Sterling operating instructions SSV 05/R Connecting the compressed-air supply

Page 18

SSV 05/R

2.4. Connecting the compressed-air supply

Check compressed-air piping for correct installa- tion and assembly.

Check fittings, length and quality of the hose con- nections for agreement with requirements.

Check all compressed-air lines for leakages.

You need a compressed-air supply with 5 - 6 bar system (72.52-87.02 PSI) overpressure. The air should be free from oil and water, if possible.

Connect the compressed-air hose, which is part of the supply, to the injector tube and to the con- trol and maintenance unit. To this end, the com- pressed-air hose is firmly pressed into the con- necting sockets.

Connect the control and maintenance unit to the compressed-air supply (max. input pressure 10 bar (145.03 PSI) system overpressure).

Set the pressure on the pressure reducer at 5 - 6 bar (72.52-87.02 PSI).

F

Maximum input pressure 10 bar (145.03 PSI) (system overpressure).

Maximum output pressure 6 bar (87.02 PSI).

SM4-605

Installation instructions 17

Image 18
Contents Operating Instructions Single Conveyor Unit SSV 05/R Sterling Material ProcessingTechnical service SSV 05/R Sterling Material ProcessingEdition 08/99 SSV 05/R Parts and Service Department Table of contents SSV 05/R Technical data Safety instructions Safety instructionsSSV 05/R SSV 05/R Explanations and information SSV 05/R For your safety SSV 05/R SSV 05/R SSV 05/R For the safety of the units Installation instructions SSV 05/R General information SSV 05/R Installing the conveyor hopper SSV 05/R Installing the control and maintenance unit SSV 05/R Connecting the compressed-air supply SSV 05/R Electrical connection Functional description Control and maintenance unit SSV 05/R Method of functioningSet-up Filling level too low Basic setting of the filling level in the conveyor hopperSSV 05/R Preparations Filling level too highSet-up Maintenance SSV 05/R SSV 05/R Maintenance intervals SSV 05/R Cleaning/replacing the filter cartridge DisassemblySSV 05/R Assembly Adjusting the level probeSSV 05/R Trouble-shooting Problem Remedy Test stepsTechnical data SSV 05/R Dimension sheet SSV 05/R Spare parts list Maintenance and control unit Designation ID-No SSV 05/R Pos Designation ID-No