5.4. Trouble-shooting

 

Problem

Remedy

The unit is not conveying

 

and is not active

a, b, g, h

The unit is not conveying;

 

the compressed-air valve is switched

 

when the device is switched on

c, f

The unit is not conveying,

 

the compressed air is flowing audibly

c, d, e, f, i, j, k

The unit is overfilled

g, l, m

The unit is not filled properly

c, d, e, f, i, j, k, l

Test steps

 

a)Check whether the unit is switched on.

b)Check whether the mains connector is connected and mains voltage is pres- ent.

c)Check whether sufficient compressed air is available.

d)Check whether the injector tube is inserted in the material.

e)Check whether the compressed-air hose is properly connected to the injector tube.

f)Check whether the compressed-air hose is properly connected to the mainte- nance unit.

g)Check whether the level probe is properly adjusted.

h)Check whether the cable of the level probe is properly connected.

i)Check whether the filter is clogged.

j)Check whether the sieve is clogged.

k)Check whether the conveyor hose is properly connected.

l)Check whether the compressed-air supply is properly adjusted.

SM4-605

Maintenance 29

Image 30
Contents Operating Instructions Single Conveyor Unit SSV 05/R Sterling Material ProcessingTechnical service SSV 05/R Sterling Material ProcessingEdition 08/99 SSV 05/R Parts and Service Department Table of contents SSV 05/R Technical data Safety instructions Safety instructionsSSV 05/R SSV 05/R Explanations and information SSV 05/R For your safety SSV 05/R SSV 05/R SSV 05/R For the safety of the units Installation instructions SSV 05/R General information SSV 05/R Installing the conveyor hopper SSV 05/R Installing the control and maintenance unit SSV 05/R Connecting the compressed-air supply SSV 05/R Electrical connection Functional description Control and maintenance unit SSV 05/R Method of functioningSet-up Filling level too low Basic setting of the filling level in the conveyor hopperSSV 05/R Preparations Filling level too highSet-up Maintenance SSV 05/R SSV 05/R Maintenance intervals SSV 05/R Cleaning/replacing the filter cartridge DisassemblySSV 05/R Assembly Adjusting the level probeSSV 05/R Trouble-shooting Problem Remedy Test stepsTechnical data SSV 05/R Dimension sheet SSV 05/R Spare parts list Maintenance and control unit Designation ID-No SSV 05/R Pos Designation ID-No