3.1. Method of functioning
The single conveyor unit works according to the venturi principle. An external
Aventuri meter (A) is integrated in the injector tube. The venturi meter aspirates the material in the lower part of the tube (C) and then conveys the material into the conveyor hopper by means of compressed air in the upper part (B). In the hopper loader, the material is separated from the air.
The filling level in the conveyor hopper is moni- tored and controlled by means of a level probe.
A
B
C
3.2. Control and maintenance unit
The unit is switched on and off at the control and maintenance unit.
On the pressure reducer, the operating pres- |
|
sure is adjusted. A water separator is inte- | 0 |
| 1 |
grated. |
|
Functional description 20