNHILL PIPE or CV-WIRE modes and when a remote control is connected to the 6-Pin or 14-Pin Connector, the auto-sens- ing circuit automatically switches the OUTPUT CONTROL from control at the welder to the remote control.

In the CV-WIRE mode, when the wire feeder control cable is connected to the 14-Pin Connector, the auto-sensing circuit automatically makes OUTPUT CONTROL inactive and the wire feeder voltage control active.

When in the DOWNHILL PIPE mode and when a remote control is connected to the 6-Pin or 14- Pin connector, the output control is used to set the maximum current range of the remote.

EXAMPLE: When the OUTPUT CONTROL on the welder is set to 200 amps the current range on the remote control will be 40-200 amps, rather than the full 40-300 amps. Any current range that is less than the full range provides finer current resolution for more fine tuning of the output.

When in the TOUCH START TIG mode and when a Amptrol is connected to the 6-Pin Connector, the OUTPUT dial is used to set the maximum current range of the CURRENT CON- TROL of the Amptrol.

AIR VANTAGE® 500 CUMMINS

Image 22
Contents Safety Depends on You 11651Safety California Proposition 65 WarningsIiSAFETY IiiSAFETY IiiIvSAFETY Précautions DE SûretéElectromagnetic Compatibility EMC Methods of Reducing Emissions Mains Supply Please Examine Carton and Equipment For Damage Immediately ViiOn-Line Product Registration TAbLE of Contents TAbLE of Contents Installation Technical Specifications AIR Vantage 500 Cummins K2325-3Storing Safety PrecautionsLocation and Ventilation StackingHigh Altitude Operation High Temperature OperationLifting TowingFuel USE Diesel Fuel only PRE-OPERATION Engine and COM- Pressor ServiceOIL Fuel CAPSpark Arrestor AIR Cleaner Inlet HoodMuffler Outlet Pipe Welding TerminalsAuxiliary Power Receptacles Remote ControlSTANDbY Power Connections Company Across The-Arc Model Connection of Lincoln ELEC- Tric Wire FeedersConnection of LN-15 to the AIR Vantage 500 Cummins Control Cable ModelConnection of the LN-25 to the AIR Vantage 500 Cummins Shut off welder before making any electrical con- nectionsOperation General DescriptionEngine Temperature Gauge Controls and SettingsRUN Stop Switch Hour MeterOIL Pressure Gauge BATTERY Charging LightIdler Switch ENGINE PROTECTIONWIRE FEEDER VOLTMETER SWITCH WELD MODE SELECTOR SWITCHWelding Terminals Switch PIN ConnectorAIR Compressor Controls 24 Thru Cold Weather Starting Engine OperationStarting the Engine Stopping the EngineWelder Operation ARC Gouging Wire WELDING-CVTable b.3 Typical Current Ranges BOTH 1 and 3 Phase Auxiliary Power OperationSimultaneous Welding and AUXIL- Iary Power Loads ParallelingTIG Options AccessoriesOptional Field Installed Accessories K2641-2 Four Wheeled STEERAbLE Yard TrailerMaintenance Compressor MaintenanceService Instructions Single- and Two-StageEngine Air CleanersCooling System Fuel FiltersPreventing Electrical Damage Welder / Generator MAINTE- Nance CleaningGfci Receptacle Testing and RESET- Ting Procedure Nameplates / Warning Decals MAIN- TenanceTROUbLESHOOTING POSSIbLE PRObLEMSSymptoms Cause Recommended Course of ActionTROUbLESHOOTING Maintenance section of Authorized Field Service Facility Wiring Diagram Diagrams Engine Welders / K867 / K775 / LN-7 Connection Diagram To Work Electrode Cable To Wire Feed UnitDiagrams Diagrams Engine Welders / K867 / LN-8 Connection Diagram Diagrams Diagrams Diagrams Diagrams Diagrams Diagrams Dimension Print AIR Vantage 500 Cummins Precaucion Warnung

IM10065 specifications

Air Vent Inc's IM10065 is a notable product in the field of ventilation systems, designed to enhance airflow and maintain optimal indoor air quality. As part of Air Vent's commitment to innovative and effective ventilation solutions, the IM10065 model stands out due to its advanced features and technologies.

One of the primary characteristics of the IM10065 is its efficient design, tailored for use in various residential applications. This product is particularly effective in preventing moisture accumulation within attics, thereby mitigating potential mold growth and ensuring a healthier living environment. By promoting proper ventilation, it helps to regulate temperature and humidity, making it an essential component for any modern home.

The IM10065 employs a reliable polypropylene construction that ensures durability and longevity. This material is not only lightweight but also resistant to corrosion, rust, and weathering, making it suitable for a range of outdoor climates. The robust construction minimizes the risk of damage over time, ensuring that the ventilation system functions optimally throughout its lifespan.

An important aspect of the IM10065 is its installation flexibility. The device can be easily integrated into various roofing types, which simplifies the setup process for contractors and homeowners alike. Moreover, with its low profile design, the IM10065 blends seamlessly into the roofline, preserving the aesthetic appeal of residential properties.

Furthermore, the IM10065 features a unique baffle system that enhances airflow while reducing the chances of backdrafts or wind-driven rain entering the attic space. This innovative feature is pivotal in maintaining consistent airflow, which contributes to the overall energy efficiency of the home.

The IM10065 also includes mesh screening that effectively prevents insects and debris from entering the ventilation system. This protective measure ensures that the internal components remain clean and functional, thereby extending the lifespan of the ventilation system.

In summary, Air Vent Inc's IM10065 is a well-engineered product characterized by its durable materials, flexible installation options, and innovative design features. These attributes make it an excellent choice for homeowners seeking reliable ventilation solutions that promote healthier indoor environments while also contributing to energy efficiency and longevity. With its combination of quality construction and advanced technology, the IM10065 exemplifies the high standards set by Air Vent Inc in the ventilation industry.