Air Vent Inc IM10065 manual Electromagnetic Compatibility EMC

Page 6

v

SAFETY

v

 

 

 

Electromagnetic Compatibility (EMC)

Conformance

Products displaying the CE mark are in conformity with European Community Council Directive of 15 Dec 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility, 2004/108/EC. It was manufactured in conformity with a national standard that implements a harmonized standard: EN 60974-10 Electromagnetic Compatibility (EMC) Product Standard for Arc Welding Equipment. It is for use with other Lincoln Electric equipment. It is designed for industrial and professional use.

Introduction

All electrical equipment generates small amounts of electromagnetic emission. Electrical emission may be transmitted through power lines or radiated through space, similar to a radio transmitter. When emissions are received by other equipment, electrical interference may result. Electrical emissions may affect many kinds of electrical equipment; other nearby welding equipment, radio and TV reception, numerical controlled machines, telephone systems, computers, etc. Be aware that interference may result and extra precautions may be required when a welding power source is used in a domestic establishment.

Installation and Use

The user is responsible for installing and using the welding equipment according to the manufacturer’s instructions. If electromagnetic disturbances are detected then it shall be the responsibility of the user of the welding equipment to resolve the situation with the technical assistance of the manufacturer. In some cases this remedial action may be as simple as earthing (grounding) the welding circuit, see Note. In other cases it could involve construction of an electromagnetic screen enclosing the power source and the work complete with associated input filters. In all cases electromagnetic disturbances must be reduced to the point where they are no longer troublesome.

Note: The welding circuit may or may not be earthed for safety reasons according to national codes. Changing the earthing arrangements should only be authorized by a person who is compe- tent to access whether the changes will increase the risk of injury, e.g., by allowing parallel welding current return paths which may damage the earth circuits of other equipment.

Assessment of Area

Before installing welding equipment the user shall make an assessment of potential electromagnetic prob- lems in the surrounding area. The following shall be taken into account:

a)other supply cables, control cables, signaling and telephone cables; above, below and adjacent to the welding equipment;

b)radio and television transmitters and receivers;

c)computer and other control equipment;

d)safety critical equipment, e.g., guarding of industrial equipment;

e)the health of the people around, e.g., the use of pacemakers and hearing aids;

f)equipment used for calibration or measurement

g)the immunity of other equipment in the environment. The user shall ensure that other equipment being used in the environment is compatible. This may require additional protection measures;

h)the time of day that welding or other activities are to be carried out.

AIR VANTAGE® 500 CUMMINS

Image 6
Contents Safety Depends on You 11651Safety California Proposition 65 WarningsIiSAFETY IiiSAFETY IiiIvSAFETY Précautions DE SûretéElectromagnetic Compatibility EMC Methods of Reducing Emissions Mains Supply Vii Please Examine Carton and Equipment For Damage ImmediatelyOn-Line Product Registration TAbLE of Contents TAbLE of Contents Installation Technical Specifications AIR Vantage 500 Cummins K2325-3Storing Safety PrecautionsLocation and Ventilation StackingHigh Altitude Operation High Temperature OperationLifting TowingFuel USE Diesel Fuel only PRE-OPERATION Engine and COM- Pressor ServiceOIL Fuel CAPSpark Arrestor AIR Cleaner Inlet HoodMuffler Outlet Pipe Welding TerminalsRemote Control Auxiliary Power ReceptaclesSTANDbY Power Connections Company Across The-Arc Model Connection of Lincoln ELEC- Tric Wire FeedersConnection of LN-15 to the AIR Vantage 500 Cummins Control Cable ModelConnection of the LN-25 to the AIR Vantage 500 Cummins Shut off welder before making any electrical con- nectionsOperation General DescriptionEngine Temperature Gauge Controls and SettingsRUN Stop Switch Hour MeterOIL Pressure Gauge BATTERY Charging LightIdler Switch ENGINE PROTECTIONWIRE FEEDER VOLTMETER SWITCH WELD MODE SELECTOR SWITCHWelding Terminals Switch PIN ConnectorAIR Compressor Controls 24 Thru Cold Weather Starting Engine OperationStarting the Engine Stopping the EngineWelder Operation Wire WELDING-CV ARC GougingTable b.3 Typical Current Ranges BOTH 1 and 3 Phase Auxiliary Power OperationSimultaneous Welding and AUXIL- Iary Power Loads ParallelingTIG Options AccessoriesOptional Field Installed Accessories K2641-2 Four Wheeled STEERAbLE Yard TrailerMaintenance Compressor MaintenanceService Instructions Single- and Two-StageEngine Air CleanersFuel Filters Cooling SystemPreventing Electrical Damage Welder / Generator MAINTE- Nance CleaningGfci Receptacle Testing and RESET- Ting Procedure Nameplates / Warning Decals MAIN- TenanceTROUbLESHOOTING POSSIbLE PRObLEMSSymptoms Cause Recommended Course of ActionTROUbLESHOOTING Maintenance section of Authorized Field Service Facility Wiring Diagram Diagrams Engine Welders / K867 / K775 / LN-7 Connection Diagram To Work Electrode Cable To Wire Feed UnitDiagrams Diagrams Engine Welders / K867 / LN-8 Connection Diagram Diagrams Diagrams Diagrams Diagrams Diagrams Diagrams Dimension Print AIR Vantage 500 Cummins Precaucion Warnung

IM10065 specifications

Air Vent Inc's IM10065 is a notable product in the field of ventilation systems, designed to enhance airflow and maintain optimal indoor air quality. As part of Air Vent's commitment to innovative and effective ventilation solutions, the IM10065 model stands out due to its advanced features and technologies.

One of the primary characteristics of the IM10065 is its efficient design, tailored for use in various residential applications. This product is particularly effective in preventing moisture accumulation within attics, thereby mitigating potential mold growth and ensuring a healthier living environment. By promoting proper ventilation, it helps to regulate temperature and humidity, making it an essential component for any modern home.

The IM10065 employs a reliable polypropylene construction that ensures durability and longevity. This material is not only lightweight but also resistant to corrosion, rust, and weathering, making it suitable for a range of outdoor climates. The robust construction minimizes the risk of damage over time, ensuring that the ventilation system functions optimally throughout its lifespan.

An important aspect of the IM10065 is its installation flexibility. The device can be easily integrated into various roofing types, which simplifies the setup process for contractors and homeowners alike. Moreover, with its low profile design, the IM10065 blends seamlessly into the roofline, preserving the aesthetic appeal of residential properties.

Furthermore, the IM10065 features a unique baffle system that enhances airflow while reducing the chances of backdrafts or wind-driven rain entering the attic space. This innovative feature is pivotal in maintaining consistent airflow, which contributes to the overall energy efficiency of the home.

The IM10065 also includes mesh screening that effectively prevents insects and debris from entering the ventilation system. This protective measure ensures that the internal components remain clean and functional, thereby extending the lifespan of the ventilation system.

In summary, Air Vent Inc's IM10065 is a well-engineered product characterized by its durable materials, flexible installation options, and innovative design features. These attributes make it an excellent choice for homeowners seeking reliable ventilation solutions that promote healthier indoor environments while also contributing to energy efficiency and longevity. With its combination of quality construction and advanced technology, the IM10065 exemplifies the high standards set by Air Vent Inc in the ventilation industry.